Industries and Certification Standards

Automotive

Military & Aerospace

MIL-STD-461 CS101
MIL-STD-461 CS114
DO-160 Section 16
DO-160 Section 18
DO-160 Section 20

Get Started

Rentals, Prices, Abailability of EM Test equipment.

Value is required
SENT!
Show 12 24 36 48

EM Test (Ametek CTS) Categories

EM Test (Ametek CTS) Test Equipment, Systems & Solutions

  • Monthly Rental EM Test CWS 500N Continuous Wave Simulator for IEC 61000-4-6

    SKU: sku-921

    Weight: 17 kg (37.5 Pounds)
    Application/Test Type: Create and output RF currents as well as measure input for CDN and clamp calibration as well as current monitor for clamp applications
    Dimensions: 19"/3 HU
    Frequency Range: Sinus (CW) 100kHz to 300MHz Frequency bands 100kHz to 9.999MHz 10MHz to 99.99MHz 100MHz to 300MHz
    Impedance: 50 Ohms
    Input: 115 V to 230 V +10/-15 %, 50/60 Hz (380 Watts Max)
    Maximum Continuous Power: 80W (nominal)
    Standards Met: IEC 61000-4-6
    Test Routines: Quick Start, User Test Routines, Standards Test Routines (IEC/EN 61000-4-6), Cal Procedure, Service
    Voltage Rating: 1 V to 30 Volts Max
  • EM Test LD 200N Load Dump Generator for ISO 16750-2

    SKU: sku-817

    Output: +/- output Safety laboratory connectors Coupling To the battery +lineDecoupling Via diodeDUT supply Max. 80V/30A
    Freestyle Mode Micropulses: Rise time 1us 10us - 90us with 10us steps 100us - 900us with 100us steps 1ms - 10ms with 1ms steps Pulse duration 10ms - 1,200ms Int. resistor 0.5ohm - 38ohm, in steps of 0.1ohm
    Test Standards: ISO 7637-2 Pulse 5b for 12V and 24V, ISO/WD 16750 Pulse 5b, and much more
    Test Routines: Quick Start, User Defines Routines, Standards Test Routines Service
    $1,690.00
    Typically In Stock
  • Rent EM Test TSS 500M2F Telecom Surge Simulator for FCC Part 68

    SKU: sku-776

    Weight: approx. 35kg
    Application/Test Type: Test levels as per FCC part 68
    Coupling: Telecom ports: Tip to Ground, Ring to Ground, Tip and Ring to Ground Power ports 250V/16A: L toN, L to PE, N to PE , L+N to PE
    Dimensions: 19“ / 6HU,
    Output Current: 64A – 1,000A (power line) 20 – 200A per wire (surge A)
    Outputs: 4 mm banana socket
    Polarity: pos / neg / alternate
    Rise time: Less than 2 us
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test Voltage: 160V – 2,500V ± 10% (power line) 160V – 1,500V ± 10% (surge A)
    Trigger of bursts: Automatic pulse release
  • EM Test PFS 503N32 Power Fail Simulator, 3-phase 3x480V AC (p-p) max. 32A

    SKU: sku-549

    Weight: app. 28kg;
    Current Rating: Max. 32A
    Dimensions: 19"/6 HU
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Frequency: 50Hz/60Hz, Single phase application
    Output: 3-phase application L1, L2, L3, N and PE on the rear panel. 1-phase application L, N and PE on the front panel
    Peak current: Better than 500A
    Repetition rate: 0.01s to 9,999s
    Rise time: Between 1us and 5us for abrupt changes, generator loaded with resistive load
    Supply Voltage: 115V/230V; +10/-15%
    Test Voltage: 3x480V AC resp. 3x690V AC (L-L) 277V AC resp. 400V AC 360V DC resp. 600V DC (L-N)
    Trigger of bursts: Automatic
  • EM Test OCS 500N6F Simulator for Fast/Slow Damped Oscillatory Waves and Ringwave

    SKU: sku-413

    Burst duration: 50 ms ±20%, at 3 MHz 15 ms ±20%, at 10 MHz 5 ms ±20%, at 30 MHz
    Damping Rate: Peak 5 to be more than 50% of peak 1 value Peak 10 to be less than 50% of peak 1 value
    Oscillation Frequency: 3 MHz, 10 MHz and 30 MHz, ±10%
    Polarity: Positive, negative
    Rise Time: 75ns ± 20%
    Rise Time-2: 5 ns ±30%
    Source Impedance: 50 ohm ±20%
    Voltage: Voltage (o.c.) at HV output 450 V - 4,400 V ±10%
    Weight: 32 kg (1-phase) 50 kg (3-phase)
    Slow Damped Oscillatory Waves: As Per EN/IEC 61000-4-18
    Burst Duration: At least 2s
    Damping Rate-2: Peak 5 to be more than 50% of peak 1 value Peak 10 to be less than 50% of peak 1 value
    Dimensions: 19" / 9 HU, approx. 19" / 9 HU, approx.
    Fast Damped Oscillatory Waves: As Per EN/IEC 61000-4-18
    Frequency: 100 kHz ± 10%
    General Data: Technical Details
    Impedance: 12ohm and 30ohm ± 20%
    Oscillation Frequency-2: 100kHz and 1MHz ± 10%
    Peak current: Max. 500A @ 12ohm or Max. 200A @ 30ohm internally;
    Polarity-2: Positive, negative
    Pulse repetition: 1 to 60 transients per minute
    Repetition Rate: Max. 5,000 /s ±10%
    Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
    Rise time: 0.5 us ± 30%
    Source impedance: 200ohm ± 20%
    Spike frequency: 100kHz ± 10%
    Supply Voltage: 115/230V +10/-15%
    Test Voltage: 250 V - 6,000 V ± 10%
    Voltage-2: Voltage (o.c.) at HV output 250 V - 3,000 V ± 10% Voltage (o.c) at line output 250 V - 2,500 V ± 10%
  • EM Test CWS 500N1 Continuous Wave Simulator for IEC 61000-4-6

    SKU: sku-410

    Weight: 17 kg (37.5 Pounds)
    Application/Test Type: Create and output RF currents as well as measure input for CDN and clamp calibration as well as current monitor for clamp applications
    Dimensions: 19"/3 HU
    Frequency Range: Sinus (CW) 100kHz to 300MHz Frequency bands 100kHz to 9.999MHz 10MHz to 99.99MHz 100MHz to 300MHz
    Impedance: 50 Ohms
    Input: 115 V to 230 V +10/-15 %, 50/60 Hz (380 Watts Max)
    Maximum Continuous Power: 80W (nominal)
    Standards Met: IEC 61000-4-6
    Test Routines: Quick Start, User Test Routines, Standards Test Routines (IEC/EN 61000-4-6), Cal Procedure, Service
    Voltage Rating: 1 V to 30 Volts Max
  • EM Test TSS 500N10 Telecom Surge Generator ITU-T for Enhanced Level Testing up to 10 kV

    SKU: sku-403

    Weight: approx. 37.1 kg (81.8 lbs.)
    AC Power Adapter: Supply voltage 115/230 V +10/-15%
    Dimensions: 19"/9 HU, 420 mm x 448 mm x 500 mm
    Energy Storage Capacitor: 1 uF (Pulse 1.2/50 us) 20 uF (Pulse 10/700 μs) 20 uF (Surge Pulse B)
    Front Time: 1 us ± 30% (Pulse 1.2/50 us) 10 us ± 30% (Pulse 10/700 μs) 9 us ± 30% (Surge Pulse B)
    Pulse Duration: 50 us ± 20% (Pulse 1.2/50 us) 700 us ± 20% (Pulse 10/700 us) 720 us ± 20% (Surge Pulse B)
    Standards Met: IEC 61000-4-5 ITU-T K.17 ITU-T K.20 ITU-T K.21 ITU-T K.28 ITU-T K.45 (and more)
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test Voltage: 500 V - 10,000 V ± 10%