Voltage Dips and Interruptions Testers Test Equipment
- 
            Haefely PLINE 1610 Voltage Failure SimulatorSKU: 10503 Test Standards: IEC/EN 61000-4-11, IEC/EN 61000-4-29Voltage Range: 0 - 264 VoltsFrequency Range: 48 to 62 HzCurrent Range: up to 16A rms continuous, 20A @ 80%, 23A @ 70%, 40A @ 40%(rms for 5s)Phase synchronization: Synchronous 0 to 360 resolution, Asynchronous$1,275.00 - $19,750.00Typically In Stock
- 
            Noiseken VDS-2002 Voltage Dip and Swell SimulatorSKU: 64232 EUT Input Voltage Range: 90 - 264 VAC 50/60Hz, 0-125 VDCEUT Output Voltage Range: 0 - Input Voltage RangeOutput Power Rating: 4.224kVAOutput Current Capability: 16 Amps continouslyRise time / fall time: 1〜5μs 100 ohm loadedIN STOCK
- 
            Rent Chroma 61605 Single Phase AC Power SourceSKU: sku-2125 Weight: 71 kg/165.2 lbsCurrent rating: 120 ampsDimensions: 400 x 482 x 600 mm (15.75 x 19 x 24 in)Frequency Range: DC, 15 Hz - 1.2 kHz (.15% accuracy)Output current: 16 Amps RMS (96 Amps Peak)$1,295.00
- 
            3ctest PFS Single Phase Power Fail SimulatorSKU: 21108 EUT max. Voltage: 55V - 300VEUT max. current: 6A - 55ADip Voltage & Variation Levels: 0% through 100%Test Standards: IEC/EN 61000-4-11, IEC/EN 61000-4-29Applications: EMC Precompliance Testing, Conducted Immunity4-6 Weeks
- 
            EM Test PFS 503N32 Power Fail Simulator, 3-phase 3x480V AC (p-p) max. 32ASKU: sku-549 Weight: app. 28kg;Current Rating: Max. 32ADimensions: 19"/6 HUDips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29Frequency: 50Hz/60Hz, Single phase application
- 
            Teseq INA 6501 Manual Step Transformer for AC Dips & InterruptionsSKU: sku-116 Accuracy: ±5%Input voltage UIN: 0 to 250 VAC, 50/60 HzOutput voltage UVAR: 4 steps: 0% - 40% - 70% - 80% of UINVoltage change with load: 00% output, 0 to 16 A less than 5%; 80% output, 0 to 20 A less than 5%; 70% output, 0 to 23 A less than 5%; 40% output, 0 to 40 A less than 5%$2,060.00
- 
            Haefely DIP 116 Automatic Dips Transformer 16 Amps 40/70/80%SKU: HAE-DIP116 Test Standards: IEC 61000-4-11Typically In Stock
- 
            EM Test PFS 500 Power Fail Simulator for EN/IEC 61000-4-11SKU: 1144 Test Standards: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29Applications: Voltage dips, Voltage interruptions, Voltage variations, Inverse, EMC Precompliance Testing, Conducted ImmunityEUT Power Handling: AC up to 240V/16A$4,750.001 Unit
- 
            3ctest Voltage Dips & Power Frequency Module (VMT, VVT, MFT)SKU: sku-565 Applications: EMC Precompliance Testing, Conducted ImmunityTest Standards: IEC/EN 61000-4-11, IEC/EN 61000-4-29Compatible Transient Generators: 3ctest CCS 600Inquire for Availability
- 
            Schloder VIS 1700 Voltage Interruption SimulatorSKU: 21784 Communication: BNC outputs (on rear) for voltage, current and scope triggeringCoupling: BNCDips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29General Data: Technical DetailsMains & EUT Connections: 4mm banana lineTypically In Stock
- 
            Teseq INA 6502 PQF/Dip Transformer for NSG 3060SKU: 3955 Test Standards: IEC/EN 61000-4-11Compatible Generators: Teseq NSG 3060, Teseq NSG 3040Applications: Conducted Immunity$549.00 - $1,600.00In stock
 
 
                 
                 
                 
                 
                 
                 
                 
                 
                 
                