  • Teseq CDN AF Series Coupling/Decoupling Network for Unscreened/Unbalanced Lines

    SKU: sku-230

    Weight: 1.5 kg (3.3 lbs)
    Application/Test Type: Coupling / decoupling network (CDN) used for all unscreened, unbalanced lines, carrying low current
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 2300 MHz: 150 Ω +60 Ω / -45 Ω; 230 MHz to 300 MHz 1): 150 Ω +60 Ω / -60 Ω
    Current Rating: 200 mA to 4 Amps (refer to data sheet for exact model specifications)
    Decoupling of Common Mode Disturbance: 10 kHz: Over 10 dB:150 kHz: Over 35 dB: 26 MHz: Over 45 dB: 80 MHz: Over 25 dB;150 kHz: Over 30 dB: 1.5 MHz: Over 60 dB: 30 MHz: Over 50 dB: 230 MHz: Under 30 dB (refer to data sheet for some exceptions)
  • Teseq CDN T Series Coupling Network for Unscreened Communication/Data Lines

    SKU: sku-228

    Weight: 0.5 kg (1.1 LB.'s)
    Application/Test Type: EMC testing for unscreened data communication/telecom lines (Power over Ethernet, 1100BaseT4, 100Base VG-AnyLan, 1000BaseT, Token ring, ISDN, 10BaseT, 100BaseTX, ATM, FDDI, TP-PMD
    Common Mode Impedance: 10 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 80 MHz: 150 Ω +60 Ω / -45 Ω; 80 MHz to (230) 300 MHz: 150 Ω +60 Ω / -60 Ω
    Current Rating: 400 mA (line), 800 mA (pair)
    Decoupling of Common Mode Disturbance: 10 kHz: Over 20 dB; 1.5 MHz / 30 MHz: Over 55 dB; 80 MHz: Over 45 dB; 230 MHz: Over 35 dB;
  • Teseq CDN M5 5-Line Coupling Network for AC Power Lines, 16-32 Amps

    SKU: sku-227

    Weight: 6.5 kg (14.3 LB.'s)
    Application/Test Type: 5 mains AC power lines emissions testing up to 32 Amps (3L+N+PE)
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 32 Amps Maximum
    Decoupling of Common Mode Disturbance: Greater than 30 dB
  • Teseq CDN M432 32 Amp Coupling/Dcoupling Network

    SKU: sku-226

    Weight: 6.5 kg (14.3 LB.'s)
    Application/Test Type: 4 mains AC power lines emissions testing up to 32 Amps (2L+N+PE), (3L+PE), optional (3L+N)
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 32 Amps Maximum
    Decoupling of Common Mode Disturbance: Greater than 30 dB
    $270.00
  • Teseq CDN M416 4-Line Coupling/Decoupling Network

    SKU: sku-225

    Weight: 700 grams (1.5 LB.'s)
    Application/Test Type: 3 power lines, (L+N+PE), (2L+PE), (Optional L+L+L)
    Common Mode Impedance: 150 Ω +10/-20 Ω
    Current Rating: 10 Amps Maximum
    Decoupling of Common Mode Disturbance: Greater than 30 dB
  • Teseq CDN M210B Coupling Network with CEE 7/17 EUT Port & IEC 60320 C14 AE Port

    SKU: sku-223

    Weight: 3.3 Lbs (1.5 kg)
    Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 10 Amps
    Decoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dB
    $1,020.00 - $1,445.00
  • Teseq CDN M1-10 Coupling Network 10 KHz to 80 MHz for PE Lines

    SKU: sku-222

    Weight: 3.3 Lbs (1.5 kg)
    Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)
    Common Mode Impedance: 10 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 80 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: Current max. (no saturation): 300 mA; Current max. (1 s for PE line test): 25 A
    Dimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)
    $790.00