Description
The EMCO/ETS-Lindgren 3142 s suitable for Ideally suitable for IEC 61000-4-3 Immunity Testing and CISPR 11, ANSI C63.4, FCC-18 plus EN 55022 for Emissions Testing. The antennas mounting bracket will fit on to a number of adaptors.
Videos
Custom Field
Impedance 50 Ω
Weight approx. 4 kg
Antenna Factor (1 Meter) 30 MHz: 12 dB/m;
60 MHz: 10 dB/m;
300 MHz: 14 dB/m;
500 MHz: 18 dB/m;
1000 MHz: 25 dB/m;
2000 MHz: 30 dB/m
Antennas Bilogical Antennas
Application/Test Type Precompliance RF Immunity & Emissions Testing
Connector N type female
Dimensions (L x W x H) 29.5" x 53.1" x 35.4"
Frequency Range 26 MHz to 2 GHz
Impedance-2 50 Ω
Maximum Continuous Power 300 Watts
Standards Met CISPR 11
CISPR 13,
CISPR 14-1,
CISPR 16-1-4,
CISPR 16-2-3,
CISPR 22,
CISPR 32,
IEC 61000-4-3
ANSI C63.4
FCC-18
EN 55022
VSWR 2:1 average