MIL-STD-461 CS117

CS117 Purpose

Conducted susceptibility, lightning induced transients, cables and power leads.

Military Standard 461 Version G's new section CS 117 requires multiple stroke surge testing using a lightning transient generator. This requirement is similar to the well established RTCA/DO-160 Section 22 lightning immunity test standard.

Test Equipmen...

CS117 Purpose

Conducted susceptibility, lightning induced transients, cables and power leads.

Military Standard 461 Version G's new section CS 117 requires multiple stroke surge testing using a lightning transient generator. This requirement is similar to the well established RTCA/DO-160 Section 22 lightning immunity test standard.

Test Equipment

The test equipment shall be as follows:

a. Lightning transient generator

b. Injection Transformers

c. Oscilloscope

d. Current monitor probes

e. Attenuators, 50 ohm, as needed on current monitor probes

f. Voltage monitor probes, high impedance

g. Monitor loop, low impedance wire loop

h. Calibration loop, low impedance wire loop

i. Capacitor, >28,000 µF for DC power inputs

j. LISN

Get Application Support, Pricing, Lead Time and More: Contact Form

More

MIL-STD-461 CS117 There are 21 products.

per page
Showing 1 - 12 of 21 items
    • Meets RTCA/DO 160 Section 22 Levels 1-5
    • Pre-Programmged Test Procedures
    • Intelligent Mains Controlled by Program, Stable Charging w/ High Effeciency
    • Auto Safety Protection Program
    Request Quote/More Info
    • Meets RTCA/DO 160 Section 22 Levels 1-5
    • Meets MIL-STD-461G CS 117 Levels 1-5
    • Pre-Programmed Test Procedures
    • On-site Installation, Debugging and Training
    • Intelligent Mains Controlled by Program, Stable Charging w/ High Efficiency
    • Auto Safety Protection Program
    Request Quote/More Info
    • Modular design 
    • Single rack portability 
    • Programmable single stroke, multiple stroke, multiple burst waveforms 
    • Pin injection, cable bundle injection, ground injection up to Level 3 
    • Self-contained microprocessor control 
    • LCD system display
    • lightning induced transient susceptibility testing
    • requirements of RTCA/DO-160E/F/G Section 22 are met at Levels 1 through 3
    Request Quote/More Info
    • Frequency range: 10 kHz to 500 MHz
    • Transfer impedance (ZT): 1.0 to 5.0 Ω above 300 kHz
    • Output load impedance: 50 + j 0 Ω
    • Continuous signal current (CW): 40 A
    • Maximum power current: 200 A DC to 400 Hz
    Request Quote/More Info
    • Frequency range 2 MHz to 500 MHz
    • Maximum input power 200 watts (see note)
    • Maximum input current 50 Amperes
    • Maximum time at full power 30 minutes

    Request Quote/More Info
    • Frequency range: 1 kHz - 200 MHz
    • Transfer impedance (ZT): .001
    • Continuous signal current (CW): 50 A

    Request Quote/More Info
    • Sample Rates Up to 5 GS/s on All Channels
    • 10 Megasample Record Length on All Channels
    • 3,700 wfms/s Maximum Waveform Capture Rate
    • Built-in Ethernet Port



    Request Quote/More Info
    • High-resolution touchscreen
    • Fully customizable display
    • Fast access to important tools
    • Signal details at your fingertip
    • Fast access to instrument setups
    • Documentation at the push of a button
    Request Quote/More Info
    • Waveform Output:
      • W2
      • W3
      • W6
    • PIN Injection Test
    • Cable Bundle Test (single stroke & multiple stroke)
    • RTCA DO-160 Section 22 Compliant
    Request Quote/More Info
  • Request Quote/More Info
  • Request Quote/More Info
  • Request Quote/More Info
Showing 1 - 12 of 21 items