Rent Rigol DSA710 100kHz to 1GHz Spectrum Analyzer

Rigol

Write a Review
SKU:
sku-1123
$0.00
$0.00

Description

The Rigol DSA710 is a compact and light weight Spectrum Analyzer with premium performance for portable applications. The use of digital IF (intermediate frequency) technology guarantees reliability and performance to meet the most demanding RF applications. The very large display (20.3 cm / 8") of the Rigol DSA710 Spectrum Analyzer provides a resolution of 800x480 pixels allowing a very good overview of all its comfortable functions like Auto Tune, Auto Range, Auto Scale and Auto Couple. These functions enable the analyzer to acquire signals and match parameters automatically, compared to the manual process necessary with a traditional analyzer. The Rigol Spectrum Analyzers have a sophisticated and easy to use user interface offering multiple functions for all tasks. The menu navigation is very intuitive and all functions and parameters are easy to locate thanks to the graphical interface.

Benefits of Rigol's all Digital IF Design

  • High precision amplitude readings: this technology almost eliminates the errors generated by filter switching, reference level uncertainty, scale distortion, as well as errors produced in the process of switching between logarithmic and linear display of amplitude when using a traditional analog IF design.
  • Higher reliability: compared with traditional analog designs, the digital IF greatly reduces the complexity of the hardware, the system instability caused by channel aging, and the temperature sensitivity that can contribute to parts failure.
  • The ability to measure smaller signals: on the basis of this technology, the IF filter enables smaller bandwidth settings, which greatly reduce the displayed average noise level.
  • The ability to distinguish between small signals by frequency: using the IF filter with the smallest bandwidth setting, it is possible to make out signals with a frequency difference of only 100 Hz.
  • High measurement speed: the use of digital IF technology improves the bandwidth precision and selectivity of the filter, minimizing the scanning time and improving the speed of the measurement.


Key Functions

Rigol DSA710 Key Functions

SPECIFICATIONS
Specifications are valid under the following conditions: the instrument is within the calibration period, is stored for at least two hours at 0°C
to 50 °C temperature, and is warmed up for 40 minutes. Unless otherwise noted, the specifications in this manual include the measurement
uncertainty.
Typical (typ.): characteristic performance, which 80 percent of the measurement results will meet at room temperature (approximately 25°C ).
This data is not warranted and does not include the measurement uncertainty.
Nominal (nom.): the expected mean or average performance or a designed attribute (such as the 50O connector). This data is not warranted
and is measured at room temperature (approximately 25°C ).
Measured (meas.): an attribute measured during the design phase which can be compared to the expected performance, such as the
amplitude drift variation with time. This data is not warranted and is measured at room temperature (approximately 25°C ).
NOTE: All charts in this manual are the measurement results of multiple instruments at room temperature unless otherwise noted. The
specifications (except the TG specifications) listed in this manual are those when the tracking generator is off.
DSA705 DSA710
Frequency
Frequency range 100 kHz to 500 MHz 100 kHz to 1 GHz
Frequency resolution 1 Hz
Internal Reference Frequency
Reference frequency 10 MHz
Accuracy ±[ (time since last calibration × aging rate) + temperature stability + calibration accuracy]
Initial calibration accuracy <1 ppm
Temperature stability 0? to 50? , reference to 25?
<2 ppm
Aging rate <2 ppm/year
Frequency Readout Accuracy
Marker resolution span/ (number of sweep points - 1)
Marker uncertainty ±(frequency indication × reference frequency accuracy + 1% × span + 10% × resolution bandwidth +
marker resolution)
Frequency Counter
Resolution 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz
Uncertainty ±(frequency indication × reference frequency accuracy + counter resolution)
Frequency Span
Range 0 Hz, 100 Hz to maximum frequency of instrument
Uncertainty ±span/ (number of sweep points - 1)
SSB Phase Noise
20? to 30? , fc = 500 MHz 20? to 30? , fc = 1 GHz
Carrier offset <-80 dBc/Hz <-100 dBc/Hz (typ.)
Residual FM
20? to 30? , RBW = VBW = 1 kHz
Residual FM <50 Hz (nom.)
Bandwidths
Set "Auto SWT" to "Accy"
Resolution bandwidth (-3 dB) 100 Hz to 1 MHz, in 1-3-10 sequence
RBW uncertainty <5% (nom.)
Resolution filter shape factor (60 dB : 3 dB) <5 (nom.)
Video bandwidth (-3 dB) 1 Hz to 3 MHz, in 1-3-10 sequence
Resolution bandwidth (-6 dB) (EMI-DSA800 option) 200 Hz, 9 kHz, 120 kHz
Amplitude
Measurement Range fc ≥ 10 MHz
DANL to +20 dBm
Maximum Input Level
DC voltage 50 V
CW RF power attenuation = 30 dB
+20 dBm (100 mW)
Max. damage level[1] +30 dBm (1 W)
NOTE: [1] When fc ≥ 10 MHz, input level > +25 dBm and PA is Off, the protection switch will be on.
Displayed Average Noise Level (DANL)
Frequency attenuation = 0 dB, RBW = VBW = 100 Hz, sample detector, trace average ≥ 50, 20? to 30? , input impendence = 50 Ω
PA off 100 kHz to 1 MHz <-90 dBm, <-110 dBm (typ.)
1 MHz to 500 MHz <-100 dBm, <-110 dBm (typ.)
500 MHz to 1 GHz <-100 dBm, <-110 dBm (typ.)
PA on 100 kHz to 1 MHz <-110 dBm, <-130 dBm (typ.)
1 MHz to 500 MHz <-120 dBm, <-130 dBm (typ.)
500 MHz to 1 GHz <-120 dBm, <-130 dBm (typ.)
Level Display
Logarithmic level axis 1 dB to 200 dB
Linear level axis 0 to reference level
Number of display points 601
Number of traces 3 + math trace
Trace detectors normal, positive-peak, negative-peak, sample, RMS, voltage average
quasi-peak (with EMI-DSA800 option)
Trace functions clear write, max hold, min hold, average, view, blank
Units of level axis dBm, dBmV, dBμV, nV, μV, mV, V, nW, μW, mW, W
Frequency Response
Frequency response fc ≥ 100 kHz, attenuation = 10 dB, relative to 50 MHz, 20? to 30?
PA off 100 kHz to 500 MHz <0.7 dB
500 MHz to 1 GHz <0.7 dB
PA on 100 kHz to 500 MHz <1.0 dB
500 MHz to 1 GHz <1.0 dB
Input Attenuation Switching Uncertainty
Setting range 0 dB to 30 dB, in 1 dB step
Switching uncertainty fc = 50 MHz, relative to 10 dB, 20? to 30?
<0.5 dB
Absolute Amplitude Uncertainty
Uncertainty fc = 50 MHz, peak detector, preamplifier off, attenuation = 10 dB, input signal level = -10dBm,
20? to 30?
<0.4 dB
RBW Switching Uncertainty
Uncertainty relative to 1 kHz RBW
<0.1 dB
Reference Level
Range -100 dBm to +20 dBm, in 1 dB step
Resolution log scale 0.01 dB
linear scale 4 digits
Preamplifier
Gain 100 kHz to 500 MHz - 20 dB (nom.)
500 MHz to 1 GHz - 20 dB (nom.)
Level Measurement Uncertaint 95% confidence level, S/N > 20 dB, RBW = VBW = 1 kHz, preamplifier of f, attenuation = 10 dB, -50 dBm < input level ≤ 0 dBm, fc > 10 MHz, 20? to 30?
Level measurement uncertainty <1.5 dB (nom.)
RF Input VSWR attenuation ≥ 10 dB
VSWR 300 kHz to 500 MHz <1.5 (nom.)
500 MHz to 1 GHz <1.5 (nom.)
Distortion
Second Harmonic Intercept
Second harmonic intercept (SHI) fc ≥ 50 MHz, input signal level = -20 dBm, attenuation = 10 dB
+40 dBm
Third-order Intercept
Third-order intercept (TOI) fc ≥ 50 MHz, two -20 dBm tones at input mixer spaced by 200 kHz, attenuation = 10 dB
+10 dBm
1dB Gain Compression
1dB compression of input mixer (P1dB) fc ≥ 50 MHz, attenuation = 0 dB
>0 dBm
Spurious Response
Spurious response, inherent input terminated 50 Ω, attenuation = 0 dB, 20? to 30?
<-88dBm (typ.)
Intermediate frequency <-60 dBc
System related sidebands referenced to local oscillators, referenced to A/D conversion, referenced to
subharmonic of first LO, referenced to harmonic of first LO
<-60 dBc
Input related spurious mixer level = -30 dBm
<-60 dBc
Sweep
Sweep time span ≥ 100 Hz 10 ms to 500 s span ≥ 100 Hz 10 ms to 1000 s
zero span 20 μs to 500 s zero span 20 μs to 1000 s
Sweep time uncertainty span ≥ 100 Hz 5% (nom.)
zero span (sweep time setting value > 1 ms) 5% (nom.)
Sweep mode continuous, single
Trigger
Trigger source free run, video, external
External trigger level 5 V TTL level
SSC-DSA (Option)
Signal Seamless Capture (SSC)
Measurement bandwidth 202 kHz
Measurement speed 650 spectrums/s
Input /Output
Front Panel Connectoc
RF input impedance 50 Ω (nom.)
connector N female
Internal/ External Reference
Internal reference frequency 10 MHz
output level +3 dBm to +10 dBm, +8 dBm (typ.)
impedance 50 Ω (nom.)
connector BNC female
External reference frequency 10 MHz ± 5 ppm
input level 0 dBm to +10 dBm
impedance 50 Ω (nom.)
connector BNC female
External trigger input impedance 1 kΩ (nom.)
connector BNC female
Communication Interface
USB host connector A plug
protocol version2.0
USB device connector B plug
protocol version2.0
LAN LXI core 2011 device 10/100Base, RJ-45
IEC/IEEE (GPIB) bus (USB-GPIB option) IEEE488.2
General Specifications
Display
Type TFT LCD
Resolution 800 x 480 pixels
Size 8 inch
Colors 64k
Printer Supported
Protocol PictBridge
Mass memory flash disk (internal), USB storage device (not supplied)
Power Supply
Input voltage range, AC 100 V to 240 V (nom.)
AC supply frequency 45 Hz to 440 Hz
Power consumption 35 W (typ.), max. 50 W with all options
Environmental
Temperature operating temperature range 0° to 50°
storage temperature range -20° to 70°
Humidity 0° to 30° ≤ 95% rel. humidity
30° to 40° ≤ 75% rel. humidity
Electromagnetic Compatibility and Safety
EMC in line with EN61326-1:2006
IEC 61000-4-2:2001 ±4.0 kV (contact discharge), ±4.0 kV (air discharge)
IEC 61000-4-3:2002 3 V/m (80 MHz to 1 GHz), 3 V/m (1.4 GHz to 2 GHz), 1 V/m (2.0 GHz to 2.7
GHz)
IEC 61000-4-4:2004 1 kV power lines
IEC 61000-4-5:2001 0.5 kV (phase to neutral), 0.5 kV (phase to PE), 1 kV (neutral to PE)
IEC 61000-4-6:2003 3 V, 0.15 to 80 MHz
IEC 61000-4-11:2004 voltage dip: 0% UT during half cycle, 0% UT during 1 cycle, 70% UT during
25 cycles
short interruption: 0% UT during 250 cycles
Electrical safety in line with
UL 61010-1:2012, CAN/CSA-C22.2 No. 61010-1-12, EN 61010-1:2010
Dimensions
(W x H x D) 361.6 mm × 178.8 mm × 128 mm
(14.2 in × 7.0 in × 5.0 in)
WeightStandard 4.25 kg (9.4 lb)
Recommended calibration interval 1 year

Extra Information

Brand:
Rigol