Quick Links

Information

EN/IEC 61000-4-6

 

EMC/EMI Testing Services         Radiated Immunity & Susceptibility        Antenna Testing            Emissions Testing

 

The EMC Shop rents this test equipment, allowing for preliminary testing and evaluation before attempting to certify the product. The IEC/EN 61000-4-6 test standard should be purchased, read and followed to develop a suitable test plan and effectively evaluate your product.

 

EN/IEC 61000-4-6 Testing

EN/IEC 61000-4-6 is the normative reference standard to test electronic products immunity to RF conducted injected interference. RF conducted interference is phenomena as simple as placing a wireless device on or near power cables or data lines that can couple wireless through the shielding of those lines and affect associated equipment. More complex situations include cable bundles in a car chassis that may cause the RF conducted affect and impact other lines, and travel to the electronics. RF conducted immunity test equipment will generate more than anticipated RF fields we would expect in the real world. Engineers exercise their equipment across the frequency band, typically 150 kHz to 80 or 230 MHz, to gauge how their product responds to the interference.

Injection Method Selection

EN/IEC 61000-4-6 Injection Method Selection Chart

EN/IEC 61000-4-6 Videos



 

EN/IEC 61000-4-6 Procedure

  • Identify Amount of Ports to EUT
  • Identify Coupling Methods
  • Generate Pass/Fail Criteria
  • Determine 61000-4-6 Test Levels
  • Calibrate System
  • Connect EUT and Test
  • Document Results
  • Troubleshoot Accordingly

EN/IEC 61000-4-6 There are 98 products.

Subcategories

per page
Showing 1 - 12 of 98 items
    • Frequency Range: 9 kHz - 400 MHz
    • For use with BCIP400M BCI Probe or similar
    • ISO 11452-4 
    • IEC 61000-4-6
    • Suitable for probes with diameter of 3.2 to 4.4 cm (1.25 to 1.73 inches)

    Typically In Stock
    Request Quote/More Info
    • Meets civilian and military standards (e.g. IEC/EN 61000-4-3; IEC/EN 61000-4-6;ISO 11452-4; MIL-STD-461G; etc.)
    • Suitable for conducted, radiated and automotive immunity tests
    • 9 kHz to 230 MHz frequency range
    • 10 W power output (15 W from 150 kHz to 80 MHz)
    • 40 dB power gain
    • Class A linear solid-state amplifier
    • 50 Ω input/output impedance
    • Analog meter and LED indicators
    • Fan air cooling
    • Robust and compact construction
    Typically Stocked
    Request Quote/More Info
    • Integrated signal generator 4 kHz to 1 GHz
    • 3 power meter inputs 4 kHz to 1 GHz
    • Integrated class A power amplifier module:
      Multiple EUT monitoring options
      • 45 W, 9 kHz to 1 GHz
    • 5,7“ TFT color display
    • Internal, menu-based control software
    • Basic remote control software and report generator included
    • Optically decoupled remote control
    • Whisper mode
    In Stock
    Request Quote/More Info
  • Request Quote/More Info
    • Coupling/Decoupling Network (CDN) CDN M Type
    • Designed for IEC/EN 61000-4-6 Conducted RF Immunity Testing
    • CDN M016 switchable M2 or M3 (2 or 3 power lines)
    • Types with 4 mm banana sockets
    • 150kHz to 230 MHz (300 MHz)
    • Rent the Teseq M016 CDN
    In Stock
    Request Quote/More Info
    • AC (V): 600
    • DC (V): 1000
    • CDN M-Type
    • Coupling / Decoupling of disturbing signal to unscreened supply lines (mains) AC + DC
    • 150 kHz – 80 MHz
    • Suitable for IEC 61000-4-6
    Typically In Stock
    Request Quote/More Info
  • Quick view
    $389.00 Monthly
    • Frequency Range: 10 kHz to 230 MHz
    • Max Input Power: 125 Watts
    • Insertion Loss: <8 dB between 150 kHz - 100 MHz
    • Aperture: 40 mm (1.57 inches)
    • Ideal for IEC 61000-4-6 BCI Testing
    $389.00
    Typically In Stock
    Request Quote/More Info
    • EM clamp for immunity testing of cables with up to 35 mm diameter
    • High coupling factor: less than 15 watts amplifier output power is required to obtain a test level of 10 V
    • Calibration unit and calibration data are supplied with each instrument
    In Stock
    Request Quote/More Info
    • Coupling networks designed for IEC/EN 61000-4-6
    • T series for unscreened balanced pairs of communication/data lines
    • 1 mm banana sockets for CDN T2-10 and CDN T4-10
    • D Sub 25 adapters to RJ11 and RJ45 sockets for CDN T2xxA, CDN T4xxA and CDN T8 products
    In Stock
    Request Quote/More Info
    • Rent the EMIC-20 EM Clamp
    • EM clamp for immunity testing of cables with up to 20 mm diameter
    • High coupling factor: less than 15 watts amplifier output power is required to obtain a test level of 10 V
    • 10 kHz – 1000 MHz
    • Calibration unit and calibration data are supplied with each instrument
    In Stock
    Request Quote/More Info
    • Frequency Range: 400 MHz - 1.5 GHz
    • Rugged Design
    • 50 Ohm Impedance
    • VSWR 2.0:1
    Typically In Stock
    Request Quote/More Info
  • Typical Lead Time 6 - 8 Weeks
    Request Quote/More Info
Showing 1 - 12 of 98 items