RF Conducted Test Equipment

 

EMC/EMI Testing Services              Bulk Current Injection Testing              RF Conducted Testing Services

 

RF conducted testing is an efficient manner to test immunity along power and data lines up to 1 GHz. Common bandwidths range from 10kHz to 400 MHz, where the ~80 MHz range and higher acts as a good alternative to radiated immunity testing requiring high power RF amplifiers.



The EMC Shop stocks calibrated RF conducted test equipment and builds custom solutions to fit the customer DUT and test requirements. Rent or buy a custom solution taylored to your DUT and testing parameters. Software is included and custom test sequences will be generated by The EMC Shop staff prior to shipment.



Get Application Support, Pricing, Lead Time and More: CONTACT FORM



Pulse generators are supplied with the ancillary equipment called out in specific test setups. Supplying the test diagram ensures the correct solution is provided. It is also to important to distinguish what tests are required vs what tests would be nice to accomplish but not essential.

Video RF Conducted Setup, Calibration & Test

RF Conducted Test Equipment There are 23 products.

Subcategories

  • RF Conducted Immunity Test Generators

    The EMC Shop stocks a variety of RF conducted immunity test generators used in conducted immunity testing and compliance. These systems have integrated signal generators, RF amplifiers and power sensors, keeping hardware minimal for tests such as IEC 61000-4-6ISO 11452-4 and MIL-STD-461 CS114.

    RF Conducted Immunity Test Setup vs Test Generator

    Typical RF Conducted Immunity Test Setup

    RF Conducted Immunity Test Equipment Typical Setup

    RF Conducted Immunity Test Setup Using All-in-one Generator

    RF Conducted Immunity Test Generator

  • EMC CDN's (Coupling / Decoupling Networks)

    The EMC Shop stocks all types of CDN's for EMC testing, typically used for RF conducted immunity testing per IEC 61000-4-6, which is one of the EMC (electromagnetic compatibility) phenomenon tests typically required for “CE-mark” compliance testing of commercial products. Rent or buy individual coupling/decoupling networks or order a complete turn key system for RF conducted immunity testing.



    Get Application Support, Pricing, Lead Time and More: Contact Form



    Coupling networks typically have a BNC port top-side where your inject the RF signal, an EUT side where the RF disturbances are directed via direct injection to power lines or data lines via most common connectoy ports including USB, RJ45, and HDMI. The AE Side is safe from disturbance and used to connect and monitor auxilary equipment to the DUT.



    EMC CDN Type's

    • M Type: Used for unscreened AC or DC power supply applications.
    • AF Type: Used for all unscreened, unbalanced lines, carrying low current.
    • CAN bus Type: Specially designed to test the unscreened CAN bus.
    • S Type: Used for screened cables.
    • S Type coaxial: Used for coaxial cables.
    • S Type for USB and HDMI: Specially designed to test the USB and HDMI
    • ST type: Used for testing screened, balanced lines for telecommunication ports on ITE equipment.
    • T type: Used for unscreened, balanced lines for telecommunication ports on ITE equipment.

    RF Conducted Immunity CDN Test Setup

    EMC RF CDN Test Setup for Conducted Immunity Testing

  • Bulk Current Injection (BCI) Probes

     

    Bulk Current Injection Testing         EMC/EMI Testing Services         Rent EMC Test Equipment          Antenna Testing

     

    Injecting low level RF signals and high frequency current into wires and cable bundles are a common requirement in ISO 11452-4, Mil-STD-461, RTCA/DO-160 and EN/IEC 61000-4-6. Bulk current injection probes are available in two styles, a window style for passing wires and cables through and a clamping style BCI probe for hard to access cable bundles or more intricate systems.

    Get Application Support, Pricing, Lead Time and More: Contact Form

    Bulk Current Injection (BCI) Probes Test Setup

    Bulk Current Injection (BCI) Probes Test Setup

  • Current Monitor/Sensing Probes

    Typically used in tantum with bulk current injection (BCI) probes. A broadband current monitoring/sensing probe is used downstream to evaluate and monitor changes in characteristics once a low level RF/high frequency current was injected into the line or cable bundle. Typical applications include Mil-STD-461 CS101, CS102, RTCA-DO-160 and EN/IEC 61000-4-6.

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • RF Current Probe Calibration Fixtures

    Order RF Current Probe Calibration Fixtures for monitoring probes. The EMC Shop is the only online store for electromagnetic compliance test equipment and accessories.

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • EM Coupling Clamps

    The integrity of both communication and electrical lines within products of all shapes and sizes is important to address early in design stages. EM coupling clamps are used to monitor electrical and magnetic characteristics radiated from electrical/communication wires. Additional, you can generate electrical and magnetic fields using a clamp to inject distrubances onto the lines and evaluate their response. EM clamps are used to meet CISPR, IEC and other compliance standards to evaluate radio frequency disturbances on and around power or data lines.

    Get Application Support, Pricing, Lead Time and More: Contact Form

    EM Clamp Test Setup per IEC 61000-4-6

    EM Coupling Injection Clamp Test Setup per IEC 61000-4-6

    EM Injection Clamp Video Overview

per page
Showing 13 - 23 of 23 items
  • Request Quote/More Info
    • For use with one, two, three, or four unscreened balanced pairs
    • Refers schematic circuit example in CISPR 22/32 Figure D.3/G.3
    • Intended for connection to cable category 3 and 5
    • 1000BaseT and PoE application
    • Changeable pin-arrangements with RJ11 and RJ45
    Request Quote/More Info
    • Frequency Range 10 kHz to 400 MHz
    • Includes:
      • Pearson 8700i Current Injection Probe
      • Pearson 8705 Current Monitor
      • Pearson F-3 Calibration Jig
    • MIL-STD-461 CS114, CS115, CS116
    • DO-160 Section 21, rf CE (8705C)
    • AIAA S-121 Radio Frequency CS
    • NASA GSFC EMI Specs CE03, Bulk current emission
    • Automotive Chrysler Radio Frequency CE
    • John Deere Radio Frequency CE
    • BMW Radio Frequency CE
    • IEC / EN 61000-4-6
    • TR-102323 Radio Frequency CS
    Request Quote/More Info
    • In stock, calibrated and ready to ship
    • Turnkey CDN, BCI and EM Clamp solutions for IEC 61000-4-6
    • 35 Watt, 150kHz to 230 MHz Integrated class A power amplifier (See Teseq NSG4070-45 for expanded capabilities)
      Multiple EUT monitoring options
    • 5.7“ TFT color display
    • Internal, menu-based control software
    • Basic remote control software and report generator included
    • Whisper mode
    Request Quote/More Info
    • Most compact equipment
    • Supports BCI testing as per various standard requirements
    • Basic frequency range 9 kHz up to 400 MHz
    • Extendable frequency range up to 1 GHz
    • Built-in 110 W class A amplifier up to 400 MHz
    • Built-in RF switch to connect external amplifier
    • Built-in directional coupler
    • Built-in 3-channel power meter up to 1 GHz
    Request Quote/More Info
    • 30 MHz - 1 GHz Frequency Range
    • RF Disturbance power measuring, according to CISPR 14 (EN 55014)
    • Aperture Diameter: 34.9 mm (1.37 inches)
    • Insetion Loss: 14 dB to 21 dB
    • Typically in stock with calibration and 3 Year warranty
    Request Quote/More Info
  • Quick view
    $1,597.50 $2,130.00 -25%
    • For use with one unscreened balanced pairs
    • Refers schematic circuit example in CISPR 22/32 Figure D.1/G.1
    • Intended for connection to cable category 3 and 5
    • Changeable pin-arrangements with RJ11 and RJ45
    • Can be used as CDN for IEC/EN 61000-4-6 immunity tests
    $1,597.50 $2,130.00 -25%
    Reduced price!
    Request Quote/More Info
    • 150 kHz - 230 MHz Frequency Range
    • Turnkey software for IEC 61000-4-6
    • 25 Watt Integrated Amplifier
    • Computer Based System (USB controlled)
    • Self Calibration with CDN, EM Clamp or Injection Probe
    • RF generator, amplifier and RF Voltmeter usable as independent instruments
    • Connections: EUT "Fail", EUT monitoring by external multimeter
    Reduced price!
    Request Quote/More Info
    • 100 kHz - 250 MHz Frequency Range
    • 25 W Power
    • Computer-based system (controlled by USB)
    • Self-calibration of the test system (generator and CDN)
    • RF-generator, amplifier and RF-voltmeter may as well be used as stand-alone devices
    • Connections: EUT “Fail”, EUT monitoring by external multimeter, e.g. DUT signal
    • Calibration of coupling / decoupling devices and EM clamp is performed automatically
    • Extensive additions like attenuators, calibration kits, etc. deliverable
    • Directional Coupler ( DC )
    Request Quote/More Info
    • For EMC test according to the standards IEC/EN 61000-4-16 and IEC/EN 61000-4-19
    • Output module with 5A / 250 W
    • DC, sine, triangle and square waveforms external
    • Input adds to internal signal source Windows
    • Application software via USB port
    Request Quote/More Info
    • Used for IEC/EN 61000-4-16 with LFCI4-16/19
    • DC (positive & negative), 16 2 /3 Hz, 50 Hz or 60 Hz
    • Immunity generator for short-term voltages at the frequency of the electricity supply (mains) up to 300 V
    • Output power 1800 Watts
    • Frequency Accuracy: 50 ppm
    • Output Voltage Accuracy: 5%
    • Over-heating Protection
    • Application software via USB port
    Request Quote/More Info
Showing 13 - 23 of 23 items