            EFP6G Isotropic Electric Field Probe 100 kHz - 6 GHzSKU: sku-2190 Weight: 0.2 lb, 100 gDimensions: (LxD): 9.0x2.25 inch, 230x58 mmFrequency range: 100 kHz - 6 GHz
- 
            EFT-DLC EFT/Burst Capacitive Coupling Clamp for Data LinesSKU: 1780 Application/Test Type: Electrical Fast Transients on Data Lines (EFT Burst)Built in Accordance to: IEC 61000-4-4Coupling Length: 1 m (39.4 in)Compatible Impulse Generators: Any EFT/Burst Generators (custom HV cable may be required)RF Connector: Fischer HV Connector$195.00 - $2,495.00In Stock
- 
            EFT4-4 Fast Transient Burst GeneratorSKU: 12174 EFT/Burst Pulse Output Capability: 100 Volts to 5 kV (10V steps)Max EUT Voltage (w/ Built in CDN): 230 Volts AC (110 VDC)Max EUT Current (w/ Built in CDN): 16 Amps (8 ADC)Programmability: Burst duration, burst period, burst frequency, pulse amplitude, polarity, number of pulses per second, max number of pulses burst,Pre-programmed: Test levels 1 - 4 of the IEC/EN 61000-4-4 standardIn Stock
- 
            ELMAG20A Air Gap Electromagnet up to 2.2 TeslaSKU: 72333 Number of turns (per Coil): 2000Resistance at Room Temperature: 14 ΩMaximum Permissible Resistance During Use: 16 ΩMaximum Coil Current: 20 A 1 min, 15 A 3 min, 10A 6 min, 5 A >20 minAir Gap Between the Poles: 0...95 mm$2,450.00 - $21,950.00Lead Time: ~ 8 Weeks
- 
            EMC/RF Shielded Tent Enclosure - RFT SeriesSKU: 12035 Attenuation: 90 dB typicalFrequency Range: (150 kHz) 30 MHz - 18 GHzApplications: EMC Precompliance Testing, Radiated Emissions, Radiated ImmunityStandard Options: Lights and VentEnclosure Size: up to 10ft x 20ft 10ftMost Sizes In Stock
- 
            EMI-AK7G Antenna Kit Radiated Emissions MeasurementsSKU: 10517 Frequency Range: 20 Hz - 7 GHzApplications: EMC Precompliance Testing, Radiated Emissions, TEMPEST TestingTest Standards: FCC Part 15, MIL-STD-461, IEC 61000-6-3, IEC 61000-6-4Typically in Stock
- 
            EPT-0.8 EMC Plastic TableSKU: 666541 Dimensions: 31.4 in/0.8 m (D) x 31.4 in/0.8 m (H)Load capability: Up to 220 LbsMaterial structure: RohacellDielectric constant e at 1 MHz: 1.05Material table top (removable) with a grid of 100 mm x 100 mm (3.9x 3.9 in): Pertinax t = 2 mm (0.07 in)Inquire for Availability
- 
            EPT-1.2 EMC Plastic TableSKU: 11445 Table top diameter: 47.3 in/1.2 m (D) x 31.5 in/0.8 m (H)Load capability: Up to 220 LbsMaterial structure: StyrodurDielectric constant e at 1 MHz: 1.2Material table top (removable) with a grid of 100 mm x 100 mm (3.9x 3.9 in): Pertinax t = 2 mm (0.07 in)In Stock
- 
            ESA EMI Spectrum Analyzer for Precompliance TestingSKU: 112048 Applications: Conducted Emissions, Radiated Emissions, Spectrum Analyzers for EMCPre-programmed Test Limits: FCC Part 15, CISPR 22, and moreMax Frequency: 1 GHz, 3 GHz or 7.5 GHzMin Frequency: 9 kHzSweep/Test Speed: Slow$195.00 - $995.00IN STOCK
- 
            $197.00
- 
            GRC Series Ground Cable w/ 470k Ohm Resistors for ESD Voltage BleedingSKU: 30180 Total Resistance: 1 MOhm (± 1%)Connector Type: 1/4" SpadeCable Voltae Withstand: 40kV (150 degrees C)Length: 1.5, 2 and 3 MetersResistance: HV Precision Resistors (1% tolerance)$279.00 - $499.00In Stock
- 
            GTEM 250 Electromagnetic Transverse Waveguide CellSKU: sku-677 Max EUT Size: 8" x 8" x 6"Frequency Range: DC - 20 GHzMax Input Power (CW): 1000 WattsMax Input Power (Pulse): 2,500 WattsDimensions (Footprint): 50" x 25" x 17"IN STOCK
 
 
             
                 
                 
                 
                 
                 
                 
                 
                 
                 
                 
                