Description
EM Test UCS 500M4 Description:
This EM Test UCS 500-M4 is configured for EFT/Burst only and complies to edition 1 of IEC 61000-4-4. The output at HV complies with edition 3 but the waveform at the CDN is slightly out of tolerance, however still suitable for precompliance testing.
The EM Test UCS 500M4 is a previous generation transient generator suitable for precompliance testing to IEC 61000-4-4, IEC 61000-4-5 and IEC 61000-4-11. The distinct operation features, convenient DUT connection facilities, a clearly arranged menu structure and display philosophy as well as the pre-programmed standard test routines make testing easy, reliable and safe. Extendable by a variety of test accessories the UCS 500M4 is a universal equipment for abroad range of recommendations even for three-phase applications up to 100A.
Videos
Custom Field
Applications EFT/Burst Testing, Dips Interrupts & Variations, EMC Precompliance Testing
Standards Met IEC 61000-4-4, IEC 61000-4-11
Max EUT AC Voltage (w/ Built in CDN) 250 Volts
Max EUT AC Current (w/ Built in CDN) 16 Amps
Max EUT DC Voltage (w/ Built in CDN) 250 Volts
Max EUT DC Current (w/ Built in CDN) 10 Amps
EFT/Burst Pulse Output Capability 4.4 kV
Dips & Interrupts 16 – 500 Hz