Description
EM Test AMP 200N Application:
AMP 200N - Low-frequency signal source for supply simulation and magnetic field testing
The AMP 200N has been designed as a low-frequency signal source to generate sinusoidal signals used to simulate ripple noise and ground shift noise as required by a variety of standards in the automotive industry e.g. as per Ford EMC-CS-2009.1, CI 210 and CI 250 as well as RI 150. The AMP 200N is controlled by the EM TEST Autowave to also allow the generation of non-sinusoidal and customised signals. Additionally, the AMP 200N can be used to generate magnetic fields by means of a radiation loop or small Helmholtz coils as per RI 140 of Ford EMC-CS-2009.1.
Standards
- Chrysler CS-11809 (2009)
- Chrysler CS-11979
- Chrysler DC-11224 Rev.A
- DaimlerChrysler DC-10615
- DaimlerChrysler DC-11224
- Ford EMC-CS-2009.1
- GMW 3172
- Jaguar JLR-EMC-CS V1.0 Amd 4
- MAN 3285
- SAE J1113-2
- Tata TST/TS/WI/257
Benefits
AMP 200N - Signal generator/amplifier solution for ripple noise and magnetic field testing
The AMP 200N unifies a low-frequency signal generator and a powerful amplifier module giving a maximum amplitude of 150V peak-to-peak as required e.g. by Ford EMC-CS-2009.1. It generates both sinusoidal and transient signals. Equipped with a DDS it generates any sinusoidal signal with a frequency up to 250kHz. The AMP 200N is controlled by the EM TEST AutoWave in order to generate any sinusoidal or non-sinusoidal/transient signals and is therefore fully supported by the autowave.control software with its exhaustive library of pre-programmed standards and its outstanding reporting and documentation capabilities.
The AMP 200N can also be used for magnetic field testing using a Radiation Loop and Loop Sensor. Extended by the optional measuring module the AMP 200N offers means for frequency-selective current measurement, voltage measurement and measurement of the magnetic field strength.
The AMP 200N can also be used for magnetic field testing using a Radiation Loop and Loop Sensor. Extended by the optional measuring module the AMP 200N offers means for frequency-selective current measurement, voltage measurement and measurement of the magnetic field strength.
Optional Product:
EM Test AMP 200N1.1 - High frequency option up to 500 kHz
Videos
Custom Field
Weight Approx. 18kg
Amplifiers low-frequency signal source with amplifier
Dimensions 19", 3HU
(500mm x 449mm x 133mm)
Frequency range DC - 250kHz
General Data Technical Details
Harmonic Distortion (THD) less than 0.1%
Operating Temperature 10°C - 40°C
Output current Max. 5Arms up to 200kHz
Max. 4Arms 200kHz - 250kHz
Output Impedance 30 mOhm @ 1 kHz
Output voltage 50Vrms, max. 140V(p-p) up to
100kHz
30Vrms 100kHz - 250kHz
Protection - Short circuit
- Overtemperature
Signal power 250W (nominal)
Supply Voltage 115 V +10/-02%, 50/60 Hz or
230 V +10/-15%, 50/60 Hz