Test Type Categories
Test Type Test Equipment
-
Haefely PIM 150 Oscillating Wave Surge Generator
SKU: 10526
Burst frequency: 100 kHz & 1 MHzCoupling: Single & Multiple PathMains & EUT Connections: HV connector & CDNSource Impedance: 200 ohmsStandards Met: IEC 61000-4-18 Power & Data lines; ANSI C37.90.1, IEC 60255-22-1, IEEE 1613In Stock -
Teseq NSG 4060 Low Frequency Immunity Generator
SKU: 11497
Frequency Range: DC/3 Hz - 150 kHzMax Output Voltage: 30 Vrms (up to 300V short duration tests)Pulse Modulation Freq Range: 3 Hz to 10 kHzOutput Impedance: 50 Ohms from the generator (1 or 10 Ohms with couplers)Output Connections: Two 4mm Safety BananasTypically in Stock -
PMM 1008 Magnetic Field Generator with Loop Antenna, 1200 A, 50/60 Hz, IEC/EN 61000-4-8
SKU: sku-489
Weight: 57,3 kgDimensions: 550 x 2000 x 650 mmOperating Temperature: -10 °C to +40 °CSupply Voltage: 230 Vac ± 10 % - 50/60 Hz, 16 A max -
PMM (Narda) 6630 USB RF Power Sensor 9 KHz - 3 GHz, 1 W
SKU: sku-470
Weight: 0.12 kgDimensions: 30 x 30 x 95 mmGeneral Data: Technical DetailsRF Field Probe Connector: N male, 50 ΩRF Field Probe Frequency Range: 9 kHz to 3 GHz -
Com-Power LIT-930A 9kHz to 30MHz Transient Limiter
SKU: 8409
Connector: N type (input and output)Dimensions: L 4.3” (100 mm) W 2.0” (50 mm) H 1.5” (35 mm)Frequency Range: 9 kHz - 30 MHzInput: 4 Watts CW (+36 dBm) ±50 VdcInsertion Loss: 10 dB +1.5 / -0.5 dB*$650.00Typically In Stock -
Com-Power LIT-153A 150kHz to 30MHz Transient Limiter
SKU: sku-446
Connector: N type (input and output)Dimensions: L 3.0” (75 mm) W 1.25” (32 mm) H 1.25” (32 mm)Frequency Range: 150 kHz - 30 MHzInput: 2 Watts CW (+33 dBm) ±10 VdcInsertion Loss: 10 dB +1.5 / -0.5 dB*$430.00 -
Narda PMM Rad-IS RF Radiated Immunity System for IEC/EN 61000-4-3
SKU: 10419
Application/Test Type: EMC RF/Radiated Susceptibility TestingConnector: BNC Input, Output Type N(f)Frequency Range: 9 kHz to 3 GHzImpedance: 50 OhmsInput: 115/230 V 50/60 Hz -
Inquire for Availability
-
-
EM Test CWS 500N1 Continuous Wave Simulator for IEC 61000-4-6
SKU: sku-410
Weight: 17 kg (37.5 Pounds)Application/Test Type: Create and output RF currents as well as measure input for CDN and clamp calibration as well as current monitor for clamp applicationsDimensions: 19"/3 HUFrequency Range: Sinus (CW) 100kHz to 300MHz Frequency bands 100kHz to 9.999MHz 10MHz to 99.99MHz 100MHz to 300MHzImpedance: 50 OhmsInquire for Availability -
Radiated Immunity Test System for IEC 61000-4-20 TEM Waveguides
SKU: 10393
Application/Test Type: Radiated Susceptibility TestingFrequency Range: 30 to 1000 MHzMax Radiated Field Strength: Lowest field strength: 1 V/m at 600 mm septum height* Highest field strength: approx. 18 V/m at 600 mm septum height*Maximum Continuous Power: Lowest forward power: 15 dBm* Highest forward power: 41 dBm*Test Standards: MIL-461 RS103, IEC/EN 61000-4-3, ISO 11452-2, DO-160 Section 20 -
Teseq CDN 118-T4 Coupling Decoupling Network set for 1.2/50 µs and 10/700 µs Surge Pulses on 1 or 2 twisted pairs
SKU: 30093
Application/Test Type: 1.2/50 μs (2 ohms) and 10/700 μs (15 ohms) pulse up to 6.6 kV line to ground, 3 kV line to line (Pulse frequency: 3 per minute)Current Rating: 0.5 AmpsDecoupling chokes 1 kHz: 20 mH nominalDimensions: 335 x 232 x 180mmMains & EUT Connections: 4 mm safety banana; Fischer 103Inquire for Lead Time