RF Test Generators

The EMC Shop stocks a variety of RF test generators used in conducted immunity testing and compliance. These systems have integrated signal generators, RF amplifiers and power sensors, keeping hardware minimal for tests such as IEC 61000-4-6ISO 11452-4 and MIL-STD-461 CS114.

RF Test Generators There are 21 products.

per page
Showing 1 - 12 of 21 items
    • Integrated signal generator 9 kHz to 1 GHz
    • 3 power meter inputs 9 kHz to 1 GHz
    • Integrated power amplifier module for different applications
    • Multiple EUT monitoring options
    • Optional built-in amplifier up to 75 watts (150 kHz - 230 MHz)
    • Meet IEC 61000-4-6,  IEC 61000-4-3, IEC 61000-4-20, IEC 61000-4-21 
    • Meet Mil-STD 461 CS114
    Request Quote/More Info
    • Test procedure acc. IEC 61000-4-6 Ed. 4
    • Built-in amplifier saturation and linearity check
    • Built-in power amplifier 25 to 80 watts, 10 kHz to 400 MHz
    • Built-in power meter, 9 kHz to 1 GHz
    • Built-in dual directional coupler
    • Automatic calibration via built-in power meter
    • Connection for external amplifiers up to 1 GHz
    • USB-Interface
    • Software for Windows 7, Windows 8
    Request Quote/More Info
    • Conductive immunity test system with optional CDN, EM Clamp and or Current Injection Clamp
    • Meet IEC 61000-4-6 or MIL-STD-461 CS114
    • Easy to setup and use of software
    Request Quote/More Info
    • Model CI00250A (75 Watt amplifier, 10 kHz – 250 MHz)
    • Model CI00400A (100 Watt amplifier, 10 kHz – 400 MHz)
    • Model CI00401A (150 Watt amplifier, 100 kHz – 400 MHz) 
    • EN/IEC 61000-4-6 Testing Solution
    Request Quote/More Info
    • Complete kit for ISO 11452-4 EMC Testing
    • Test methods include
      • Bulk Current Injection (BCI)
      • Tubular Wave Coupler (TWC)
    Request Quote/More Info
    • Integrated signal generator 4 kHz to 1 GHz
    • 3 power meter inputs 4 kHz to 1 GHz
    • Integrated class A power amplifier module:
      Multiple EUT monitoring options
      • 45 W, 9 kHz to 1 GHz
    • 5,7“ TFT color display
    • Internal, menu-based control software
    • Basic remote control software and report generator included
    • Optically decoupled remote control
    • Whisper mode
    Request Quote/More Info
    • 150 kHz to 230 MHz Power amplifier frequency range
    • 4 kHz to 1 GHz Integrated signal generator
    • 4 kHz to 1 GHz 3 power meter inputs
    • Integrated class A power amplifier module for different applications:
      • 35 W, 150 kHz to 230 MHz;
      • 40 W, 10 kHz to 400 MHz;
      • 45 W, 9 kHz to 1 GHz;
      • 60 W, 10 kHz to 400 MHz;
      • (>10 W, 4 kHz to 10 kHz); 80 W, 150 kHz to 230 MHz
    • Multiple EUT monitoring options
    • 5,7“ TFT color display
    • Internal, menu-based control software
    • Basic remote control software and report generator included
    • Optically decoupled remote control
    • Whisper mode
    Request Quote/More Info
    • Conductive immunity test system with optional CDN, EM Clamp and or Current Injection Clamp
    • Easily sweep from 150 kHz to 230 MHz up to 10 V/m
    • Meet IEC 61000-4-6 with easy plug and play system
    • Easy to setup and use with dedicated laptop/software
    $1,950.00
    Request Quote/More Info
    • Integrated signal generator 4 kHz to 1 GHz
    • 3 power meter inputs 4 kHz to 1 GHz
    • Integrated class A power amplifier module:
      Multiple EUT monitoring options
      • 80 W, 150 kHz to 230 MHz
    • 5,7“ TFT color display
    • Internal, menu-based control software
    • Basic remote control software and report generator included
    • Optically decoupled remote control
    • Whisper mode
    Request Quote/More Info
    • 150 kHz - 230 MHz Frequency Range
    • Turnkey software for IEC 61000-4-6
    • 25 Watt Integrated Amplifier
    • Computer Based System (USB controlled)
    • Self Calibration with CDN, EM Clamp or Injection Probe
    • RF generator, amplifier and RF Voltmeter usable as independent instruments
    • Connections: EUT "Fail", EUT monitoring by external multimeter
    Reduced price!
    Request Quote/More Info
    • Monthly Rental - Ships Immediately
    • CDN, BCI Probe or EM Clamp Required to complete test setup
    • Meet RF & Conducted Immunity Compliance Standards:
      • EN/IEC 61000-4-6
      • MIL-STD461 CS114
      • RTCA/DO160 Section 20
      • ISO 11452 part 4 BCI
      • ISO 11452 part 5 Stripline
      • IEC 60601-1-2
      • EN 61000-6-1/EN 61000-6-2
      • Various Automotive Manufacturer's Specifications
    Request Quote/More Info
    • 100 kHz - 250 MHz Frequency Range
    • 25 W Power
    • Computer-based system (controlled by USB)
    • Self-calibration of the test system (generator and CDN)
    • RF-generator, amplifier and RF-voltmeter may as well be used as stand-alone devices
    • Connections: EUT “Fail”, EUT monitoring by external multimeter, e.g. DUT signal
    • Calibration of coupling / decoupling devices and EM clamp is performed automatically
    • Extensive additions like attenuators, calibration kits, etc. deliverable
    • Directional Coupler ( DC )
    Request Quote/More Info
Showing 1 - 12 of 21 items