The EM TEST modular multifunctional test generators are the ideal starting point to set up an EMC test facility. Most versatile to meet many requirements but also most ecomomic in terms of cost they are designed for fully compliant conducted immunity testing. The EMC Shop stocks a variety of configurations to help you meet your testing needs, now.

  • EM Test

    SKU: sku-2169

    EM Test Surge, EFT, PQF, Ring Wave Immunity System for 3 Phase, 100 Amp EUT

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts, Ring Wave
    Standards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-12 IEC/EN 61000-4-29
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 480 Volts
    Max EUT AC Current (w/ Built in CDN): 100 Amps (Per Phase)
    Max EUT DC Voltage (w/ Built in CDN): 1000 Volts
    Max EUT DC Current (w/ Built in CDN): 100 Amps
    Peak inrush current capability: 500 Amps
    EFT/Burst Pulse Output Capability: 5.5 kV
    Combination/Wave Surge Output Capability: 6.6 kV
    External Coupling: Data Lines (EFT & Surge)
    Dips & Interrupts: 40%, 70%, 80%; Interrupts - 0% (short and open)
    Ring Wave: 100 kHz, 6 kV
    RENTAL ONLY
  • EM Test

    SKU: sku-1195

    Complete IEC/EN Test Rack for CE Marking and Conducted Immunity Certification

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
    Standards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 264 Volts
    Max EUT AC Current (w/ Built in CDN): 16 Amps
    Max EUT DC Voltage (w/ Built in CDN): 220 Volts
    Max EUT DC Current (w/ Built in CDN): 10 Amps
    Peak inrush current capability: 500 A (at 230 V)
    EFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kA
    Combination/Wave Surge Output Capability: ±200 V to 4.4 kV (in 1 V steps)
    External Coupling: Data Lines (EFT & Surge), 3PH EUT
  • EM Test

    SKU: sku-1045

    EM Test NX7 Multifunctional Test Generator For Transients

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts, Ring Wave
    Standards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-12 IEC/EN 61000-4-29, ANSI/IEEE C62.4
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 300 Volts
    Max EUT AC Current (w/ Built in CDN): 16 Amps
    Max EUT DC Voltage (w/ Built in CDN): 300 Volts
    Max EUT DC Current (w/ Built in CDN): 16 Amps
    EFT/Burst Pulse Output Capability: 5.5 kV
    Combination/Wave Surge Output Capability: 7 kV
    Dips & Interrupts: 0, 40, 70, 80%
    Ring Wave: 7 kV / 100 kHz
    External Coupling: 3PH up to 200 Amps / Data Lines
    INQUIRE
  • EM Test

    SKU: sku-547

    EM Test NX5 Compact EMC Generator for EFT/Burst, Surge & Power Fail up to 5.5 kV

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
    Max EUT Voltage (w/ Built in CDN): 300 Volts
    Max EUT Current (w/ Built in CDN): 16 Amps
    Peak inrush current capability: 500 Amps (up to 2.5 kA)
    EFT/Burst Pulse Output Capability: 5.5 kV
    Combination/Wave Surge Output Capability: 5 kV
    External Coupling: Data Lines (EFT & Surge), 3PH EUT
    Dips, Interrupts & Variations: 16 Hz - 500 Hz and DC
    INQUIRE
  • EM Test

    SKU: sku-241

    EM Test UCS500N7 Multifunctional Transient Immunity Simulator

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
    Standards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 264 Volts
    Max EUT AC Current (w/ Built in CDN): 16 Amps
    Max EUT DC Voltage (w/ Built in CDN): 220 Volts
    Max EUT DC Current (w/ Built in CDN): 10 Amps
    Peak inrush current capability: 500 A (at 230 V)
    EFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kA
    Combination/Wave Surge Output Capability: ±200 V to 4.4 kV (in 1 V steps)
    External Coupling: Data Lines (EFT & Surge), 3PH EUT
    Coupling: L, N, PE; all combinations
    Coupling-2: L, N, PE; line to line and line(s) to ground
    Dips, Interrupts & Variations: As per IEC/EN 61000-4-11, IEC/EN 61000-4-29 and IEC/EN 61000-6-1, -6-2
    Impedance: 12 ohm and 30 ohm
    Phase synchronization: 0° - 360°, resolution 1° (16 - 500Hz)
    Phase synchronization-2: 0° - 360°, resolution 1° (16 - 500Hz)
    Phase synchronization-3: 0° - 360°, resolution 1°
    Polarity: positive / negative
    Polarity-2: Positive, negative
    Polarity-3: Positive, negative, alternating
    Pulse current (short circuit): Wave Shape
    Pulse repetition: Automatic, manual, external
    Pulse voltage (open circuit): 250 V - 6,000 V ± 10%
    Repetition time: 10ms - 9,999s
    Test duration: 0:01min - 99:59min
    Test duration-2: max. 1 Hz (1 s - 999 s)
    Weight: 25 kg's (55 Lbs)
    Application/Test Type: CE Marking - Cover transient and power fail requirements according to international standards for immunity tests
    Burst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4
    Burst frequency: 0.1 kHz - 1,000 kHz
    Burst time: 0.10ms - 999ms
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Counter: 1 - 30,000 or endless, selectable
    Coupling-3: As per IEC 61000-4-5: Line to line with 2 ohm, Line(s) to ground with 12 ohm; As per ANSI/IEEE C62.41: Line to line with 2ohm, Line(s) to ground with 2ohm
    Dimensions: 19", 3HU
    Dips, Interrupts & Variations-2: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Energy Storage Capacitor: 20 uF
    Event time: 20us - 9,999s
    Event Trigger: Automatic, manual, external
    Front Time: As per ITU and ETSI recommendations: 10 us ± 30%; As per FCC part 68, Pulse B: 9 us ± 30%; As per IEC 61000-4-5: 5 us ± 30%
    Impedance-2: 2 Ohm / 12 Ohm
    Output Current: 6 A - 175 A (short circuit) at 25 Ohm Output
    Outputs: For 2-wire T1/T2 with 25 ohm each & For 4-wire T1/T2/T3/T4 with 25 ohm each
    Peak inrush current capability: 500 Amps
    Phase synchronization-4: 0° - 360°, resolution 1°
    Polarity-4: positive / negative / alternating
    Pulse amplitude: 200V - 5,500V ± 10%; 100V - 2,750V ± 10% into 50ohm
    Pulse current (short circuit)-2: Max. 3,500 A ± 10%
    Pulse Duration: As per ITU and ETSI recommendations: 700 us ± 20%; As per FCC part 68, Pulse B: 720 us ± 20%; As per IEC 61000-4-5: 320 us ± 20%
    Pulse repetition-2: max. 0.5Hz (2s - 999s)
    Pulse voltage (open circuit)-2: 250 V - 7,000 V ± 10%
    Repetition Rate: Max. 0.33 Hz (3 s - 999 s)
    Repetition time-2: 10ms - 9,999ms
    Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
    Standards Met: ANSI/IEEE C62.41; IEC 61000-4-11; IEC 61000-4-12; IEC 61000-4-29; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-8; IEC 61000-4-9; EN 61000-6-1; EN 61000-6-2; ITU-T K.XX; UL 1741
    Switching times: Under 5us into a 100ohm resistive load
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test duration-3: 1 - 30,000 or endless, selectable
    Test Voltage: 250 V - 7,000 V ± 10%
    Uvar with optional variac: N/A
    Uvar with step transformer: 300V AC
  • EM Test

    SKU: sku-240

    EM Test UCS 500N5 Multifunctional Generator for EFT/Burst, Surge & Power Fail up to 5.5kV

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
    Standards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 264 Volts
    Max EUT AC Current (w/ Built in CDN): 16 Amps
    Max EUT DC Voltage (w/ Built in CDN): 220 Volts
    Max EUT DC Current (w/ Built in CDN): 10 Amps
    Peak inrush current capability: 500 A (at 230 V)
    EFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kA
    Combination/Wave Surge Output Capability: ±200 V to 4.4 kV (in 1 V steps)
    External Coupling: Data Lines (EFT & Surge), 3PH EUT
    Coupling: L, N, PE; all combinations
    Dips, Interrupts & Variations: As per IEC/EN 61000-4-11, IEC/EN 61000-4-29 and IEC/EN 61000-6-1, -6-2
    Phase synchronization: 0° - 360°, resolution 1° (16 - 500Hz)
    Phase synchronization-2: 0° - 360°, resolution 1° (16 - 500Hz)
    Polarity: positive / negative
    Repetition time: 10ms - 9,999s
    Test duration: 0:01min - 99:59min
    Weight: 25 kg's (55 Lbs)
    Application/Test Type: CE Marking - Cover transient and power fail requirements according to international standards for immunity tests
    Burst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4
    Burst frequency: 0.1 kHz - 1,000 kHz
    Burst time: 0.10ms - 999ms
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling-2: Line to line; Line(s) to ground
    Dimensions: 19", 3HU
    Dips, Interrupts & Variations-2: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Event time: 20us - 9,999s
    Impedance: 2 Ohm
    Peak inrush current capability: 500 Amps
    Phase synchronization-3: 0° - 360°, resolution 1°
    Polarity-2: positive / negative / alternating
    Pulse amplitude: 200V - 5,500V ± 10%; 100V - 2,750V ± 10% into 50ohm
    Pulse current (short circuit): Max. 2,500A ± 10%
    Pulse repetition: max. 1Hz (1s - 999s)
    Pulse voltage (open circuit): 160V - 5,000V ± 10%
    Repetition time-2: 10ms - 9,999ms
    Standards Met: FCC 97-270 (part 68); IEC 60255-22-5; IEC 61000-4-11; IEC 61000-4-29; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-8; IEC 61000-4-9; IEC 61326; IEC 61850-3
    Switching times: Under 5us into a 100ohm resistive load
    Test duration-2: 1 - 30,000 or endless, selectable
    Uvar with optional variac: N/A
    Uvar with step transformer: 300V AC + DC