EN/IEC 61000-4-12

(Showing 8 of 8)
  • 3ctest

    SKU: sku-595

    3ctest RWS 600 Ring Wave Simulator up to 6.0 KV for IEC 61000-4-12

    Weight: Approx. 35Kg
    Dimensions: 19 inch/6U
    Display Interface: 5.7 inch TFT touch screen
    General Data: Technical Details
    Impedance: 12ohm, 30ohm automatic switch
    Max input power: 200W
    Phase synchronization: 0°-360°, 1° step or random
    Polarity: Positive. negative, alternating
    Pulse current (short circuit): 500A ± 10% at 12Ω; 200A ± 10% at 30Ω
    Pulse voltage (open circuit): 0.25 kV–6.0kV ± 10%
    Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
    Test duration: 1s-99s
  • Haefely

    SKU: sku-544

    Haefely PIM 110 Ring Wave Immunity System for IEC 61000-4-12

    Weight: 44 lbs (29 kg net weight)
    Dimensions: 45 x 17 x 57 cm (W x H x D)
    General Data: Technical Details
    Impedance: 12, 30 & 200 Ohms
    Phase synchronization: 1° steps ±1° @50Hz
    Polarity: Positive. negative, alternating
    Pulse repetition: 12 per minute
    Pulse voltage (open circuit): 0.20 – 7.8kV ±10%
    Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
    Test duration: 5 seconds
    $995.00 - $1,795.00
  • Haefely

    SKU: sku-526

    Used Haefely PIM 150 100 kHz & 1 MHz Oscillating Wave Surge Generator

    Burst duration: 2 seconds to continuous
    Burst frequency: 100kHz & 1MHz
    Coupling: Single & Multiple Path
    Mains & EUT Connections: HV connector & CDN
    Polarity: Positive, Negative & Alternating
    Pulse current (short circuit): 16A ac/dc per path
    Pulse repetition: 40 Hz & 400Hz
    Pulse voltage (open circuit): 480Vac (phase - phase) / 110Vdc
    Rise time: 75ns
    Source Impedance: 200 ohms
    Standards Met: IEC 61000-4-12 Power & Data lines;  ANSI C37.90.1-2002 Power lines;  IEC 60255-22-1 Measuring relays and protection equipment; IEEE 1613 Substation Equipment
    Test Voltage: 0.25 – 3.3kV
  • Thermo Keytek

    SKU: sku-321

    Thermo Keytek ECAT Transient Generator System

    Pulse current (short circuit): Selectable at 200A max. or 500A max., when the open-circuit voltage is set to 6.0kV.
    Pulse repetition: 1 shot/9 seconds
    Pulse voltage (open circuit): 200V - 6.6kV ± 10%
    Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
    Standards Met: ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864
  • Teseq

    SKU: sku-182

    Rent Teseq NSG 3060 for Surge, EFT/Burst, Dips/Interrupts, and Ring Wave up to 6.6 kV

    1 review

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
    Standards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 264 Volts
    Max EUT AC Current (w/ Built in CDN): 16 Amps
    Max EUT DC Voltage (w/ Built in CDN): 220 Volts
    Max EUT DC Current (w/ Built in CDN): 10 Amps
    EFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kA
    Combination/Wave Surge Output Capability: ±200 V to 4.4 kV (in 1 V steps)
    External Coupling: Data Lines (EFT & Surge), 3PH EUT
    Coupling: ANSI / IEC / external
    Coupling-2: ANSI / IEC / external
    Dips, Interrupts & Variations: From EUT voltage input to 0 V, 0%
    Impedance: 12/30/200 Ω
    Phase synchronization: asynchronous, synchronous 0 to 359º (in 1º steps)
    Phase synchronization-2: asynchronous, synchronous 0 to 359º (in 1º steps)
    Phase synchronization-3: asynchronous, synchronous 0 to 359º (in 1º steps)
    Polarity: positive / negative / alternate
    Polarity-2: positive / negative / alternate
    Pulse current (short circuit): ±16.6 to ±550 A, ±10%; ±6.6 to ±220 A, ±10%; ±1 to ±33 A, ±10%
    Pulse repetition: 10* s, up to 600 s (in 1 s steps) * see datasheet for derating info
    Pulse voltage (open circuit): ± 200 V to 6.6 kV (in 1 V steps)
    Repetition time: 40 μs to 35 min, 1 to 99’999 cycles
    Test duration: 1 s to 1000 h
    Test duration-2: 1 s to 70’000 min, 1 to 99’999 events, continuous
    Test duration-3: 1 to 9999 pulses, continuous
    Burst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4
    Burst frequency: 100 Hz to 1000 kHz
    Burst time: 1 μs to 1999 s, single pulse, continuous
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling-3: ANSI / IEC / external
    Dips, Interrupts & Variations-2: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Event time: 20 µs to 1999 s, 1 to 300 cycles or 1 to 3’000 1/10 cycles
    Impedance-2: 2/12 Ω
    Phase synchronization-4: asynchronous, synchronous 0 to 359º (in 1º steps)
    Polarity-3: positive / negative / alternate
    Pulse amplitude: ±200 V to 4.8 kV (in 1 V steps) - open circuit; ±100 V to 2.4 kV (50 Ω matching system)
    Pulse current (short circuit)-2: ±100 A to 3.3 kA
    Pulse repetition-2: 10* s, up to 600 s (in 1 s steps) * see datasheet for derating info
    Pulse voltage (open circuit)-2: ±200 V to 6.6 kV (in 1 V steps)
    Repetition time-2: 1 ms to 4200 s (70 min)
    Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
    Switching times: 1 to 5 μs (100 Ω load)
    Test duration-4: 1 to 9999 pulses, continuous
    Uvar with optional variac: depending on model (VAR 3005)
    Uvar with step transformer: 0, 40, 70, 80% (INA 650x)
    Typically In Stock

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.