Rent Com-Power CLCE-400 Emissions Probe for CISPR, MIL-STD 461, DO-160

Top Frequency Range:
400 MHz
AC Current Handling (DC-400Hz):
800 Amps
RF Current Handling (CW/Pulse):
100/200 Amps
Style:
Clamp On (Fixed Window)
Diameter:
1.25"
Transfer Impedance:
1 Ohm
Test Standards:
MIL 461 CE101 "Weight=0.275 lbs. (0.125 kg)"
Connector type:
Type-N (Female)
Current Rating:
Max Primary Current (DC-400 Hz): 100 Amps, Max Primary Current (RF): 4 Amps
Dimensions:
Height: 0.76" (19.3 mm)
Frequency range:
10 kHz to 400 MHz
Operating Temperature:
Max. Core Temperature: 248℃F (120°C)
Probes:
Current monitoring
Style:
split-core ferrite in a circular hinged enclosure
Transfer impedance (ZT):
Transfer impedance (ZtΩ): 7Ω Transfer impedance (dBΩ): -21 to 17 dBΩ (typical)
Window diameter:
Window (Aperture) Diameter: 1.25" (32 mm), Outside Diameter: 2.83" (72 mm)
Manufacturer:
Com-Power
Online Orders Ship Same Day

 

Description

The CLCE-400 RF Current Probe is part of Com-Power's extensive line of radio frequency conducted emission/ immunity test equipment and calibration accessories. The CLCE-400 is suitable for complaince measurements required by CISPR 22, CISPR 32, DO-160, Mil Std 461 etc, as well as for applied current monitoring during conducted immunity tests.

It's design incorporates a split-core ferrite in a rugged, circular hinged enclosure; thereby allowing the probe to be opened on one side in order to easily place the wire, cable(s) or cable bundle(s) to be tested into the probe window, making the CLCE-400 much more convenient to use than other non-split core probes. The CLCE-400 is designed to be used in conjunction with a spectrum analyzer or EMI receiver or any 50? impedance measurement equipment, which measure magnitude quantities in terms of true rms voltage.

The Transfer Impedance conversion factor, defined as the ratio of secondary voltage to the primary current, is usually expressed in terms of dB over 1Ω, It is used to convert the voltage quantity into a current quantity, expressed in terms of dB over 1 uA.
transfer impedance conversion: [dBuV] - [dBΩ] = [dBuA]

The conversion factor may also be derived from the Transfer Admittance value, expressed in terms of dB over 1 S.
transfer admittance conversion: [dBuV] + [dB(S)] = [dBuA]

Application

In general, RF current probes are employed to monitor, or measure, the asymmetrical disturbance RF currents on a wire, cable or cable bundle without making direct conductive contact with the source conductor. The current is measured inductively by clamping the probe around the conductor(s) to be tested. No actual contact is made with the conductor(s), and the insulation is left in place. Essentially, a current probe is a torroidal transformer where the conductor(s) act as a single turn primary, and the probe as a multiple turn secondary.

Current Probe Calibration Fixture

Current probes are calibrated through the use of a calibration fixture which provides a 50Ω coaxial-type transmission line arrangement. The fixture allows the probe to be clamped around the center conductor, while the outer conductor encapsulates the probe on four sides, so that the transmission line characteristics are not compromised. See calibration fixture picture on the following page.

FCLCE-1000 Calibration Fixture (optional) is specifically designed to provide a nominal 50Ω transmission line for the CLCE-400. The fixture is required for calibration of the Transfer impedance, insertion loss and VSWR parameters.

Calibration

Individual NIST traceable calibration is performed on each unit, and the data is provided along with certificate of calibration. ISO 17025 accredited calibration is available for an additional charge.

Typical Transfer Impedance Data

Com-Power CLCE-400 Transfer Impedance

Equipment Specifications

Manufacturer:
Com-Power
Top Frequency Range:
400 MHz
AC Current Handling (DC-400Hz):
800 Amps
RF Current Handling (CW/Pulse):
100/200 Amps
Style:
Clamp On (Fixed Window)
Diameter:
1.25"
Transfer Impedance:
1 Ohm
Test Standards:
MIL 461 CE101 "Weight=0.275 lbs. (0.125 kg)"
Connector type:
Type-N (Female)
Current Rating:
Max Primary Current (DC-400 Hz): 100 Amps, Max Primary Current (RF): 4 Amps
Dimensions:
Height: 0.76" (19.3 mm)
Frequency range:
10 kHz to 400 MHz
Operating Temperature:
Max. Core Temperature: 248℃F (120°C)
Probes:
Current monitoring
Style:
split-core ferrite in a circular hinged enclosure
Transfer impedance (ZT):
Transfer impedance (ZtΩ): 7Ω Transfer impedance (dBΩ): -21 to 17 dBΩ (typical)
Window diameter:
Window (Aperture) Diameter: 1.25" (32 mm), Outside Diameter: 2.83" (72 mm)

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.