Description
IEC/EN 61000-4-6 specifies the design and performance of a range of coupling/decoupling networks
(CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Use the Teseqs (Schaffner) CDN T002 for a simple and reliable method of injecting RF energy into the equipment under test (EUT) on a pair of unshielded balanced lines.
Videos
Custom Field
Application/Test Type EMC testing for unscreened data communication/telecom lines (Power over Ethernet, 1100BaseT4, 100Base VG-AnyLan,
1000BaseT, Token ring, ISDN,
10BaseT, 100BaseTX, ATM, FDDI,
TP-PMD
Current Rating 1.5 Amps (3/5 Amp models available)
Frequency Range 150 kHz to 230 MHz (limited to 80 MHz on 3/5 Amp models)
Mains & EUT Connections Banana, XLR, RJ45, RJ11
RF Connector BNC, 50 Ω
RF Input Voltage 30 Volts Max
Standards Met IEC 61000-4-6
Voltage Rating AC max. voltage (line to ground): 63 Volts
DC max. voltage (line to ground): 100 Volts
Test voltage: 200 VDC, 2 s