ISO 11452-4 Current Injection Probes

The EMC Shop speciailizes in automotive radiated and conducted immunity test equipment systems. Rent, buy or lease ISO 11452-4 Current Injection Probes. 

ISO 11452-4 Current Injection Probes There are 9 products.

Showing 1 - 9 of 9 items
    • Wide frequency range 10 kHz - 400 MHz
    • High power handling (up to 1 kW)
    • Ideal for automotive BCI testing e.g. ISO 11452-4, RTCA/DO-160 section 20, MIL-STD-461 and manufacture‘s requirements
    • Meets IEC/EN 61000-4-6
    • Replacement for CIP 36A & 37A as specified in Defence Standard 59-41
    $899.00
    Request Quote/More Info
    • Broad High Frequency Response: 1 MHz - 400 MHz
    • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
    • Measures currents on 50 Hz, 60 Hz and 400 Hz power lines
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 4 to 22 dB
    • Max Input Power: 100 Watts CS
    Request Quote/More Info
    • Frequency Range: 10 kHz to 175 MHz
    • Max Input Power: 100 Watts (125 Watts Peak ~30 minutes)
    • Insertion Loss: <15 dB between 2 and 150 MHz
    • Aperture: 40 mm (1.57 inches)
    Request Quote/More Info
    • MIL-STD-461 CS114, CS115, CS116
    • Maximum input power 100W for 60 minutes 
    • Case temperature < 50°C 
    • 10 kHz to 400 MHz 

    To Rent Pearson 8700i

    $4,475.00
    Request Quote/More Info
    • Rent the Teseq CIP 9136A BCI Probe
    • Wide frequency range 10 kHz - 400 MHz
    • High power handling (up to 1 kW)
    • Ideal for automotive BCI testing e.g. ISO 11452-4, RTCA/DO-160 section 20, MIL-STD-461 and manufacture‘s requirements
    • Meets IEC/EN 61000-4-6
    • Replacement for CIP 36A & 37A as specified in Defence Standard 59-41
    $4,995.00
    Request Quote/More Info
    • Frequency Range: 10 kHz to 230 MHz
    • Max Input Power: 125 Watts
    • Insertion Loss: <8 dB between 150 kHz - 100 MHz
    • Aperture: 40 mm (1.57 inches)
    • Ideal for IEC 61000-4-6 BCI Testing
    $395.00
    Request Quote/More Info
    • Frequency: 10 kHz – 400 MHz
    • Input Power rating: 100 watts
    • Less than 9 dB insertion loss between 10 kHz – 400 MHz
    • Ideal for ISO 11452-4, MIL-STD-461 CS 114
    Request Quote/More Info
    • MIL-STD-461 CS114, CS115, CS116
    • Maximum input power 100W for 60 minutes
    • Case temperature < 50°C
    • 10 kHz to 400 MHz
    • Ratio 1:1
    • Weight 6 lb (2.7 kg
    • Hole Diameter 2.0 inches [50.8 mm]
    • Width 5.75 inches [147 mm]
    • Height 5.0 inches [127 mm]
    • Thickness 1.63 inches [41 mm])
    • Use with calibration fixture F-3

    To Purchase Pearson 8700i

    $395.00
    Request Quote/More Info
    • Frequency Range 10 kHz to 400 MHz
    • Includes:
      • Pearson 8700i Current Injection Probe
      • Pearson 8705 Current Monitor
      • Pearson F-3 Calibration Jig
    • MIL-STD-461 CS114, CS115, CS116
    • DO-160 Section 21, rf CE (8705C)
    • AIAA S-121 Radio Frequency CS
    • NASA GSFC EMI Specs CE03, Bulk current emission
    • Automotive Chrysler Radio Frequency CE
    • John Deere Radio Frequency CE
    • BMW Radio Frequency CE
    • IEC / EN 61000-4-6
    • TR-102323 Radio Frequency CS
    Request Quote/More Info
Showing 1 - 9 of 9 items