RF Conducted Immunity Test Generators

The EMC Shop stocks a variety of RF conducted immunity test generators used in conducted immunity testing and compliance. These systems have integrated signal generators, RF amplifiers and power sensors, keeping hardware minimal for tests such as IEC 61000-4-6ISO 11452-4 and MIL-STD-461 CS114.

RF Conducted Immunity Test Setup vs Test Generator...

The EMC Shop stocks a variety of RF conducted immunity test generators used in conducted immunity testing and compliance. These systems have integrated signal generators, RF amplifiers and power sensors, keeping hardware minimal for tests such as IEC 61000-4-6ISO 11452-4 and MIL-STD-461 CS114.

RF Conducted Immunity Test Setup vs Test Generator

Typical RF Conducted Immunity Test Setup

RF Conducted Immunity Test Equipment Typical Setup

RF Conducted Immunity Test Setup Using All-in-one Generator

RF Conducted Immunity Test Generator

More

RF Conducted Immunity Test Generators There are 21 products.

per page
Showing 1 - 12 of 21 items
    • 150 kHz - 230 MHz Frequency Range
    • Turnkey software for IEC 61000-4-6
    • 75 Watt Integrated Amplifier
    • Achieve 30 Vrms with a BCI probe
    • Computer Based System (USB controlled)
    • Self Calibration with CDN, EM Clamp or Injection Probe
    • RF generator, amplifier and RF Voltmeter usable as independent instruments
    • Connections: EUT "Fail", EUT monitoring by external multimeter
    Request Quote/More Info
    • Integrated signal generator 4 kHz to 1 GHz
    • 3 power meter inputs 4 kHz to 1 GHz
    • Integrated class A power amplifier module:
      Multiple EUT monitoring options
      • 45 W, 9 kHz to 1 GHz
    • 5,7“ TFT color display
    • Internal, menu-based control software
    • Basic remote control software and report generator included
    • Optically decoupled remote control
    • Whisper mode
    Request Quote/More Info
    • 10 kHz–400 MHz Frequency Range
    • Bulk Current Injection (BCI) RF Conducted Immunity System
    • 100 Watts nominal

    Complete testing solutions to the following standards:

    Request Quote/More Info
    • Meets:
      • ISO 11452-4
      • FMC1278
      • GMW3097
      • Many more...
    • Easy Setup and Teting
    • Lightweight and Portable
    • Achieves:
      • 400mA in Substituion Method
      • 200mA in Closed Loop Method
    Request Quote/More Info
    • Conductive immunity test system with optional CDN, EM Clamp and or Current Injection Clamp
    • Easily sweep from 150 kHz to 230 MHz up to 10 Vrms
    • Meet IEC 61000-4-6 with easy plug and play system
    • Easy to setup and use with dedicated laptop/software
    Request Quote/More Info
    • In stock, calibrated and ready to ship
    • Turnkey CDN, BCI and EM Clamp solutions for IEC 61000-4-6
    • 35 Watt, 150kHz to 230 MHz Integrated class A power amplifier (See Teseq NSG4070-45 for expanded capabilities)
      Multiple EUT monitoring options
    • 5.7“ TFT color display
    • Internal, menu-based control software
    • Basic remote control software and report generator included
    • Whisper mode
    Request Quote/More Info
    • 150 kHz - 230 MHz Frequency Range
    • Turnkey software for IEC 61000-4-6
    • 25 Watt Integrated Amplifier
    • Computer Based System (USB controlled)
    • Self Calibration with CDN, EM Clamp or Injection Probe
    • RF generator, amplifier and RF Voltmeter usable as independent instruments
    • Connections: EUT "Fail", EUT monitoring by external multimeter
    Request Quote/More Info
    • Test procedure acc. IEC 61000-4-6 Ed. 4
    • Built-in amplifier saturation and linearity check
    • Built-in power amplifier 25 to 80 watts, 10 kHz to 400 MHz
    • Built-in power meter, 9 kHz to 1 GHz
    • Built-in dual directional coupler
    • Automatic calibration via built-in power meter
    • Connection for external amplifiers up to 1 GHz
    • USB-Interface
    • Software for Windows 7, Windows 8
    Request Quote/More Info
    • 10 kHz - 250 MHz Frequency Range
    • 75 Watt Integrated Amplifier
    • Achieve 40 Vrms with a BCI probe
    • Computer Based System (USB controlled)
    • Self Calibration with Injection Probe
    • RF generator, amplifier and RF Voltmeter usable as independent instruments
    • Connections: EUT "Fail", EUT monitoring by external multimeter
    Request Quote/More Info
    • Signal generator and integrated power amplifier 15 Hz to 150 kHz
    • Meets IEC / EN 61000-4-16 in combination with NSG 4060-1
    • Meets IEC / EN 61000-4-19 in combination with CDND M316-2 for voltage and CT 419-5 for current testing
    • Prepared test configurations for IEC / EN 61000-4-16 and IEC / EN 61000-4-19
    • 5.7” color display 
    • Multiple EUT monitoring options
    Request Quote/More Info
    • Model CI00250A (75 Watt amplifier, 10 kHz – 250 MHz)
    • Model CI00400A (100 Watt amplifier, 10 kHz – 400 MHz)
    • Model CI00401A (150 Watt amplifier, 100 kHz – 400 MHz) 
    • EN/IEC 61000-4-6 Testing Solution
    Request Quote/More Info
    • Conductive immunity test system with optional CDN, EM Clamp and or Current Injection Clamp
    • Meet IEC 61000-4-6 or MIL-STD-461 CS114
    • Easy to setup and use of software
    Request Quote/More Info
Showing 1 - 12 of 21 items