Test Type Categories
Test Type Test Equipment
-
Narda EFD-9091 E-Field Probe 100 MHz to 90 GHz
SKU: 8485
Measurement Range: 0.5 to 400 V/m (CW), Typ. 0.5 to 61.4 V/m (True RMS)Dynamic Range: 58 dB (nominal)Flatness: ±3 dB (300 MHz to 40 GHz), +3/-6 dB (100 MHz to 60 GHz)Isotropic Deviation: ±1.25 dB (100 MHz to 10 GHz), ±2 dB (>10 GHz to 26.5 GHz)Applications: Radio link, telecommunications, satellite, and radarIn Stock -
NoiseKen LSS-F03-C3A Lightning Surge Simulator
SKU: 8477
Condition: 10 - Basically brand newCombination/Wave Surge Output: 0.5 - 15 kVLine for EUT: 2 lines / 4 lines DC 50 V / 100 mA MAXWeight: 750 lbsCoupling: AC/DC lines CDN, and Telecom lines CDNIn Stock -
Ladybug LB479A Peak and Pulse Power Sensor 10 MHz - 8 GHz
SKU: 8289
Frequency Range: 10 MHz to 8 GHz (functional to 10 GHz)Dynamic Range: -60 dBm to +20 dBmConnector: SMA Male 3.5 mmMatch: 1.09:1 VSWR (27 dB Return Loss)Time Base: +/- 50 ppm$199.00 - $2,400.00In Stock -
Keysight (Agilent) N9010B EXA Signal Analyzer 10 Hz – 26.5 GHz
SKU: 8317
Frequency Range: 10 Hz to 26.5 GHzRange: 0 Hz (zero span), 10 Hz to maximum frequency of instrumentResolution: 2 HzSweep Time Range: Span ≥ 10 Hz = 1 ms to 4000 sResolution Bandwidth: 1 Hz to 3 MHz (10 % steps), 4, 5, 6, 8 MHz$1,945.00In Stock -
Narda EFD-1891 E-Field Probe 2 MHz - 18 GHz
SKU: 7202
Measurement Range: 0.6 to 800 V/m (CW), 0.6 to 65 V/m typ. (True RMS)Dynamic Range: 62.5 dB (nominal)Flatness: +1/-1.5 dB (10 MHz to 3 GHz), +2/-1.5 dB (>3 GHz to 11 GHz)Isotropic Deviation: ±1 dB (10 MHz to 5 GHz), ±2.25 dB (> 5 GHz to 18 GHz)Applications: Broadcasting, telecommunications, and satelliteIn Stock -
SS6G-100 Solid State High Power Amplifier
SKU: 8221
Frequency Range: 1 GHz - 6 GHzRF Input Power: 0 dBm (1 mW) maxGain: 53 dB typ (50 dB min)Applications: Radiated Immunity TestingTest Standards: IEC/EN 61000-4-3, MIL-STD-461 RS103, DO-160 Section 20, SAE J113/4In Stock -
Conducted Emissions Test Setup
SKU: 7077
Applications: Conducted emissions testing on power and data lines, CE MarkingTest Standards: IEC 61000-4-7, IEC 61000-4-30, IEC-61000-4-19, CISPR 11, CISPR 25, CISPR 32, FCC Part 15, MIL-STD 461, ANSI C63.4, DO-160 and moreMeasurement Range: 1 kHz - 1 GHz (150 kHz - 30 MHz typical)Power Handling: up to 1,000 Volts and 1,000 AmpsOEM Measurement Receivers Available: Rohde & Schwarz, Keysight, Siglent, Rigol, PMM, Amplifier Research, Frankonia$590.00 - $14,950.00In Stock -
DO-160 Section 20 RF Conducted Susceptibility (CS) Test System
SKU: 10202
Frequency Range: 4 kHz - 1 GHz (10 kHz - 400 MHz typical)Current Levels: up to 1 AApplication: Bulk Current Injection (BCI) TestingSetup & Calibration: Conducted Susceptibility Testing, EMC Precompliance TestingShipping: Same Day (Some systems may need to go freight)$2,250.00 - $4,950.00In Stock -
DO-160 Section 20 Radiated Susceptibility (RS) Test System
SKU: 10116
Frequency Range: 100 MHz - 18 GHzElectric Field Strengths: up to 200 V/m CW and 600 V/m PulseSetup & Calibration: Quick Start Guide ProvidedElectric Field Probes: NIST or Accredited CalibrationsIndustry: Military & Aerospace$9,750.00 - $24,750.00In Stock -
Maturo TT 1.2 m Turn Table
SKU: sku-5248
Diameter: 1.2 mLoad Capability: 500 kgApplications: Radiated Immunity, Radiated EmissionsTest Standards: CISPR 16-1-4, IEC 61000-4-3, FCC Part 15 BTypically In Stock -
3ctest EDS MAX20 ESD Simulator Gun
SKU: 141241
Output Voltage Range: 500 Volts to 20kVStep Voltage: 100VCompliance Standards: IEC/EN 61000-4-2:2025Pre-programmed IEC Test Routines?: YesRemote & Automation Control?: Yes (via fiber optic interface)$475.00 - $8,975.00Typically In Stock -
Applied Systems Engineering 176 2kW TWT Pulse Amplifiers
SKU: 7349
Duty Cycle: 6%Frequency Range: 1 GHz to 18 GHzPulse Width Range: 0.07 to 100 usPRF Range: 0 to 400 kHzRF Rise / Fall Time: 15 ns, Maximum$5,500.00Typically In Stock