Description
Teseq DCP 0100 Description:
BCI and radiated immunity systems require the accurate monitoring of forward and reflected power
levels into clamps, antennas or other transducers. This high power dual directional coupler has been
specifically designed for EMC immunity applications.
Standards Met:
- IEC/EN 61000-4-3
- IEC/EN 61000-4-6
- IEC/EN 61000-4-20
- CISPR 24
- EN 61000-6-1
- EN 61000-6-2
- IEC 60533
- IEC 60601-1-2
- IEC 61326
- MIL STD 461
- RTCA/DO 160
- ISO 11452-2
- ISO 11452-3
- ISO 11452-4
- ISO 11452-5
- SAE J1113-4
- SAE J1113-24
Parameter | Value |
---|---|
Frequency range | 10 kHz to 1 GHz |
Impedance | 50 Ω |
Power, nominal | 100 W |
Insertion loss (gate 1 - gate 2) | ≤ 0.8 dB (≤ 0.5 dB up to 400 MHz/ ≤ 0.8 dB up to 1 GHz) |
VSWR | < 1:1.4 (gate 1 - gate 2) |
Videos
Custom Field
Weight approx. 700 g
Connectors N type female (gate 1, 3 and 4), N type male (gate 2)
Coupling EMC Applications
Coupling factor 40 dB ± 1.5 dB (gate 1 - gate 3 and gate 2 - gate 4)
Cross talk attenuation 40 dB (gate 3 - gate 4)
Dimensions 190 mm x 105 mm x 45 mm
Directivity 20 dB
Frequency range 10 kHz to 1 GHz
General Data Technical Details
Impedance 50 Ω
Insertion loss 0.8 dB ( 0.5 dB up to 400 MHz/ 0.8 dB up to 1 GHz)
Power, nominal 100 W
VSWR 1:1.4 (gate 1 - gate 2)