Noiseken
SKU: sku-800
Noiseken LSS-15AX Series Lightning Surge Simulator up to 15kV
Weight: 200 kg.Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling: AC/DC lines CDN, and Telecom lines CDNDimensions: 555 X 1250 X 790 mmImpedance: 2 OhmMains & EUT Connections: 4mm banana plugPhase synchronization: 0°-360°, 1°step or randomPolarity: Positive, Negative, AlternatePulse current (short circuit): 15kV/7500APulse repetition: 20 secPulse voltage (open circuit): 15kV/7500AStandards Met: IEC 61000-4-5$0.00 -
Schloder
SKU: sku-783
Schloder CWG 1500 Surge Generator, 4.4 kV, 2.2 kA, EN/IEC 61000-4-5
Condition (5-10 Scale): 9Warranty: 6 MonthsCalibration: Fresh w/ Data at Time of OrderTest standard: IEC 61000-4-5Accessorries: CompleteInput: 120VAC/1PHPhase synchronization: 0 - 359°, step 1° net sync. triggeringPolarity: pos / neg / alternatePulse current (short circuit): 0.1 - 2.2 kAPulse voltage (open circuit): 0.2 - 4.4 kVTest duration: 10 - 990 sec$7,950.001 LEFT -
EM Test
SKU: sku-747
EM Test CSS 500N10 Current Surge Generator, 8/20us Up To 10ka
Weight: approx. 66 lbs.Coupling: N/ADimensions: 19"/6HU,Polarity: positive / negative / alternatePulse current (short circuit): 0.4kA to 10kA +/-10%Pulse voltage (open circuit): 250V to 6,000V +/-10%, Step width 50VRepetition time: Max. 10 pulses per minute, depending on the charging voltage$0.00 -
Thermo Keytek
SKU: sku-583
Keytek (Thermo Fisher) CE Master for EFT, Surge, PQF
Dips, Interrupts & Variations: 70%, 40%Polarity: positive / negative / alternateWeight: 29kg (64 lbs)Air Discharge Voltage Range: 500V - 8.8kVBurst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Burst frequency: 1-100kHzCombination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Contact Discharge Voltage Range: 500V - 4.4kVCoupling: externalDimensions: Height 17.8cm (7.0in) Width 47cm (18.5in) Depth 56cm (22in)Dips, Interrupts & Variations-2: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29Electrostatic Discharge: Pulse conforms to IEC 61000-4-2 edition 2Magnetic Field Strength: 0.5A/m - 4A/m (IEC 1000-4-8)Outputs: Single Shot, 1 pulse/sec and 20 pulses/secPolarity-2: positive / negative / alternatePulse amplitude: more than 250Amps @ 120V, more than 500Amps @ 240VPulse current (short circuit): 125A - 1.25kAPulse voltage (open circuit): 250V - 2.5kVSupply Voltage: Input Voltage 90 - 250VACTest duration: 1µs - 5µsUvar with step transformer: 70%, 40%$0.00 -
Haefely
SKU: sku-444
Haefely PCD 130 3 Phase Coupling/Decoupling Network for PSURGE 8000
Weight: 69 kg (net weight)Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling: 3 Phase - 32 Amps, 690 VACDimensions: 45 x 50 x 57 cm (W x H x D)General Data: Technical DetailsPhase synchronization: 1° stepsPolarity: pos / negPulse current (short circuit): 32A RMSPulse voltage (open circuit): 690V RMS (Phase-Phase) 110V DCStandards Met: IEC 61000-4-5 Ed. 1 & 2 and ANSI C62.41 and C62.45$0.00 -
Teseq
SKU: sku-346
Teseq CDN 118-T4 Coupling Decoupling Network set for 1.2/50 µs and 10/700 µs Surge Pulses on 1 or 2 twisted pairs
Weight: 19.5 kg (43 lbs)Application/Test Type: 1.2/50 μs (2 ohms) and 10/700 μs (15 ohms) pulse up to 6.6 kV line to ground, 3 kV line to line (Pulse frequency: 3 per minute)Current Rating: 0.5 AmpsDecoupling chokes 1 kHz: 20 mH nominalDimensions: 335 x 232 x 180mmMains & EUT Connections: 4 mm safety banana; Fischer 103Ohmic resistance per path: 3 ΩSeries resistor: in relation to the selected pulse coupling networkTransmission 3 dB BW: 250 kHzVoltage Rating: 250 Volts AC/DC$0.00 -
Thermo Keytek
SKU: sku-311
Used Thermo Fisher Keytek ECAT Surge & Burst/EFT Simulator System
Coupling: Model E4551 - Single Phase 15 AmpsTest duration: 1.0ms to 20ms; 1.0ms resolution or 1 to 200 pulsesBurst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Burst frequency: Adjustable from 1kHz to 1MHz up to 4.4kVBurst time: 1 to 360 sec.; 1 sec. resolution 1 to 240 min.; 1 min. resolution 1 to 24 hours; 1 hour resolutionCombination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling-2: 1 PH / 15 (16) AmpsPhase synchronization: ±15° with optional coupler/decouplerPolarity: Positive, negative, alternatingPulse amplitude: 200V to 4.4kV (5V StepsPulse current (short circuit): 8/20µs, 100A - 3.3kA -0 +10% with 2 ohm effective source impedance.Pulse repetition: 1 shot/12 seconds; Rise Time Tolerance ±30% for voltage; ±20% for currentPulse voltage (open circuit): 1.2/50µs, 200V - 6.6kV -5 +10% in 1 volt stepsRepetition time: Adjustable from 300ms to 5s; 1ms resolutionStandards Met: IEC 6100-4-5, ANSI/IEEE C62.41 Cat. B, UL 1449 (8/98) , IEC 61000-4-4Test duration-2: ±20% Tolerance$0.00In Stock -
Thermo Keytek
SKU: sku-289
Rent Thermo Fisher Keytek ECAT Surge & Burst/EFT Simulator System
Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & VariationsStandards Met: IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11, IEEE C62.41, UL 864Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITMax EUT AC Voltage (w/ Built in CDN): 220 VoltsMax EUT AC Current (w/ Built in CDN): 15 AmpsMax EUT DC Voltage (w/ Built in CDN): 220 VoltsMax EUT DC Current (w/ Built in CDN): 15 AmpsPeak inrush current capability: 500 AmpsEFT/Burst Pulse Output Capability: 4.4 kVCombination/Wave Surge Output Capability: 6.6 kVExternal Coupling: Data Lines (EFT & Surge), 3PH EUTVideos: 10kV Surge Example$1,250.00In Stock -
EM Test
SKU: sku-241
EM Test UCS500N7 Multifunctional Transient Immunity Simulator
Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & VariationsStandards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-29Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITMax EUT AC Voltage (w/ Built in CDN): 264 VoltsMax EUT AC Current (w/ Built in CDN): 16 AmpsMax EUT DC Voltage (w/ Built in CDN): 220 VoltsMax EUT DC Current (w/ Built in CDN): 10 AmpsPeak inrush current capability: 500 A (at 230 V)EFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kACombination/Wave Surge Output Capability: ±200 V to 4.4 kV (in 1 V steps)External Coupling: Data Lines (EFT & Surge), 3PH EUTCoupling: L, N, PE; all combinationsCoupling-2: L, N, PE; line to line and line(s) to groundDips, Interrupts & Variations: As per IEC/EN 61000-4-11, IEC/EN 61000-4-29 and IEC/EN 61000-6-1, -6-2Impedance: 12 ohm and 30 ohmPhase synchronization: 0° - 360°, resolution 1° (16 - 500Hz)Phase synchronization-2: 0° - 360°, resolution 1° (16 - 500Hz)Phase synchronization-3: 0° - 360°, resolution 1°Polarity: positive / negativePolarity-2: Positive, negativePolarity-3: Positive, negative, alternatingPulse current (short circuit): Wave ShapePulse repetition: Automatic, manual, externalPulse voltage (open circuit): 250 V - 6,000 V ± 10%Repetition time: 10ms - 9,999sTest duration: 0:01min - 99:59minTest duration-2: max. 1 Hz (1 s - 999 s)Weight: 25 kg's (55 Lbs)Application/Test Type: CE Marking - Cover transient and power fail requirements according to international standards for immunity testsBurst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Burst frequency: 0.1 kHz - 1,000 kHzBurst time: 0.10ms - 999msCombination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Counter: 1 - 30,000 or endless, selectableCoupling-3: As per IEC 61000-4-5: Line to line with 2 ohm, Line(s) to ground with 12 ohm; As per ANSI/IEEE C62.41: Line to line with 2ohm, Line(s) to ground with 2ohmDimensions: 19", 3HUDips, Interrupts & Variations-2: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29Energy Storage Capacitor: 20 uFEvent time: 20us - 9,999sEvent Trigger: Automatic, manual, externalFront Time: As per ITU and ETSI recommendations: 10 us ± 30%; As per FCC part 68, Pulse B: 9 us ± 30%; As per IEC 61000-4-5: 5 us ± 30%Impedance-2: 2 Ohm / 12 OhmOutput Current: 6 A - 175 A (short circuit) at 25 Ohm OutputOutputs: For 2-wire T1/T2 with 25 ohm each & For 4-wire T1/T2/T3/T4 with 25 ohm eachPeak inrush current capability: 500 AmpsPhase synchronization-4: 0° - 360°, resolution 1°Polarity-4: positive / negative / alternatingPulse amplitude: 200V - 5,500V ± 10%; 100V - 2,750V ± 10% into 50ohmPulse current (short circuit)-2: Max. 3,500 A ± 10%Pulse Duration: As per ITU and ETSI recommendations: 700 us ± 20%; As per FCC part 68, Pulse B: 720 us ± 20%; As per IEC 61000-4-5: 320 us ± 20%Pulse repetition-2: max. 0.5Hz (2s - 999s)Pulse voltage (open circuit)-2: 250 V - 7,000 V ± 10%Repetition Rate: Max. 0.33 Hz (3 s - 999 s)Repetition time-2: 10ms - 9,999msRingwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41Standards Met: ANSI/IEEE C62.41; IEC 61000-4-11; IEC 61000-4-12; IEC 61000-4-29; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-8; IEC 61000-4-9; EN 61000-6-1; EN 61000-6-2; ITU-T K.XX; UL 1741Switching times: Under 5us into a 100ohm resistive loadTelecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendationsTest duration-3: 1 - 30,000 or endless, selectableTest Voltage: 250 V - 7,000 V ± 10%Uvar with optional variac: N/AUvar with step transformer: 300V AC$0.00 -
EM Test
SKU: sku-240
EM Test UCS 500N5 Multifunctional Generator for EFT/Burst, Surge & Power Fail up to 5.5kV
Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & VariationsStandards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-29Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITMax EUT AC Voltage (w/ Built in CDN): 264 VoltsMax EUT AC Current (w/ Built in CDN): 16 AmpsMax EUT DC Voltage (w/ Built in CDN): 220 VoltsMax EUT DC Current (w/ Built in CDN): 10 AmpsPeak inrush current capability: 500 A (at 230 V)EFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kACombination/Wave Surge Output Capability: ±200 V to 4.4 kV (in 1 V steps)External Coupling: Data Lines (EFT & Surge), 3PH EUTCoupling: L, N, PE; all combinationsDips, Interrupts & Variations: As per IEC/EN 61000-4-11, IEC/EN 61000-4-29 and IEC/EN 61000-6-1, -6-2Phase synchronization: 0° - 360°, resolution 1° (16 - 500Hz)Phase synchronization-2: 0° - 360°, resolution 1° (16 - 500Hz)Polarity: positive / negativeRepetition time: 10ms - 9,999sTest duration: 0:01min - 99:59minWeight: 25 kg's (55 Lbs)Application/Test Type: CE Marking - Cover transient and power fail requirements according to international standards for immunity testsBurst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Burst frequency: 0.1 kHz - 1,000 kHzBurst time: 0.10ms - 999msCombination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling-2: Line to line; Line(s) to groundDimensions: 19", 3HUDips, Interrupts & Variations-2: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29Event time: 20us - 9,999sImpedance: 2 OhmPeak inrush current capability: 500 AmpsPhase synchronization-3: 0° - 360°, resolution 1°Polarity-2: positive / negative / alternatingPulse amplitude: 200V - 5,500V ± 10%; 100V - 2,750V ± 10% into 50ohmPulse current (short circuit): Max. 2,500A ± 10%Pulse repetition: max. 1Hz (1s - 999s)Pulse voltage (open circuit): 160V - 5,000V ± 10%Repetition time-2: 10ms - 9,999msStandards Met: FCC 97-270 (part 68); IEC 60255-22-5; IEC 61000-4-11; IEC 61000-4-29; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-8; IEC 61000-4-9; IEC 61326; IEC 61850-3Switching times: Under 5us into a 100ohm resistive loadTest duration-2: 1 - 30,000 or endless, selectableUvar with optional variac: N/AUvar with step transformer: 300V AC + DC$0.00 -
$0.00
-
The EMC Shop
SKU: sku-1857
Surge4-5 Combination Wave Surge Generator per EN/IEC 61000-4-5
Standards Met: IEC/EN 61000-4-5, IEC/ISO 60601-1-2Applications: EMC Surge, CE MarkingMax EUT AC Voltage (W/ Built In CDN): 230 VoltsMax EUT AC Current (W/ Built In CDN): 16 AmpsMax EUT DC Voltage (W/ Built In CDN): 270 VoltsMax EUT DC Current (W/ Built In CDN): 16 AmpsCombination/Wave Surge Output Capability: 4.4 kVExternal Coupling: Data Lines (Surge), 3PH EUTCalibration: ISO 17025 Accredited (Upon Request)Videos: Manual$0.00Usually ships in 24 hours.