Quick Links

Information

EMC Generators / Measurement Systems

                                                                                                                                    



                                            

EMC Generators / Measurement Systems There are 15 products.

per page
Showing 1 - 12 of 15 items
    • EN 55103-1, 2
    • EN/IEC61000-4-8
    • Automotive
    • MIL-STD 
    • Generation and measurement of magnetic fields from DC up to 250 kHz
    • Field strengths up to 1000 A/m 
    • Additional Options (separate)
      • Sensor coils
      • Helmholtz coils
      • Test adapter
    Request Quote/More Info
    • 0,1 / 2000 µs Wave form
    • 4 kV – 10 kV Test voltage
    Request Quote/More Info
    • For EMC test according to the standard IEC /EN 61000-4-16
    • Output module with 5A / 250 W
    • DC, sine, triangle and square waveforms external
    • Input adds to internal signal source Windows
    • Application software via USB port
    Request Quote/More Info
    • Generation of magnetic fields by 3-channel generator/amplifier combination for calibration purpose
    • Complies to IEEE644
    • Loop sensor for field verification is included
    • Application Software WIN7 compatible
    • Connection to computer via USB-port
    Request Quote/More Info
    • Operation via capacitive color touch display
    • Burst - frequency up to 125 kHz, pulse amplitude up to 5.0 kV
    • Modification of all parameters during the test possible
    • Single impulse to permanent burst, various special functions
    • Max. 5000 pulses / sec. and 500 pulses / packet
    • Time accurate triggering
    Request Quote/More Info
    • 150 kHz - 230 MHz Frequency Range
    • Turnkey software for IEC 61000-4-6
    • 25 Watt Integrated Amplifier
    • Computer Based System (USB controlled)
    • Self Calibration with CDN, EM Clamp or Injection Probe
    • RF generator, amplifier and RF Voltmeter usable as independent instruments
    • Connections: EUT "Fail", EUT monitoring by external multimeter
    Reduced price!
    Request Quote/More Info
    • 100 kHz - 250 MHz Frequency Range
    • 25 W Power
    • Computer-based system (controlled by USB)
    • Self-calibration of the test system (generator and CDN)
    • RF-generator, amplifier and RF-voltmeter may as well be used as stand-alone devices
    • Connections: EUT “Fail”, EUT monitoring by external multimeter, e.g. DUT signal
    • Calibration of coupling / decoupling devices and EM clamp is performed automatically
    • Extensive additions like attenuators, calibration kits, etc. deliverable
    • Directional Coupler ( DC )
    Request Quote/More Info
    • 100 kHz - 300 MHz Frequency Range
    • 75 W Power
    • Computer-based system (controlled by USB)
    • Self-calibration of the test system (generator and CDN)
    • RF-generator, amplifier and RF-voltmeter may as well be used as stand-alone devices
    • Connections: EUT “Fail”, EUT monitoring by external multimeter, e.g. DUT signal
    • Calibration of coupling / decoupling devices and EM clamp is performed automatically
    • Extensive additions like attenuators, calibration kits, etc. deliverable
    • Directional Coupler ( DC )
    Request Quote/More Info
    • 100 kHz - 300 MHz Frequency Range
    • 75 W Power
    • Computer-based system (controlled by USB)
    • Self-calibration of the test system (generator and CDN)
    • RF-generator, amplifier and RF-voltmeter may as well be used as stand-alone devices
    • Connections: EUT “Fail”, EUT monitoring by external multimeter, e.g. DUT signal
    • Calibration of coupling / decoupling devices and EM clamp is performed automatically
    • Extensive additions like attenuators, calibration kits, etc. deliverable
    • Directional Coupler ( DC )
    Request Quote/More Info
    • 10 kHz - 250 MHz Frequency Range
    • 75 W Power
    • Computer-based system (controlled by USB)
    • Self-calibration of the test system (generator and CDN)
    • RF-generator, amplifier and RF-voltmeter may as well be used as stand-alone devices
    • Connections: EUT “Fail”, EUT monitoring by external multimeter, e.g. DUT signal
    • Calibration of coupling / decoupling devices and EM clamp is performed automatically
    • Extensive additions like attenuators, calibration kits, etc. deliverable
    • Directional Coupler ( DC )
    Request Quote/More Info
    • 10 kHz - 250 MHz Frequency Range
    • 75 W Power
    • Computer-based system (controlled by USB)
    • Self-calibration of the test system (generator and CDN)
    • RF-generator, amplifier and RF-voltmeter may as well be used as stand-alone devices
    • Connections: EUT “Fail”, EUT monitoring by external multimeter, e.g. DUT signal
    • Calibration of coupling / decoupling devices and EM clamp is performed automatically
    • Extensive additions like attenuators, calibration kits, etc. deliverable
    • Directional Coupler ( DC )
    Request Quote/More Info
    • 280 V AC max. 
    • 360 V DC max. 
    • AC-Test: IEC / EN 61000-4-11
    • DC-Test: IEC / EN 61000-4-29
    • Inrush Current Measurement at any Phase Position 0° - 360 ° 
    • Automatic AC + DC Ramp Function
    Request Quote/More Info
Showing 1 - 12 of 15 items