PMM 3010 EMC RF Signal Generator, 9 kHz to 1 GHz

Condition:
Used

No reviews yet Write a Review
Frequency Range:
9 kHz to 1 GHz
Frequency Resolution:
1 kHz
Frequency Accuracy:
± 10 ppm @ f > 10 MHz
Level Range:
-107 to +10 dBm
Output Impedance:
50 Ω
Connector:
N-Type (f)
Applications:
Radiated Immunity
Test Standards:
IEC 61000-4-3
Manufacturer:
PMM

 

Availability:

Typically in Stock

SKU:
30169

 


Getting Started...

Check out our Google Reviews

PMM 3010 Overview

New RF Generator PMM (Narda) PMM 3010 covering the frequency range 9 kHz 1 GHz: an optimal cost/performance component for those immunity tests not requiring higher frequencies. Like the 3 GHz model PMM 3030, it features internal AM & Pulse modulations. USB/RS232 remote control and AC/DC supply as standard; optional GPIB-IEEE488 available.

Technical Specifications
Frequency range 9 kHz - 1 GHz
Frequency resolution 1 kHz
Frequency accuracy (internal reference) ± 10 ppm @ f > 10 MHz
Level range -107 to +10 dBm -107 to +10 dBm
Level resolution 0,1 dB
Level accuracy ± 1 dB, level > -30 dBm
Output impedance 50 Ω
RF output connector Type N female
Spectral purity-harmonic 1 MHz
AM modulation, internal 2-50-400 Hz, 1 KHz; 10% to 90 %
AM modulation, external 2 Hz to 10 kHz; 10% to 90 %
Input impedance 600 Ω
Input connector BNC female
Internal pulse modulation 1 Hz: On/Off ratio @ 0 dBm > 40 dB
200 Hz: On/Off ratio @ 0 dBm > 40 dB
Remote control RS232, USB 2.0 (rear), User Port
GPIB (external adapter)
User Port RF On/Off, Start/Stop test
Display 340 x 240 pixels, 16 grey levels
Display units dBm, dBµV
Operating Temperature +10 °C to +40 °C
Power Supply DC 10 - 15 V, 2,5 A
AC/DC adapter 115 - 230 V 50/60 Hz
Plug-in battery pack (model 3030-02)
Dimensions 235 x 105 x 335 mm (WxHxD)
Weight 3.5 kg

Videos

PMM 3010 Key Considerations

Manufacturer:
PMM
Frequency Range:
9 kHz to 1 GHz
Frequency Resolution:
1 kHz
Frequency Accuracy:
± 10 ppm @ f > 10 MHz
Level Range:
-107 to +10 dBm
Output Impedance:
50 Ω
Connector:
N-Type (f)
Applications:
Radiated Immunity
Test Standards:
IEC 61000-4-3