Coupling Decoupling Networks (CDNs) Categories
Coupling Decoupling Networks (CDNs)
-
Com-Power CDN-M525E 5-Line Coupling Decoupling Network for Unscreened Power Lines
SKU: 10475
Current Rating: 25 Amps AC / 17 Amps DC (Max)Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)Frequency Range: 150 kHz to 230 MHzMains & EUT Connections: 4 mm shrouded banana socketsRF Connector: 50 Ω BNC (Female)$589.00 - $3,275.00In Stock -
$500.00In Stock
-
3cTest SEPN 61000T Surge/EFT Coupling Network for 3 Phase/100Amp/690V DUT
SKU: 30072
EFT/Burst Coupling Capacitor: 33nFDecoupling Inductance:: 150uHSurge Coupling Capacitor: 9/18uFCommon-mode Resistor: 0/10 ΩDecoupling Inductance: 1.5mHInquire for Availability -
Haefely FP-COMB 32 Automatic 3-Phase Coupler for AXOS System
SKU: sku-786
Burst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Pulse amplitude: 5 kVVoltage: 7 kVCompatible Impulse Generators: Haefely AXOS5, Haefely AXOS8Typically in Stock -
Teseq CDN 3425 Burst/EFT Coupling Clamp
SKU: sku-1065
Application/Test Type: Electrical Fast Transients on Data Lines (EFT Burst)Compatible Impulse Generators: Any EFT/Burst Generators (custom HV cable may be required)Standards Met: IEC / EN 61000-4-4Inquire for Availability -
Teseq CDN 3083-Burst 1000 Volt, 100-200 Amp Coupler for EFT/Burst
SKU: sku-221
Weight: 11 kg (24 lbs)Application/Test Type: EFT/Burst immunity testing of equipment requiring large currents, specially designed for heavy industry, smart grid and electro vehicle applications.Current Rating: 100 Amp or 200 Amp continous depending on modelCompatible Impulse Generators: Any EFT/Burst Generators (custom HV cable may be required)Mains & EUT Connections: SHV; Screw terminals, rated for 200 A$395.00 - $495.00In Stock -
AR IT2002 Remote Switchable Impedance Transformer
SKU: 11751
Input Impedance: 50 OhmsOutput Impedance: 50, 100, 200, 450, 900, 1800 OhmsFrequency Range: 100 kHz - 3 MHzRF Connectors: Input N, Output High Voltage Terminals$3,500.001 Left -
3ctest EFTN CDN for Burst, Three Phase 5-wire, AC 380V, 32A, Max 440V
SKU: sku-564
Weight: approx. 50KgBurst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Burst frequency: 0.1kHz–1000kHzDimensions: 19 inch/6UExternal: External control: 25Pin D-BusInquire for Availability -
Haefely IP4A Coupling Clamp for EFT/Burst Immunity on Data Lines
SKU: 2551
Application/Test Type: Electrical Fast Transients on Data Lines (EFT Burst)Max. Cable Diameter: 40 mm (at least 1m length)Standards Met: IEC 61000-4-4Test Voltage: up to 8 kV$195.00 - $1,975.00Typically In Stock -
EMC Partner CDN-KIT1000 ED3
SKU: 35425
Standard: IEC 61000-4-5Application: surge on 2 unsymmetrical linesTest level surge: max. 6 kVEUT voltage per line: max. 200 V DC or 240 V peakEUT current per line: max. 4 A cont. or 5 A for 5 min.Typically In Stock -
Haefely PCD 130 3 Phase Coupling/Decoupling Network for PSURGE 8000
SKU: sku-444
Weight: 69 kg (net weight)Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling: 3 Phase - 32 Amps, 690 VACDimensions: 45 x 50 x 57 cm (W x H x D)General Data: Technical DetailsIn Stock -
3ctest SPN Series CDN's for Lightning Surge, Single Phase 3-wire, Three Phase 5-wire
SKU: sku-563
Weight: approx. 50KgDimensions: 19 inch/6UImpedance: 2 ohm (output)Polarity: +/-/alternativeVoltage: 0.2kV–6kV,±10%Inquire for Availability