Conducted Disturbance Test Generators

Rent, buy or lease Schloder Conducted Disturbance Test Generators. The EMC Shop specializes RF conducted immunity testing to IEC 61000-4-6. ISO 11452, MIL CS114 and more. These systems have integrated signal generators, RF amplifiers and power sensors, keeping hardware minimal for tests such as IEC 61000-4-6ISO 11452-4 and MIL-STD-461 CS114.

T...

Rent, buy or lease Schloder Conducted Disturbance Test Generators. The EMC Shop specializes RF conducted immunity testing to IEC 61000-4-6. ISO 11452, MIL CS114 and more. These systems have integrated signal generators, RF amplifiers and power sensors, keeping hardware minimal for tests such as IEC 61000-4-6ISO 11452-4 and MIL-STD-461 CS114.

Test Setup - Conducted Disturbance Test Generators

Test Setup - Conducted Disturbance Test Generators

Plug and Play Software - Conducted Disturbance Test Generators

More

Conducted Disturbance Test Generators There are 7 products.

Showing 1 - 7 of 7 items
    • For EMC test according to the standard IEC /EN 61000-4-16
    • Output module with 5A / 250 W
    • DC, sine, triangle and square waveforms external
    • Input adds to internal signal source Windows
    • Application software via USB port
    Request Quote/More Info
    • 150 kHz - 230 MHz Frequency Range
    • Turnkey software for IEC 61000-4-6
    • 25 Watt Integrated Amplifier
    • Computer Based System (USB controlled)
    • Self Calibration with CDN, EM Clamp or Injection Probe
    • RF generator, amplifier and RF Voltmeter usable as independent instruments
    • Connections: EUT "Fail", EUT monitoring by external multimeter
    Reduced price!
    Request Quote/More Info
    • 100 kHz - 250 MHz Frequency Range
    • 25 W Power
    • Computer-based system (controlled by USB)
    • Self-calibration of the test system (generator and CDN)
    • RF-generator, amplifier and RF-voltmeter may as well be used as stand-alone devices
    • Connections: EUT “Fail”, EUT monitoring by external multimeter, e.g. DUT signal
    • Calibration of coupling / decoupling devices and EM clamp is performed automatically
    • Extensive additions like attenuators, calibration kits, etc. deliverable
    • Directional Coupler ( DC )
    Request Quote/More Info
    • 100 kHz - 300 MHz Frequency Range
    • 75 W Power
    • Computer-based system (controlled by USB)
    • Self-calibration of the test system (generator and CDN)
    • RF-generator, amplifier and RF-voltmeter may as well be used as stand-alone devices
    • Connections: EUT “Fail”, EUT monitoring by external multimeter, e.g. DUT signal
    • Calibration of coupling / decoupling devices and EM clamp is performed automatically
    • Extensive additions like attenuators, calibration kits, etc. deliverable
    • Directional Coupler ( DC )
    Request Quote/More Info
    • 100 kHz - 300 MHz Frequency Range
    • 75 W Power
    • Computer-based system (controlled by USB)
    • Self-calibration of the test system (generator and CDN)
    • RF-generator, amplifier and RF-voltmeter may as well be used as stand-alone devices
    • Connections: EUT “Fail”, EUT monitoring by external multimeter, e.g. DUT signal
    • Calibration of coupling / decoupling devices and EM clamp is performed automatically
    • Extensive additions like attenuators, calibration kits, etc. deliverable
    • Directional Coupler ( DC )
    Request Quote/More Info
    • 10 kHz - 250 MHz Frequency Range
    • 75 W Power
    • Computer-based system (controlled by USB)
    • Self-calibration of the test system (generator and CDN)
    • RF-generator, amplifier and RF-voltmeter may as well be used as stand-alone devices
    • Connections: EUT “Fail”, EUT monitoring by external multimeter, e.g. DUT signal
    • Calibration of coupling / decoupling devices and EM clamp is performed automatically
    • Extensive additions like attenuators, calibration kits, etc. deliverable
    • Directional Coupler ( DC )
    Request Quote/More Info
    • 10 kHz - 250 MHz Frequency Range
    • 75 Watt Power Amplifier
    • Meet MIL-STD 461 CS114 BCI requirements
    • Computer-based system (controlled by USB)
    • Self-calibration of the test system (generator and CDN)
    • RF-generator, amplifier and RF-voltmeter may as well be used as stand-alone devices
    • Connections: EUT “Fail”, EUT monitoring by external multimeter, e.g. DUT signal
    • Calibration of coupling / decoupling devices and EM clamp is performed automatically
    • Extensive additions like attenuators, calibration kits, etc. deliverable
    • Directional Coupler ( DC )
    Request Quote/More Info
Showing 1 - 7 of 7 items