Voltage Dips and Interruptions Testers

Quick Links

Information

Viewed products

3ctest TIS 700x Compact Transient Immunity Simulator TIS View larger

3ctest TIS 700x Compact Transient Immunity Simulator TIS

New

  • 5.7 inch color touch screen front panel operation
  • Internal EFT/burst module 
  • Internal micro-pulse module 
  • As per ISO 7637 JASO SAE NISSAN 
  • Internal 60V/30A CDN(incl. load dump coupling, Max. Current up to 200A (200A customized) 
  • Via CN25 Control external load dump and battery simulation via CN25
  • DUT voltage and current detection and over current protection function
  • Emergency stop function 
  • internal mains switch 
  • Ethernet, RJ45 port for remote control, print and documentation.

More details

Request Quote/More Info

PDF Downloads

Test Equipment Description

The 3ctest TIS 700 Series for automotive transient unifies the capabilities of an EFT/Burst P3a/3b, micro pulse P1/2a and the required coupling network into one box. The TIS700 series are equipped to meet all international, car manufacturer specifications, and kinds of waveform modules can be customized as per user’s requirements. The current of built-in coupling network ranges up to 200A depending on the model. The built-in coupling network can be used and controlled by any unit of the LDS200 series, APG series and APS series to be the central EUT output port. Different simulators can be connected together via data bus and connected to PC via Ethernet to be a whole test system.

Standard:

  • BMW-(Airbag ECU)
  • BMW 600 13.0(Part 2)
  • BMW GS 95002(1999)
  • Case New Holland ENS0310
  • Chrysler PF-9326
  • Cummins 14269(982022-026)
  • DaimlerChrysler PF-10540
  • Audi(Reference vehicles)
  • Chrysler CS-11809(2009)
  • Chrysler CS-11979
  • Chrysler DC-11224 Rev.A
  • BMW GS 95002(2001)
  • ISO 7637-2 2001
  • ISO 7637-3-2016
  • GB/T 21437.2-2008
  • EN 301489-1
  • EN 301489-17
  • EN 300329
  • EN 300340
  • EN 301489-24
  • EN 300342-1
  • GJB 181A

Test connection:

Technical Parameters
Micro Pulse Module P1
Test voltage 3-600V
Test voltage Negative
Rise time Tr 0.5us - 1us
1.5us - 3us
No load
Duration Td 50us 土20% no load
12us 土20% matching load
1ms 土20% no load
1ms 土20% 50 ohm matching load
2ms土20% no load 1.5ms土20% 10 ohm matching load 0.2ms 土20% no load 0.3ms 土20% no load 0.5ms土20% no load
Source impedance 2Ω,4Ω,10Ω,30Ω,50Ω
Number of test 1-9999
DUT voltage monitoring 10:1
DUT current monitoring 10A:1V
Pulse interval 0.2s-60s (the shortest interval depends on output voltage)
Coupling mode ICC,DCC(50us 土20% no load waveform)
Micro Pulse Module P2a
Test voltage 3-150V
Test voltage Positive
Rise time Tr 0.5us - 1us 1.5us - 3us No load
Duration Td 50us 土20% no load
12us 土20% matching load  
Source impedance
Number of test 1-9999
DUT voltage monitoring 10:1
DUT current monitoring 10A:1V
Pulse interval 0.2s-60s (the shortest interval depends on output voltage)
Coupling mode ICC,DCC
EFT/Burst Module P3a/3b
Test voltage 25-700V
Polarity P3b positive,P3a negative
Rise time Tr 5ns土30% into 50 ohm load
5ns土30% into 1,000 ohm load
Duration Td 150ns - 45/+45ns into 50 ohm load
150ns - 45/+45ns into 1,000 ohm load
Source impedance 50Ω
Pulse number 1-200
Burst interval 50ms-999ms
Pulse frequency 0.1kHz-200kHz
Test duration 1s-50000s
Coupling mode CCC,DCC
Output Direct output By 50Ω coaxial connector (for test connected to capacitance coupling clamp)
General Parameters
Mains supply AC 110/220V,土10%,45-65Hz
Environment temperature 15-35°C
Relative humidity 35%-85%RH(no condensing)
Dimension Output current 30A: 4U
Output current  60A and 100A: 6U Output current 200A: 8U
Weight Approx. 20kg
Trigger Automatic, manual
Network Internal CDN 60V/30A current up to 200A
Input DUT supply DC voltage from APS, APG or other DC source
Pulse 5,7 TIS 700 network superimposing Pulse 5 and Pulse 7
Output LDS200 input Central DUT output port
Coaxial output port To connect capacitance coupling clamp as per ISO7637-3

Associated EMC Test Equipment

30 other products in the same category: