EN/IEC 61000-4-6

(Showing 12 of 25)
Show 12 24
  • SKU: sku-2132

    EMIC-35 Current Injection Clamp for RF Conducted Immunity Testing

    Weight: approx. 14 kg
    Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive coupling
    Clamp factor (CF): -.6 dB at 100 kHz to -2.2 dB at 1 GHz (Min -4 dB at 700 MHz
    Connector: N-type female
    Dimensions: 666 mm x 135 mm x 120 mm
    Frequency Range: 10 kHz to 1000 MHz
    Impedance: 50 Ohms
    Max. Cable Diameter: 35 mm
    Maximum Continuous Power: 0.15 to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 5 min; 230 to 1000 MHz: 50 W for 3 min
    Standards Met: IEC/EN 61000-4-6; CISPR 24; EN 61000-6-1; EN 61000-6-2; IEC 60533; IEC 60601-1-2; IEC 61326
  • EM Test

    SKU: sku-921

    Monthly Rental EM Test CWS 500N Continuous Wave Simulator for IEC 61000-4-6

    Weight: 17 kg (37.5 Pounds)
    Application/Test Type: Create and output RF currents as well as measure input for CDN and clamp calibration as well as current monitor for clamp applications
    Dimensions: 19"/3 HU
    Frequency Range: Sinus (CW) 100kHz to 300MHz Frequency bands 100kHz to 9.999MHz 10MHz to 99.99MHz 100MHz to 300MHz
    Impedance: 50 Ohms
    Input: 115 V to 230 V +10/-15 %, 50/60 Hz (380 Watts Max)
    Maximum Continuous Power: 80W (nominal)
    Standards Met: IEC 61000-4-6
    Test Routines: Quick Start, User Test Routines, Standards Test Routines (IEC/EN 61000-4-6), Cal Procedure, Service
    Voltage Rating: 1 V to 30 Volts Max
  • Teseq

    SKU: sku-862

    Teseq CDN T8 Coupling/Decoupling Network for RJ 11, RJ45 PoE 1Gbps Testing

    Common Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω
    Current Rating: 500mA (line), 1.2A (pair)
    Decoupling of Common Mode Disturbance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 80 MHz: 150 Ω +60 Ω / -45 Ω
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: 50 Ohm Female BNC
    RF Connector: 50 Ω BNC (Female)
    RF Input Voltage: 15 Volts Max
    Standards Met: IEC / EN 61000-4-6
    Voltage Division Factor: 9.5 dB ±1 dB
    Voltage Rating: 63 V AC / 100 V DC (Line to Ground)
  • Teseq

    SKU: sku-851

    Teseq CDN S751A 75 Ohm BNC RF Coupler for IEC 61000-4-6 Testing

    Weight: 1.5 kg (3.3 lbs)
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 1000 mA maximum
    Decoupling of Common Mode Disturbance: 150 kHz: Over 60 dB; 1.5 MHz: Over 60 dB; 30 MHz: Over 50 dB; 230 MHz: Over 40 dB (refer to data sheet for some exceptions)
    Dimensions: 4 x 4 x 9.5 inches (10 cm x 10 cm x 24 cm); (CDN HDMI and CDN S752A: 28.8 cm 11 inches)
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: BNC 75 Ω
    RF Connector: BNC 75 Ω
    RF Input Voltage: 20 Volts Max
    Standards Met: IEC 61000-4-6
    Voltage Division Factor: 10 dB ±1 dB to 80 MHz, 10 dB +3, -2 dB from 80 MHz to 230 MHz
    Voltage Rating: AC max. voltage (line to ground): 250V; DC max. voltage (line to ground): 400 V; Test voltage: 200 V - 750 V DC, 2 sec (refer to data sheet for exact model specifications)
    $1,245.00
  • Teseq

    SKU: sku-828

    Teseq CDN S900S RS-232 Coupling Decoupling Network for IEC 61000-4-6

    Weight: 1.5 kg (3.3 lbs)
    Application/Test Type: Coupling / decoupling network (CDN) for screened data/telcom lines or coaxial cables
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 250 mA (CDN ST08 1 Amp)
    Decoupling of Common Mode Disturbance: 150 kHz: Over 60 dB; 1.5 MHz: Over 60 dB; 30 MHz: Over 50 dB; 230 MHz: Over 40 dB (refer to data sheet for some exceptions)
    Dimensions: 4 x 4 x 9.5 inches (10 cm x 10 cm x 24 cm); (CDN HDMI and CDN S752A: 28.8 cm 11 inches)
    Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230 MHz
    Mains & EUT Connections: BNC 50 Ω, N 50 Ω, BNC 75 Ω, N 75 Ω, XLR 3 pins, DIN 5 pins, RJ45, D-Sub 9 pins, D-Sub 15 pins, D-Sub 25 pins, HDMI (refer to data sheet for exact model specifications)
    RF Connector: BNC 50 Ω
    RF Input Voltage: 20 Volts Max
    Standards Met: IEC 61000-4-6, CISPR 22, IEC 60601-1-2
    Voltage Division Factor: 9.5 dB to 10 dB ±1 dB (refer to data sheet for some exceptions)
    Voltage Rating: AC max. voltage (line to ground): 100 V - 250V; DC max. voltage (line to ground): 150 V - 400 V; Test voltage: 200 V - 750 V DC, 2 sec (refer to data sheet for exact model specifications)
    $1,190.00
  • SKU: sku-524

    EMIC-20 EM Injection Clamp for IEC/EN 61000-4-6 Immunity Test

    Standards: EN/IEC 61000-4-6
    Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive coupling
    Clamp factor (CF): -.5 dB at 100 kHz to -4 dB at 1 GHz (Min -7 dB at 700 MHz
    Connector: N-type female
    Dimensions: 632 mm x 120 mm x 80 mm
    Frequency Range: 10 kHz to 1000 MHz
    Max. Cable Diameter: 20 mm
    Maximum Continuous Power: 0.15 to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 5 min; 230 to 1000 MHz: 50 W for 3 min
    Typically In Stock
  • EM Test

    SKU: sku-410

    EM Test CWS 500N1 Continuous Wave Simulator for IEC 61000-4-6

    Weight: 17 kg (37.5 Pounds)
    Application/Test Type: Create and output RF currents as well as measure input for CDN and clamp calibration as well as current monitor for clamp applications
    Dimensions: 19"/3 HU
    Frequency Range: Sinus (CW) 100kHz to 300MHz Frequency bands 100kHz to 9.999MHz 10MHz to 99.99MHz 100MHz to 300MHz
    Impedance: 50 Ohms
    Input: 115 V to 230 V +10/-15 %, 50/60 Hz (380 Watts Max)
    Maximum Continuous Power: 80W (nominal)
    Standards Met: IEC 61000-4-6
    Test Routines: Quick Start, User Test Routines, Standards Test Routines (IEC/EN 61000-4-6), Cal Procedure, Service
    Voltage Rating: 1 V to 30 Volts Max

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.