Description
- Frequency Range: 10kHz to 30 MHz
- Impedance Characteristics: Z = 50Ω || (50µH + 5Ω), Error <20% under terms of VDE 876T1
- Max. Current: 16A Line
- Voltage/Frequency: 230V/50…60Hz, CAT II
- Artificial Hand: 220pF + 511Ω PE (selectable): 50µH || 50Ω
Transient Limiter
- Frequency Range: 150kHz to 30MHz
- Transmission Loss: 10dB (+1.5/-0.5dB)
- Connectors Measurement
- Output: 50Ω BNC
- Power Supply Socket for DUT: Schuko plug socket for: HM6050-2D (DE Version) HM6050-2K (UK Version) HM6050-2S (US Version)
- Artificial Hand: 4mm banana socket Line Cord: Fixed
- Operating Temperature: 10°C to 40°C
- Power Supply: HM6050-2D (DE Version) 230V ±10%, 50…60Hz HM6050-2K (UK Version) 230V ±10%, 50…60Hz HM6050-2S (US Version) 115V ±10%, 50…60Hz
- Safety Class: Safety class I (IEC1010-1/VDE 0411)
- Dimensions (W x H x D): 285 x 125 x 380mm
- Weight: Approx. 6kg
Videos
Custom Field
Weight 6 kg
Application/Test Type Power Line Conducted Emissions Tests
Current Rating 16 Amperes
Dimensions 285 x 125 x 380mm
Frequency Range 10kHz to 30 MHz
Inductors 50 µH
Insertion loss 10 dB
Isolation more than 40 dB
Mains & EUT Connections 5.5/2.5 mm Power Jack
RF Connector RF Measurement Port 50Ω - BNC
Standards Met CISPR 16-1-2
Voltage Rating 230V/50…60Hz, CAT II (line to ground) Max DC Voltage: 705V