EM Test Conducted LF/RF Immunity

EM TEST offers a variety of testing solutions for conducted LF/RF immunity as per EN/IEC 61000-4-6, for BCI (bulk current injection) and magnetic field tests, ripple noise and common-mode testing as per EN/IEC 61000-4-16.

EM Test Conducted LF/RF Immunity There are 6 products.

Showing 1 - 6 of 6 items
    • Test procedure acc. IEC 61000-4-6 Ed. 4
    • Built-in amplifier saturation and linearity check
    • Built-in power amplifier 25 to 80 watts, 10 kHz to 400 MHz
    • Built-in power meter, 9 kHz to 1 GHz
    • Built-in dual directional coupler
    • Automatic calibration via built-in power meter
    • Connection for external amplifiers up to 1 GHz
    • USB-Interface
    • Software for Windows 7, Windows 8
    Typically In Stock
    Request Quote/More Info
    • Most compact equipment
    • Supports BCI testing as per various standard requirements
    • Basic frequency range 9 kHz up to 400 MHz
    • Extendable frequency range up to 1 GHz
    • Built-in 110 W class A amplifier up to 400 MHz
    • Built-in RF switch to connect external amplifier
    • Built-in directional coupler
    • Built-in 3-channel power meter up to 1 GHz
    4-6 Weeks
    Request Quote/More Info
    • Most compact equipment for ripple noise on ac/dc supplies and magnetic fields
    • Built-in LF signal generator
    • Built-in LF amplifier
    • Built-in LF transformer 2:
    • Built-in frequency-selective voltage and current meter
    • Built-in load resistors
    • Automatic self-calibration
    • Frequency Range: 10 Hz - 250 kHz
    4-6 Weeks
    Request Quote/More Info
    • Compact equipment for common-mode disturbances as per IEC 61000-4-16
    • Built-in LF signal generator and LF amplifier
    • Sweep mode capability 10Hz to 165kHz
    • Built-in rectifier module for DC testing
    • Option for Electricity Meter testing acc IEC 61000-4-19 Annex C
    4-6 Weeks
    Request Quote/More Info
    • Monthly Rental - Ships Immediately
    • CDN, BCI Probe or EM Clamp Required to complete test setup
    • Meet RF & Conducted Immunity Compliance Standards:
      • EN/IEC 61000-4-6
      • MIL-STD461 CS114
      • RTCA/DO160 Section 20
      • ISO 11452 part 4 BCI
      • ISO 11452 part 5 Stripline
      • IEC 60601-1-2
      • EN 61000-6-1/EN 61000-6-2
      • Various Automotive Manufacturer's Specifications
    In Stock
    Request Quote/More Info
    • Signalgenerator 9kHz to 1GHz
    • Amplitude modulation: 1Hz to 3kHz (0% to 95%)
    • Pulse modulation: 1Hz - 1kHz (10% to 90%)
    • Built-in amplifier, 100kHz to 300MHz 
    • Built-in current monitor, 9kHz to 1GHz  
    Typically In Stock
    Request Quote/More Info
Showing 1 - 6 of 6 items