Anechoic Chambers & GTEM's

The EMC Shop stocks GTEM's and manages anechoic chamber installs for radiated emissions and immunity/susceptibility testing.

Get Application Support, Pricing, Lead Time and More: Contact Form



Transport and install of anechoic chambers and GTEM's is a tough task. The EMC Shop will handle the logistic in shipping, install and validation/calib...

The EMC Shop stocks GTEM's and manages anechoic chamber installs for radiated emissions and immunity/susceptibility testing.

Get Application Support, Pricing, Lead Time and More: Contact Form



Transport and install of anechoic chambers and GTEM's is a tough task. The EMC Shop will handle the logistic in shipping, install and validation/calibration of the chambers for accurate RF testing.



Precompliance GTEM & Anechoic Chamber Considerations

  • GTEM 250: Easy transport and setup for DUT sizes 8" by 6" by 6"
  • TEM CELLS: Efficient method for radiated testing at lower frequencies
  • Anechoic Chambers: Very in-depth project, this engineering project will take several months and hundreds of thousands or millions of dollars.

More

Anechoic Chambers & GTEM's There are 23 products.

per page
Showing 1 - 12 of 23 items
  • Pricing Includes:

    • Shipment to any of the lower 48 States
    • Onsite Assembly and Calibration (2-3 Days)
    • 1-Year Warranty
    • Max EUT Size: (1166 x 1166 x 1166 mm) (45.90 x 45.90 x 45.90in.)
    • Built in Turntable with 2 Axis Rotation
    • Radiated Emissions: 30 MHz - 1 GHz
    • Radiated Immunity: DC - 18 GHz
    • Up to 75 kW Input CW Power
    • Up to 1100 V/m CW Field Strength
    • IEC/EN 61000-4-20
    $64,000.00
    Sold Out - Inquire for Alternatives
    Request Quote/More Info
    • Max EUT Size: (200 x 200 x 150mm) (7.87 x 7.87 x 5.90in.)
    • IEC/EN 61000-4-20 (CEI 210-78)
    • both radiated emission and immunity measurements
    • Testing in Transverse Electromagnetic (TEM) Waveguides
    • (Equipment Under Test) up to a frequency range of 20 GHz
    $17,500.00
    1-2 Weeks
    Request Quote/More Info
    • Hand made in the US wood table with built in Coupling Plane
    • Ground plate wih easy access built in screws
    • Suitable for Table top and floor standing DUT.
    • .1m insulating support supplied
    $4,750.00
    In Stock
    Request Quote/More Info
    • Setup and install available from The EMC Shop
    • Long Term Rentals & Leases Available
    • Electric fields= 100 db from 14 KHz to 10 MHz
    • Plane waves= 100 db from 100 MHz to 10 GHz
    • 208V 3ph AC Power filters and fire sprinkler adapter
    • 12' by 20' by 8'
    • 6 month warranty
    4-6 Weeks
    Request Quote/More Info
    • Suitable for EUT Approx. (200 x 200 x 150mm) (7.87 x 7.87 x 5.90in.)
    • Max EUT dimension for uniform-area: (83 x 83 x 83mm) (3.26 x 3.26 x 3.26in.)
    • Emissions and immunity testing in a single, shielded environment
    • Meets basic standard: IEC/EN 61000-4-20
    • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
    • Meets standards for immunity testing: EN 60118-13
    • Ideal for design qualification and pre-certification
    4-6 Weeks
    Request Quote/More Info
    • Max EUT Size: 200 x 200 x 150 mm (7.87 x 7.87 x 5.9)in.
    • Max EUT dimension for uniform-area: (83 x 83 x 83 mm) (3.26 x 3.26 x 3.26in.)
    • Test cell with special opening to test integrated circuits on approx. 45 mm septum height
    • Meets IEC/EN 61000-4-20, SAE J1752/3, IEC 62132-2 and IEC 61967-2
    • For 100 Watts input power
    • Excellent VSWR up to 18 GHz
    4-6 Weeks
    Request Quote/More Info
    • Max EUT Size: (410 x 410 x 310mm) (16.14 x 16.14 x 12.20in.)
    • MAX EUT dimension for uniform-area: (167 x 167 x 167mm) (6.57 x 6.57 x 6.57in.)
    • Emissions and immunity testing in a single, shielded environment
    • Meets basic standard: IEC/EN 61000-4-20
    • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
    • Meets standards for immunity testing: EN 60118-13
    • Ideal for design qualification and pre-certification
    4-6 Weeks
    Request Quote/More Info
    • Max (620 x 620 x 490mm) (24.40 x 24.40 x 19.29in.)
    • Max EUT dimension for uniform-area: (250 x 250 x 250mm) (9.84 x 9.84 x 9.84in.)
    • Emissions and immunity testing in a single, shielded environment
    • Meets basic standard: IEC/EN 61000-4-20
    • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
    • Meets standards for immunity testing: EN 60118-13
    • Ideal for design qualification and pre-certification
    4-6 Weeks
    Request Quote/More Info
    • Max EUT Size: (740 x 740 x 660mm) (29.13 x 29.13 x 25.98in.)
    • Max EUT dimension for uniform-area: (333 x 333 x 333mm) (13.11 x 13.11 x 13.11in.)
    • Emissions and immunity testing in a single, shielded environment
    • Meets basic standard: IEC/EN 61000-4-20
    • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
    • Meets standards for immunity testing: EN 60118-13
    • Ideal for design qualification and pre-certification
    4-6 Weeks
    Request Quote/More Info
    • Max EUT Size: (930 x 930 x 830mm) (36.31 x 36.61 x 32.67in.)
    • EUT dimension for uniform-area: (416 x 416 x 416mm) (16.37 x 16.37 x 16.37in.)
    • Emissions and immunity testing in a single, shielded environment
    • Meets basic standard: IEC/EN 61000-4-20
    • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
    • Meets standards for immunity testing: EN 60118-13
    • Ideal for design qualification and pre-certification
    4-6 Weeks
    Request Quote/More Info
    • Max EUT Size: (1110 x 1110 x 990mm) (43.7 x 43.7 x 38.97in.)
    • Max EUT dimension for uniform-area: (500 x 500 x 500mm) (19.68 x 19.68 x 19.68in.)
    • Emissions and immunity testing in a single, shielded environment
    • Meets basic standard: IEC/EN 61000-4-20
    • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
    • Meets standards for immunity testing: EN 60118-13
    • Ideal for design qualification and pre-certification
    4-6 Weeks
    Request Quote/More Info
    • Max EUT Size: (1320 x 1320 x 1160mm) (51.96 x 51.96 x 45.66in.)
    • Max EUT dimension for uniform-area: (583 x 583 x 583mm) (22.95 x 22.95 x 22.95in.)
    • Emissions and immunity testing in a single, shielded environment
    • Meets basic standard: IEC/EN 61000-4-20
    • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
    • Meets standards for immunity testing: EN 60118-13
    • Ideal for design qualification and pre-certification
    4-6 Weeks
    Request Quote/More Info
Showing 1 - 12 of 23 items