Overview
The ISN PLT-A is made for measurements on PLT devices which use one port for mains power supply and telecommunications (PLT port). It is conform with the requirements of EN 50561-1. Included in the delivery is the Coupling Unit (CU) as given in figure 3 of the standard.
Features & Specifications of Teseq ISN PLT-A:
- Max. operating voltage: 250 VAC, 50 Hz, Mains L / N / PE
 - Max. operating current: 10 A
 - Test voltage: 1.5 kV AC, 2 s
 - Mains sockets EUT / AE: 4 mm, safety
 - RF sockets: BNC, 50 Ω
 - Frequency range: 1.6 MHz to 30 MHz
 - Common mode impedance: 25 Ω ±3 Ω
 - Phase angle: 0° ±25°
 - Differential mode impedance: 100 Ω ±10 Ω
 - Phase angle: 0° ±25°
 - Voltage division factor: 0 dB ±1 dB
 - Isolation (common mode): >55 dB
 - Insertion Loss – symmetric: <3 dB
 - LCL: >55 dB
 - Coupling Unit
 - Max. operating voltage: 250 VAC, 50 Hz, Mains L / N / PE
 - Max. operating current: 10 A
 - Mains sockets Coupling Unit: Schuko
 - Common mode decoupling attenuation *): >40 dB
 - Insertion Loss (differential mode) *): >40 dB
 
*) Parameters are only valid for a test setup with two identical AMNs like NNB 51 or NNB 52 All symmetrical parameters are only valid for a symmetrical impedance of 100 Ω
Mechanical Specifications
- Size (W x H x D) in mm: 185 x 100 x 100
 - Size of the base plate in mm: 235 x 100
 - Weight: approx. 1450 g
 - Size of the Coupling Unit (W x H x D) in mm: 95 x 63 x 85 (each box)
 - Cable length of the Coupling Unit: approx. 0.8 m
 - Weight of the Coupling Unit: approx. 260 g