ITU-T K

(Showing 4 of 16)

The EMC Shop carries a variety of Telecommunications Test Equipment for ITU-T K compliance.

Show 12

ITU-T K Test Equipment, Systems & Solutions

  • Haefely DEC 6 Decoupling Network for Symmetrical Data and Control Lines

    SKU: sku-409

    Weight: approx. 2 kg net
    Coupling: Decoupling elements Resistors 200 Ohm
    Dimensions: 30 x 20 x 16 cm (w x h x d)
    DUT current: Current on EUT lines max. 0.1A
    Pulse amplitude: max. 6.6kV
    Pulse Shape: 10/700us -5/320us 1.2/50us - 8/20us 100kHz ring wave
    Test Voltage: Voltage on EUT lines max. 72V DC or 50V AC,RMS (with gas arrestors as protection elements) max. 144V DC or 100V AC,RMS (with ABDs as protection elements)
    In Stock
  • 3ctest CWS 600CT Combination Wave & Telecom Surge Simulator, 1.2/50us 8/20us 10/700us 5/320us

    SKU: sku-333

    Polarity: Positive, Negative or Alternate
    Weight: Approx 15 kg (33 lbs)
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Counter: 1-999
    Coupling: Optional for external SPN series CDN's
    Dimensions: 19 inch/6u
    Frequency Range: 50/60Hz±5%
    Front Time: Voltage: 10us±20%, time to half value: 700us±20%;
    Impedance: 2 phm, Optional 12 ohm and 500 ohm
    Mains & EUT Connections: 4mm banana plug
    Output Current: Front time: 5us±20%, time to half value: 320us±20%
    Polarity-2: Positive, Negative and Alternating
    Pulse current (short circuit): 0.15 kA–3.0kA ±10% (2ohm)
    Pulse Duration: 11s-99s (shortest depends on test voltage)
    Pulse repetition: 1-999
    Pulse voltage (open circuit): 0.3kV–6.0kV ±10%
    RF Connector: BNC, 5VTTL
    Standards Met: UL 1449, ANSI C62.41, IEC 61000-4-5, EN & IEC 60255-5, GB/T 17626.5
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test duration: 6s-99s
    Test Voltage: 0.2kV–6.0kV,±10%
    Transfer Impedance: 15ohm, 40ohm (automatic switch)
    Voltage Rating: AC 110V/220V , ±10%,
  • 3ctest CWS 600T 10/700us Telecom Wave Surge Simulator for IEC 61000-4-5

    SKU: sku-330

    Weight: Approx 15 kg (33 lbs)
    Counter: 1-999
    Dimensions: 19 inch/6u
    Frequency Range: 50/60Hz±5%
    Front Time: Voltage: 10us±20%, time to half value: 700us±20%;
    Mains & EUT Connections: 4mm banana plug
    Output Current: Front time: 5us±20%, time to half value: 320us±20%
    Polarity: Positive, Negative or Alternate
    Pulse Duration: 11s-99s (shortest depends on test voltage)
    RF Connector: BNC, 5VTTL
    Standards Met: IEC 61000-4-5 and ITUETSI
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test Voltage: 0.2kV–6.0kV,±10%
    Transfer Impedance: 15ohm, 40ohm (automatic switch)
    Voltage Rating: AC 110V/220V , ±10%,