Immunity and Emissions Testing There are 40 products.

per page
Showing 1 - 12 of 40 items
    • Suitable for EUT Approx. (200 x 200 x 150mm) (7.87 x 7.87 x 5.90in.)
    • Max EUT dimension for uniform-area: (83 x 83 x 83mm) (3.26 x 3.26 x 3.26in.)
    • Emissions and immunity testing in a single, shielded environment
    • Meets basic standard: IEC/EN 61000-4-20
    • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
    • Meets standards for immunity testing: EN 60118-13
    • Ideal for design qualification and pre-certification
    Request Quote/More Info
    • Max EUT Size: 200 x 200 x 150 mm (7.87 x 7.87 x 5.9)in.
    • Max EUT dimension for uniform-area: (83 x 83 x 83 mm) (3.26 x 3.26 x 3.26in.)
    • Test cell with special opening to test integrated circuits on approx. 45 mm septum height
    • Meets IEC/EN 61000-4-20, SAE J1752/3, IEC 62132-2 and IEC 61967-2
    • For 100 Watts input power
    • Excellent VSWR up to 18 GHz
    Request Quote/More Info
    • Max (620 x 620 x 490mm) (24.40 x 24.40 x 19.29in.)
    • Max EUT dimension for uniform-area: (250 x 250 x 250mm) (9.84 x 9.84 x 9.84in.)
    • Emissions and immunity testing in a single, shielded environment
    • Meets basic standard: IEC/EN 61000-4-20
    • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
    • Meets standards for immunity testing: EN 60118-13
    • Ideal for design qualification and pre-certification
    Request Quote/More Info
    • Max EUT Size: (740 x 740 x 660mm) (29.13 x 29.13 x 25.98in.)
    • Max EUT dimension for uniform-area: (333 x 333 x 333mm) (13.11 x 13.11 x 13.11in.)
    • Emissions and immunity testing in a single, shielded environment
    • Meets basic standard: IEC/EN 61000-4-20
    • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
    • Meets standards for immunity testing: EN 60118-13
    • Ideal for design qualification and pre-certification
    Request Quote/More Info
    • Max EUT Size: (930 x 930 x 830mm) (36.31 x 36.61 x 32.67in.)
    • EUT dimension for uniform-area: (416 x 416 x 416mm) (16.37 x 16.37 x 16.37in.)
    • Emissions and immunity testing in a single, shielded environment
    • Meets basic standard: IEC/EN 61000-4-20
    • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
    • Meets standards for immunity testing: EN 60118-13
    • Ideal for design qualification and pre-certification
    Request Quote/More Info
    • Max EUT Size: (1110 x 1110 x 990mm) (43.7 x 43.7 x 38.97in.)
    • Max EUT dimension for uniform-area: (500 x 500 x 500mm) (19.68 x 19.68 x 19.68in.)
    • Emissions and immunity testing in a single, shielded environment
    • Meets basic standard: IEC/EN 61000-4-20
    • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
    • Meets standards for immunity testing: EN 60118-13
    • Ideal for design qualification and pre-certification
    Request Quote/More Info
    • Max EUT Size: (1500 x 1500 x 1320mm) (59.05 x 59.05 x 51.96in.)
    • Max EUT dimension for uniform-area: (666 x 666 x 666mm) (26.22 x 26.22 x 26.22in.)
    • Emissions and immunity testing in a single, shielded environment
    • Meets basic standard: IEC/EN 61000-4-20
    • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
    • Meets standards for immunity testing: EN 60118-13
    • Ideal for design qualification and pre-certification
    Request Quote/More Info
    • Broad Frequency Range of 10 KHz to 100 MHz
    • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 8 to 30 dB
    • Max Input Power: 100 Watts
    • Connector: N-type, Female
    • Aperture: 1.5" (38mm)
    • Diameter: 4.25" (108mm)
    • Weight: 4.2 lbs (1.9 kg)
    Request Quote/More Info
    • Broad Frequency Range of 1 MHz - 500 MHz
    • Measures currents on 50 Hz, 60 Hz and 400 Hz powerlines
    • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 4 to 16 dB
    • Transfer Impedance: 16 to 31 dBW
    • Max Input Power: 200 Watts
    Request Quote/More Info
    • Broad High Frequency Response: 5 MHz - 1 GHz
    • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
    • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 5 to 30 dB
    • Max Input Power: 50 Watts
    • Mas Current: 30 Amps
    Request Quote/More Info
    • In Stock, Calibrated and Ready to Ship
    • Prices are on a Per Month Basis
    • Broad High Frequency Response: 300 kHz - 1 GHz
    • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
    • Measures currents on 50 Hz, 60 Hz and 400 Hz power lines
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe
    $195.00
    Request Quote/More Info
    • Broad High Frequency Response: 1 MHz - 400 MHz
    • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
    • Measures currents on 50 Hz, 60 Hz and 400 Hz power lines
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 4 to 22 dB
    • Max Input Power: 100 Watts CS
    Request Quote/More Info
Showing 1 - 12 of 40 items