Injecting low level RF signals and high frequency current into wires and cable bundles are a common requirement in Mil-STD-461RTCA/DO-160 and EN/IEC 61000-4-6. Bulk current injection probes are available in two styles, a window style for passing wires and cables through and a clamping style BCI probe for hard to access cable bundles or more in...

Injecting low level RF signals and high frequency current into wires and cable bundles are a common requirement in Mil-STD-461RTCA/DO-160 and EN/IEC 61000-4-6. Bulk current injection probes are available in two styles, a window style for passing wires and cables through and a clamping style BCI probe for hard to access cable bundles or more intricate systems.

Get Application Support, Pricing, Lead Time and More: Contact Form

More

Bulk Current Injection (BCI) Probes There are 18 products.

per page
Showing 1 - 12 of 18 items
    • Frequency Range: 10 kHz to 230 MHz
    • Max Input Power: 125 Watts
    • Insertion Loss: <8 dB between 150 kHz - 100 MHz
    • Aperture: 40 mm (1.57 inches)
    • Ideal for IEC 61000-4-6 BCI Testing
    $395.00
    Typically In Stock
    Request Quote/More Info
    • MIL-STD-461 CS114, CS115, CS116
    • Maximum input power 100W for 60 minutes 
    • Case temperature < 50°C 
    • 10 kHz to 400 MHz 
    $4,475.00
    Typically In Stock
    Request Quote/More Info
    • In Stock, Calibrated and Ready to Ship
    • Prices are on a Per Month Basis
    • Broad High Frequency Response: 300 kHz - 1 GHz
    • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
    • Measures currents on 50 Hz, 60 Hz and 400 Hz power lines
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe
    $195.00
    Typically In Stock
    Request Quote/More Info
    • Wide frequency range 10 kHz - 400 MHz
    • High power handling (up to 1 kW)
    • Ideal for automotive BCI testing e.g. ISO 11452-4, RTCA/DO-160 section 20, MIL-STD-461 and manufacture‘s requirements
    • Meets IEC/EN 61000-4-6
    • Replacement for CIP 36A & 37A as specified in Defence Standard 59-41
    $899.00
    Typically In Stock
    Request Quote/More Info
    • 7 dB attenuation between 100 kHz and 230 MHz when measured into a 50 ohms fixture
    • Perform IEC 1000-4-6 testing with 20 watts or less of RF power
    • Usable up to 200 watts
    • Accommodates EUT cables up to 40 mm in diameter
    4-6 Weeks
    Request Quote/More Info
    • Broad Frequency Range of 10 KHz to 100 MHz
    • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 8 to 30 dB
    • Max Input Power: 100 Watts
    • Connector: N-type, Female
    • Aperture: 1.5" (38mm)
    • Diameter: 4.25" (108mm)
    • Weight: 4.2 lbs (1.9 kg)
    Typically In Stock
    Request Quote/More Info
    • Frequency Range: 10 kHz to 175 MHz
    • Max Input Power: 100 Watts (125 Watts Peak ~30 minutes)
    • Insertion Loss: <15 dB between 2 and 150 MHz
    • Aperture: 40 mm (1.57 inches)
    Call for Availability
    Request Quote/More Info
    • Frequency range 2 MHz to 500 MHz
    • Maximum input power 200 watts (see note)
    • Maximum input current 50 Amperes
    • Maximum time at full power 30 minutes

    Typical Lead Time 4 - 6 Weeks
    Request Quote/More Info
    • Broad High Frequency Response: 10 kHz - 100 MHz
    • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
    • Measures currents on 50 Hz, 60 Hz and 400 Hz power lines
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 13 to 33 dB
    • Max Input Power: 100 Watts CS
    $1,750.00
    Typically In Stock
    Request Quote/More Info
    • Broad Frequency Range of 1 MHz - 500 MHz
    • Measures currents on 50 Hz, 60 Hz and 400 Hz powerlines
    • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 4 to 16 dB
    • Transfer Impedance: 16 to 31 dBW
    • Max Input Power: 200 Watts
    Typically In Stock
    Request Quote/More Info
    • Broad High Frequency Response: 5 MHz - 1 GHz
    • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
    • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 5 to 30 dB
    • Max Input Power: 50 Watts
    • Mas Current: 30 Amps
    Typically In Stock
    Request Quote/More Info
    • 10 KHz to 100 MHz Frequency Range
    • Suitable for CISPR 16-1-2, IEC 61000-4-6
    • Individual calibration
    • Three-year warranty
    Typically In Stock
    Request Quote/More Info
Showing 1 - 12 of 18 items