RTCA DO-160

DO-160, Environmental Conditions and Test Procedures for Airborne Equipment is a standard for the environmental testing of avionics hardware. It is published by the Radio Technical Commission for Aeronautics (RTCA).

Common RTCA DO-160 Test Equipment:

Lightning Surge Test Systems

Line Impedance Stabilization Networks (LISN's)

Current Injection Probes

AC Power Sources & more

Get Application Support, Pricing, Lead Time and More: Contact Form

RTCA DO-160 There are 44 products.

Subcategories

  • RTCA DO-160 Section 22

    RTCA DO-160 Section 22 covers the transient current and voltage spike introduced into electronics cables as a result of the magnetic field generated by a large surge of charge traveling through the frame of the aircraft. Sometimes called a lightning transient or lightning induced effect.

    There are multiple test levels depending on the enviroment ranging from Well-protected environment to Severe electromagnetic environments.

    RTCA DO-160 Section 22 Injection Methods:

    Pin Injection – This method is used to directly inject the waveform into connector pins of both cables and printed wiring boards 

    Cable Bundle Induction – This method uses a coupling transformer to inductively couple the waveform onto the cable bundle 

    Ground Injection – This method is often used as an alternate method to inject the waveform onto the ground wire of the unit under test, referenced to the Ground plane that is located on the surface of the test table.

    RTCA DO-160 Section 22 Waveforms:

    WaveformWaveform TypeSpecifications
    W16.4/69Current Wave
    W20.1/6.4Voltage Wave
    W31MHz/10MHzVoltage Wave
    W46.4/69Voltage Wave
    W5A40/120Current Wave
    W5B50/500Current Wave
    W60.25/4 Current Wave

    RTCA DO-160 Section 22 Waveform Power Levels

    There are five Test Power Levels, where Level 1 is the lowest and Level 5 is the highest.

    Level 1

    • Equipment and wiring are installed in a well protected environment

    Level 2

    • Equipment and wiring are in a partially protected environment

    Level 3

    • Equipment and wiring are in a moderate electromagnetic environment

    Level 4 and 5

    • Equipment and wiring are in severe electromagnetic environments

    Get Application Support, Pricing, Lead Time and More: Contact Form

per page
Showing 1 - 12 of 44 items
    • Meets RTCA/DO 160 Section 22 Levels 1-5
    • Meets MIL-STD-461G CS 117 Levels 1-5
    • Pre-Programmed Test Procedures
    • On-site Installation, Debugging and Training
    • Intelligent Mains Controlled by Program, Stable Charging w/ High Efficiency
    • Auto Safety Protection Program
    5-6 Months
    Request Quote/More Info
    • Monthly Rental - Ships Immediately
    • CDN, BCI Probe or EM Clamp Required to complete test setup
    • Meet RF & Conducted Immunity Compliance Standards:
      • EN/IEC 61000-4-6
      • MIL-STD461 CS114
      • RTCA/DO160 Section 20
      • ISO 11452 part 4 BCI
      • ISO 11452 part 5 Stripline
      • IEC 60601-1-2
      • EN 61000-6-1/EN 61000-6-2
      • Various Automotive Manufacturer's Specifications
    In Stock
    Request Quote/More Info
    • Meets RTCA/DO 160 Section 22 Levels 1-5
    • Pre-Programmged Test Procedures
    • Intelligent Mains Controlled by Program, Stable Charging w/ High Effeciency
    • Auto Safety Protection Program
    4-6 Weeks
    Request Quote/More Info
    • Integrated signal generator 80 MHz to 6 GHz
    • Integrated RF switch network
    • Integrated 3 freely configurable pulse modulators (1 μs to 200 s) for radar pulse profiles
    • Multiple EUT monitoring options
    • 3.5“ TFT color display
    • Safety interlock function
    • Remote control via USB, RS232 or LAN
    Typical Lead Time 6 - 8 Weeks
    Request Quote/More Info
    • Rentals Ship Immediately
    • 6 kVA, 3 Phase Output
    • Easy Software for Operation
    • Power line Disturbance Simulation
    • Harmonics, Intermonics Synthesis
    • Pre-programmed Tests
      • MIL-STD-704
      • RTCA DO-160
      • Airbus-A350 ABD0100
      • IEC 61000-4-11
      • IEC 61000-4-13
      • IEC 61000-4-14
      • IEC 61000-4-28
    $1,295.00
    In Stock
    Request Quote/More Info
    • Modular design 
    • Single rack portability 
    • Programmable single stroke, multiple stroke, multiple burst waveforms 
    • Pin injection, cable bundle injection, ground injection up to Level 3 
    • Self-contained microprocessor control 
    • LCD system display
    • lightning induced transient susceptibility testing
    • requirements of RTCA/DO-160E/F/G Section 22 are met at Levels 1 through 3
    4-6 Weeks
    Request Quote/More Info
    • Price is for a pair of LI-125A line impedance stabilization networks
    • Fully compliant to RTCA DO-160 / MIL-STD 461D
    • "Air-core" inductors to prevent saturation
    • Provides a near 1:1 (<0.5 dB insertion loss) 50Ω coaxial measurement port (type-N)
    • Provides a defined, stable, impedance to the Equipment Under Test (EUT)
    • Individual Calibration Included
    • Three Year Warranty
    $1,525.00
    Typically In Stock
    Request Quote/More Info
    • Used Purchase Price: $1199.00
    • MSRP Price: $1560.00
    • Price is for a pair of LI-125A line impedance stabilization networks
    • Fully compliant to MIL-STD 461
    • Provides a near 1:1 (<0.5 dB insertion loss) 50Ω coaxial measurement port (type-N)
    • Provides a defined, stable, impedance to the Equipment Under Test (EUT)
    • Individual Calibration Included
    • Three Year Warranty
    $1,199.00
    Typically In Stock
    Request Quote/More Info
    • Broad Frequency Range of 10 KHz to 100 MHz
    • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 8 to 30 dB
    • Max Input Power: 100 Watts
    • Connector: N-type, Female
    • Aperture: 1.5" (38mm)
    • Diameter: 4.25" (108mm)
    • Weight: 4.2 lbs (1.9 kg)
    Typically In Stock
    Request Quote/More Info
    • Broad Frequency Range of 2 MHz - 500 MHz
    • Measures currents on 50 Hz, 60 Hz and 400 Hz powerlines
    • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 4 to 16 dB
    • Transfer Impedance: 16 to 31 dBW
    • Max Input Power: 200 Watts
    Typically In Stock
    Request Quote/More Info
    • Broad High Frequency Response: 5 MHz - 1 GHz
    • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
    • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 5 to 30 dB
    • Max Input Power: 50 Watts
    • Mas Current: 30 Amps
    Typically In Stock
    Request Quote/More Info
    • In Stock, Calibrated and Ready to Ship
    • Prices are on a Per Month Basis
    • Broad High Frequency Response: 300 kHz - 1 GHz
    • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
    • Measures currents on 50 Hz, 60 Hz and 400 Hz power lines
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe
    $195.00
    In Stock
    Request Quote/More Info