Conducted Susceptibility, Bulk Cable Injection (BCI)
The MIL-STD-461 CS114 requirement is applicable from 10 kHz to 200 MHz for all interconnecting cables, including power cables.
The MIL-STD-461 CS114 test procedure is used to verify the ability of the EUT to withstand RF signals coupled onto EUT associated cabling.
The test equipment shall be as follows:
a. Measurement receivers
b. Current injection probes (maximum and minimum insertion loss shown on Figure CS114-2)
c. Current probes
d. Calibration fixture: coaxial transmission line with 50 ohm characteristic impedance, coaxial connections on both ends, and space for an injection probe around the center conductor.
e. Directional couplers
f. Signal generators
g. Plotter h. Attenuators, 50 ohm
i. Coaxial loads, 50 ohm
j. Power amplifiers
k. LISN
The EMC Shop offers turn key solutions to complete conductred susceptibility tests required per MIL-STD-461 CS114.
Get Application Support, Pricing, Lead Time and More: Contact Form
To Purchase Pearson 8700i
To Rent Pearson 8705C