Quick view Details sku: sku-2132 EMIC-35 Current Injection Clamp for RF Conducted Immunity Testing View Details
Quick view Details sku: sku-1009 Schloder CDN CAN-BUS 150 kHz – 230 MHz Coupling / Decoupling View Details
Quick view Details sku: sku-1006 Schloder MGA_B4 Current Transducer incl. Correction Network View Details
Quick view sku: sku-2132 EMIC-35 Current Injection Clamp for RF Conducted Immunity Testing The EMC Shop EMIC-35 Description: The preferred coupling and decoupling devices for IEC/EN 61000-4-6 RF conducted immunity testing are the CDNs, for reasons of test reproducibility and protection of the AE. However, if they are not suitable or available,... Add to Cart
Quick view sku: sku-1012 Schloder CN 1240-125 125A Coupling Network Schloder CN 1240-32 32A Coupling Network M2 – M5 acc. IEC / EN 610000-4-16 As described in IEC / EN 61000-4-16 at the frequency of the electrical power supply (either DC, 16,67Hz, 50Hz or 60Hz) the test stimuli are applied as both continuous and... Add to Cart
Quick view sku: sku-1011 Schloder CN 1240-32 32A Coupling Network Schloder CN 1240-32 32A Coupling Network M2 – M5 acc. IEC / EN 610000-4-16 As described in IEC / EN 61000-4-16 at the frequency of the electrical power supply (either DC, 16,67Hz, 50Hz or 60Hz) the test stimuli are applied as both continuous and... Add to Cart
Quick view sku: sku-1009 Schloder CDN CAN-BUS 150 kHz – 230 MHz Coupling / Decoupling Schloder CDN CAN-BUS 150 kHz – 230 MHz Coupling / Decoupling. Specifications Model CDN CAN-BUS RF IS Frequency Range (RF In) 150 kHz – 230 MHz Power Rating (RF In) 6 W (continuous) Decoupling attenuation (RF In – AE) PIN 2+7: > 35 dB (150 kHz – 230... Add to Cart
Quick view sku: sku-1006 Schloder MGA_B4 Current Transducer incl. Correction Network Testing Equipment According to EN 55103-255103-2 requires certain immunity tests for frequencies from 50 Hz to 10 kHz. The following test equipment fulfills all requirements according to EN 55103-2, annex B. Add to Cart
Quick view sku: sku-1005 Schloder MGA_B1 Common Mode Test Adapter Testing Equipment According to EN 55103-2 EN 55103-2 requires certain immunity tests for frequencies from 50 Hz to 10 kHz. The following test equipment fulfills all requirements according to EN 55103-2, annex B. Add to Cart
Quick view sku: sku-1004 Schloder MGA_HCS_100-60 100cm Helmholtz Coil Helmholtz Coils Several Helmholtz coils are available for susceptibility tests. Our company also offers tri-axial Helmholtz coils which are suitable for MGA1030. To achieve 1000 A/m at 1 kHz, it is absolute necessary to use our Helmholtz coils and an... Add to Cart
Quick view sku: sku-1003 Schloder MGA_HCST_50-28 50 / 46 / 42 cm Helmholtz Coil Helmholtz Coils Several Helmholtz coils are available for susceptibility tests. Our company also offers tri-axial Helmholtz coils which are suitable for MGA1030. To achieve 1000 A/m at 1 kHz, it is absolute necessary to use our Helmholtz coils and an... Add to Cart
Quick view sku: sku-1002 Schloder MGA_HCS_50-28 50cm Helmholtz Coil Helmholtz Coils Several Helmholtz coils are available for susceptibility tests. Our company also offers tri-axial Helmholtz coils which are suitable for MGA1030. To achieve 1000 A/m at 1 kHz, it is absolute necessary to use our Helmholtz coils and an... Add to Cart
Quick view sku: sku-1001 Schloder MGA_LS040 Loop Sensor Loop Sensor 40 mm (acc. to MIL-STD-461E RS101) including 3m Cable, Calibration Sheet. For immunity tests radiating loops are necessary to generate magnetic fields. Suitable loops are available. Measuring emissions require loop sensors which can also be... Add to Cart
Quick view sku: sku-1000 Schloder MGA_RL120 Radiating Loop Radiating Loop 120 mm (acc. to MIL-STD-461E RS101) including 3m Cable, Calibration Sheet. For immunity tests radiating loops are necessary to generate magnetic fields. Suitable loops are available. Measuring emissions require loop sensors which can also... Add to Cart
Quick view sku: sku-996 Schloder CAL 1250 50/60 Hz Magnetic Field Calibrator Schloder CAL 1250 50/60 Hz Magnetic Field Calibrator The magnetic field calibration device uses a triaxial Helmholtz coil to generate a three dimensional magnetic field. The CAL 1250 has three independent channels which each consists of an internal... Add to Cart