Description
Teseq’s CDN 117 coupling-decoupling network enables convenient testing with surge pulses of 1.2/50 μs on data, signal or peripheral lines, as specified in many product standards. The test method, severity levels, permissible reaction of the EUT and specification of the coupling networks are included in IEC/EN 61000-4-5.
Teseq CDN 117 Features:
- Telecom line surge testing
- Max. Operating Voltage: 250 Volts
- Max Operating Current: 1.5 Amps
- Complies with IEC/EN 61000-4-5
Teseq CDN 117 Includes:
- The decoupling network itself
- Interface cables to the surge generator
- A coupling device with a 0.5 μF capacitor
- A coupling device with a spark gap device
Videos
Custom Field
Weight 2.1 kg (4.6 lbs)
Application/Test Type 1.2 / 50 μs pulse up to 6.6 kV
Coupling INA 170: spark gap device, 90 V trip voltage;
INA 174A: capacitor 0.5 μF
Current Rating 1.5 Amps
Decoupling chokes 1 kHz 20 mH nominal
Dimensions 300 mm x 55 mm x 80 mm
Ohmic resistance per path Less than 2.5 Ω
RF Connector 4 mm safety banana; Fischer 103
Series resistor 2 x 40 Ω, 6 W
Transmission 3 dB BW 800 Hz
Voltage Rating 250 Volts AC/DC