ISO 11452

ISO 11452 consists of the following parts, under the general title Road vehicles — Component test methods for electrical disturbances from narrowband radiated electromagnetic energy:

  • — Part 1: General principles and terminology
  • — Part 2: Absorber-lined shielded enclosure
  • — Part 3: Transverse electromagnetic mode (TEM) cell
  • — Part 4: Harness excitation methods
  • — Part 5: Stripline
  • — Part 7: Direct radio frequency (RF) power injection
  • — Part 8: Immunity to magnetic fields
  • — Part 9: Portable transmitters
  • — Part 10: Immunity to conducted disturbances in the extended audio frequency range
  • — Part 11: Reverberation chamber

ISO 11452 There are 26 products.

Subcategories

  • ISO 11452-2 Absorber-Lined Shielded Enclosure

    The EMC Shop specializes in automotive radiated and conducted emissions and susceptibility testing. Rent, buy or lease ISO 11452-2 Absorber-Lined Shielded Enclosure Equipment.

  • ISO 11452-4 BCI Test

    The EMC Shop specializes in automotive radiated and conducted emissions and susceptibility testing. Rent, buy or lease ISO 11452-4 BCI Test Equipment.

    ISO 11452-4 defines harness excitation methods (BCI testing) for road vehicles; the component test methods for electrical disturbances from narrowband radiated electromagnetic energy.

  • ISO 11452-7 Direct RF Injection

    The EMC Shop specializes in automotive radiated and conducted emissions and susceptibility testing. Rent, buy or lease ISO 11452-7 Direct Radio Frequency (RF) Injection Test Equipment. 

  • ISO 11452-8 Magnetic Immunity

    Rent, buy or lease ISO 11452-8 Magnetic Immunity Test Equipment. The EMC Shop specializes in military and aerospace compliance testing.

  • ISO 11452-10 Immunity to Audio Frequencies

    The EMC Shop specializes in automotive radiated and conducted emissions and susceptibility testing. Rent, buy or lease ISO 11452-10 Immunity Test Equipment to Audio Frequencies. 

    Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 10: Immunity to conducted disturbances in the extended audio frequency range

    ISO 11452-10:2009 specifies a conducted voltage test method and procedure for determining the immunity of electronic components of passenger cars and commercial vehicles, regardless of the propulsion system (e.g. spark-ignition engine, diesel engine, electric motor). The method is applied to each individual device under test (DUT) lead and is applicable to all power and output leads, as well as low frequency analogue leads. The method is particularly useful in evaluating DUTs with acoustic or visible display functions.

    The disturbances considered in ISO 11452-10:2009 are limited to continuous narrowband electric voltage waveforms.

per page
Showing 1 - 12 of 26 items
    • Most compact equipment for ripple noise on ac/dc supplies and magnetic fields
    • Built-in LF signal generator
    • Built-in LF amplifier
    • Built-in LF transformer 2:
    • Built-in frequency-selective voltage and current meter
    • Built-in load resistors
    • Automatic self-calibration
    • Frequency Range: 10 Hz - 250 kHz
    In Stock
    Request Quote/More Info
    • Complete kit for ISO 11452-3 EMC Testing
    • Test methods include:
      • Signal Generator
      • RF Power Meter
      • Broadband Amplifier
      • Couplers
      • TEM Cell
    4-6 Weeks
    Request Quote/More Info
    • Monthly Rental - Ships Immediately
    • CDN, BCI Probe or EM Clamp Required to complete test setup
    • Meet RF & Conducted Immunity Compliance Standards:
      • EN/IEC 61000-4-6
      • MIL-STD461 CS114
      • RTCA/DO160 Section 20
      • ISO 11452 part 4 BCI
      • ISO 11452 part 5 Stripline
      • IEC 60601-1-2
      • EN 61000-6-1/EN 61000-6-2
      • Various Automotive Manufacturer's Specifications
    In Stock
    Request Quote/More Info
    • Integrated signal generator 9 kHz to 1 GHz
    • 3 power meter inputs 9 kHz to 1 GHz
    • Integrated power amplifier module for different applications
    • Multiple EUT monitoring options
    • Optional built-in amplifier up to 75 watts (150 kHz - 230 MHz)
    • Meet IEC 61000-4-6,  IEC 61000-4-3, IEC 61000-4-20, IEC 61000-4-21 
    • Meet Mil-STD 461 CS114
    In Stock
    Request Quote/More Info
    • Compact Design
    • Touch Screen Color display
    •  Input over-drive protection 
    • Whisper mode – adjusts fan speed according to heatsink temperature
    • USB, Ethernet, GPIB, RS232 and TTL interface
    • Gain Control
    • Three year warranty
    4-6 Weeks
    Request Quote/More Info
    • Compact Design
    • Touch Screen Color display
    • Input over-drive protection
    • Whisper mode – adjusts fan speed according to heatsink temperature
    • USB, Ethernet, GPIB, RS232 and TTL interface
    • Gain Control
    • Three year warranty
    4-6 Weeks
    Request Quote/More Info
    • 100 kHz to 200 MHz frequency range
    • Multi standard design
    • 150 A max output current
    • Suitable also for DC lines
    • Large baseplate for optimal grounding
    • Robust, compact construction
    • Screw terminals for safe wiring
    • Meets the requirements of several standards including CISPR 16-1-2, CISPR 25,
    • ISO 11452-2/4/5, ISO 7637-2, MIL-STD-461F, DO-160, ED-14G
    Typically Stocked
    Request Quote/More Info
    • 10 kHz to 400 MHz frequency range
    • Multi standard design
    • 150 A max output current
    • Suitable also for DC lines
    • Large baseplate for optimal grounding
    • Robust, compact construction
    • Screw terminals for safe wiring
    • Meets the requirements of several standards including CISPR 16-1-2, CISPR 25,
    • ISO 11452-2/4/5, ISO 7637-2, MIL-STD-461F, DO-160, ED-14G
    Typically Stocked
    Request Quote/More Info
    • Complete kit for ISO 11452-4 EMC Testing
    • Test methods include
      • Bulk Current Injection (BCI)
      • Tubular Wave Coupler (TWC)
    4-6 Weeks
    Request Quote/More Info
    • Complete kit for ISO 11452-2 EMC Testing
    • Test equipment needed
      • Absorber lined chamber
      • Broadband Power Amplifier
      • Antennas
      • Field generator
      • Test bench
    4-6 Weeks
    Request Quote/More Info
    • Complete kit for ISO 11452-5 EMC Testing
    • Test methods include:
      • Stripline
      • Broadband Power Amplifier
      • RF Signal Generator
      • Couplers
    4-6 Weeks
    Request Quote/More Info
    • Complete kit for ISO 11452-8 EMC Testing
    • Test equipment includes:
      • field generating device (radiating loop or Helmholtz coils)
      • magnetic field intensity monitor
      • low frequency (LF) generator
      • low frequency (LF) amplifier
      • voltmeter
      • current monitor
      • artificial network
    4-6 Weeks
    Request Quote/More Info
Showing 1 - 12 of 26 items