PMM (Narda) 6630 USB RF Power Sensor 9 KHz - 3 GHz, 1 W

Manufacturer:
PMM
Weight:
0.12 kg
Dimensions:
30 x 30 x 95 mm
General Data:
Technical Details
RF Field Probe Connector:
N male, 50 Ω
RF Field Probe Frequency Range:
9 kHz to 3 GHz
RF Field Probe Max SWR:
10 kHz to 300 kHz 1,10 from +30 dBm to -9 dBm 300 kHz to 100 MHz 1,05 100 MHz to 1 GHz 1,10 1 GHz to 3 GHz 1,25 10 kHz to 3 GHz 1,20 from -9 dBm to -40 dBm
RF Field Probe Maximum Input Power:
2 W peak envelope max 300 ms
RF Field Probe Measurement Accuracy:
less than 0,35 dB
RF Field Probe Power Linearity:
-40 dBm to +30 dBm @ 50 MHz 0,2 dB
RF Field Probe Power Measurement Range:
100 nW to 1 W (-40 dBm to +30 dBm)
RF Field Probes:
Power Sensor
Supply Voltage:
5 Volt DC – 100 mA (from USB Port)

 

No reviews yet Write a Review
SKU:
sku-470

 

 

Due to tariff increases, some items in our catalog are subject to additional costs when purchased.


Getting Started...

Check out our Google Reviews

Overview

PMM (Narda) 6630 USB RF Power Sensor Description:

The 6630 Power Sensor is the ideal solution for true RMS RF power measurements in a wide variety of applications, including EMC immunity testing, CDN and clamp calibration, as well as for measuring the input power of antennas or GTEM cells. Using a directional coupler, both direct and reflected power can be measured easily and accurately.

The optional 6630FOA Fiber Optic Adapter allows communication with a fiber optic link up to 80 meters long, providing the utmost immunity even in the harshest electromagnetic environments, for applications such as bulk current injection tests and in-chamber installations.

The 6630 Power Sensor can be coupled with the SW WIN6630 utility to make it a fully autonomous meter, or act as a stand-alone sensor. Through a straightforward protocol it can communicate with customer-made SW, making it the ideal feedback tool for automated systems.

Key Considerations

Manufacturer:
PMM
Weight:
0.12 kg
Dimensions:
30 x 30 x 95 mm
General Data:
Technical Details
RF Field Probe Connector:
N male, 50 Ω
RF Field Probe Frequency Range:
9 kHz to 3 GHz
RF Field Probe Max SWR:
10 kHz to 300 kHz 1,10 from +30 dBm to -9 dBm 300 kHz to 100 MHz 1,05 100 MHz to 1 GHz 1,10 1 GHz to 3 GHz 1,25 10 kHz to 3 GHz 1,20 from -9 dBm to -40 dBm
RF Field Probe Maximum Input Power:
2 W peak envelope max 300 ms
RF Field Probe Measurement Accuracy:
less than 0,35 dB
RF Field Probe Power Linearity:
-40 dBm to +30 dBm @ 50 MHz 0,2 dB
RF Field Probe Power Measurement Range:
100 nW to 1 W (-40 dBm to +30 dBm)
RF Field Probes:
Power Sensor
Supply Voltage:
5 Volt DC – 100 mA (from USB Port)