Voltage Dips and Interruptions Testers Test Equipment, Systems & Solutions
-
Rent Chroma 61605 Single Phase AC Power Source
SKU: sku-2125
Weight: 71 kg/165.2 lbsCurrent rating: 120 ampsDimensions: 400 x 482 x 600 mm (15.75 x 19 x 24 in)Frequency Range: DC, 15 Hz - 1.2 kHz (.15% accuracy)Output current: 16 Amps RMS (96 Amps Peak)Output voltage: 6000 VA max, 2000 VA per phaseVoltage ranges: 150-300 Volts$1,295.00 -
EM Test PFS 500 Power Fail Simulator for EN/IEC 61000-4-11
SKU: sku-1292
Test Standards: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29Applications: Voltage dips, Voltage interruptions, Voltage variations, Inverse, EMC Precompliance Testing, Conducted ImmunityEUT Power Handling: AC up to 240V/16A$4,750.001 Unit -
-
Schloder VIS 1700 Voltage Interruption Simulator
SKU: sku-784
Communication: BNC outputs (on rear) for voltage, current and scope triggeringCoupling: BNCDips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29General Data: Technical DetailsMains & EUT Connections: 4mm banana lineOutput Current: AC max. 280 V, DC max. 3 6 0 VPeak inrush current capability: 16 AmpsPhase synchronization: at any phase position 0° - 360 °Test duration: 0.1sec - 9990sec, furthermore single event and continuous operationTest Voltage: AC max. 280 V ,DC max. 3 6 0 VApplications: EMC Precompliance Testing, Conducted ImmunityTypically In Stock -
3ctest PFS 2216SVD Single Phase Power Fail Simulator w/ Two Semiconductor Switches for High Current Protection
SKU: sku-591
Weight: 40KgCommunication: Ethernet LAN、RJ45Coupling: BNCDimensions: 19 inch/6UDips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29Frequency: 45-65HzGeneral Data: Technical DetailsInput: BNC,5V TTLMains & EUT Connections: 4mm banana lineMaximum Continuous Power: 100WOutput Current: 16A AC/DC continuous current; 20A continuous 5s 40Acontinuous 3sPeak inrush current capability: 500 AmpsPhase synchronization: 0°- 360°,1° step or randomRepetition time: 0.3-9999 cycle or 5ms-9999msRise time: 1-5us(100Ω load)Supply Voltage: 110V/220V, ±10%, 50/60HzTest duration: 50ms-50000msTest Voltage: 250V AC,300V DCTrigger: BNC,5V TTL -
3ctest PFS 2216SD Power Fail Simulator for EN/IEC 61000-4-11
SKU: sku-590
Test Standards: IEC/EN 61000-4-11, IEC/EN 61000-4-29Mains & EUT Connections: 4mm banana lineOutput Current: 16A AC/DC continuous current; 20A continuous 5s 40Acontinuous 3sPeak inrush current capability: 500 AmpsApplications: EMC Precompliance Testing, Conducted ImmunityRise time: 1-5us(100Ω load)Test duration: 50ms-50000msTest Voltage: 250V AC,300V DCTrigger: BNC,5V TTLInquire for Availability -
3ctest PFS 6030A Power Failure Simulator for Voltage Dips & Drops,60 V / 30 A
SKU: sku-588
Test voltage: Voltage drop: 1V max@30AWeight: 20 kgDimensions: 19" / 4 UOutput: DUT voltage monitoring output: BNC,10:1 coaxial terminal output DUT current monitoring output: BNC,10A:1V coaxial terminal outputPeak current: 60A duration time 500 msPulse duration: Drop duration time td 1us - 10 sRepetition rate: 100 ms - 999sSource Impedance: High resistance or low resistanceTest Voltage: 0–60 VTrigger: External trigger signal by oscilloscope, BNC,5V TTLTrigger of bursts: Automatic, manual, external -
EM Test PFS 503N32 Power Fail Simulator, 3-phase 3x480V AC (p-p) max. 32A
SKU: sku-549
Weight: app. 28kg;Current Rating: Max. 32ADimensions: 19"/6 HUDips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29Frequency: 50Hz/60Hz, Single phase applicationOutput: 3-phase application L1, L2, L3, N and PE on the rear panel. 1-phase application L, N and PE on the front panelPeak current: Better than 500ARepetition rate: 0.01s to 9,999sRise time: Between 1us and 5us for abrupt changes, generator loaded with resistive loadSupply Voltage: 115V/230V; +10/-15%Test Voltage: 3x480V AC resp. 3x690V AC (L-L) 277V AC resp. 400V AC 360V DC resp. 600V DC (L-N)Trigger of bursts: Automatic -
Haefely PLINE 1610 Voltage Failure Simulator
SKU: 10503
Test Standards: IEC/EN 61000-4-11, IEC/EN 61000-4-29Voltage Range: 0 - 264 VoltsFrequency Range: 48 to 62 HzCurrent Range: up to 16A rms continuous, 20A @ 80%, 23A @ 70%, 40A @ 40%(rms for 5s)Phase synchronization: Synchronous 0 to 360 resolution, AsynchronousTest duration: 1s to 100 hoursTrigger: Auto, Manual, External$1,275.00Typically In Stock -
Teseq INA 6501 Manual Step Transformer for AC Dips & Interruptions
SKU: sku-116
Accuracy: ±5%Input voltage UIN: 0 to 250 VAC, 50/60 HzOutput voltage UVAR: 4 steps: 0% - 40% - 70% - 80% of UINVoltage change with load: 00% output, 0 to 16 A less than 5%; 80% output, 0 to 20 A less than 5%; 70% output, 0 to 23 A less than 5%; 40% output, 0 to 40 A less than 5%$2,060.00 -
Haefely DIP 116 Automatic Dips Transformer 16 Amps 40/70/80%
SKU: HAE-DIP116
Test Standards: IEC 61000-4-11Typically In Stock -
3ctest PFS Single Phase Power Fail Simulator
SKU: sku-1108
Test Standards: IEC/EN 61000-4-11, IEC/EN 61000-4-29Applications: EMC Precompliance Testing, Conducted ImmunityEUT Power Handling: up to 260 Volts and 20 Amps (3 Phase models available)Rentals: Ship Same Day4-6 Weeks