IEC 61000-4-6 EM Clamps Test Equipment, Systems & Solutions
-
EM Test / Luthi EM 101 EM Injection Clamp for IEC/EN 61000-4-6
SKU: sku-1881
Weight: approx. 7 kgApplication/Test Type: Injects the disturbance signal through a combination of inductive and capacitive couplingClamp factor (CF): Max (0.15 to 400 MHz): 4 dB (50 Ī© system) and 13.5 dB (150 Ī© system)Connector: N-type femaleDimensions: 647 mm x 130 mm x 105 mmFrequency Range: 10 kHz to 1000 MHzImpedance: 50 OhmsMax. Cable Diameter: 20 mmMaximum Continuous Power: 0.01 to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 3 min; 230 to 1000 MHz: 50 W for 3 minStandards Met: IEC/EN 61000-4-6; CISPR 24; EN 61000-6-1; EN 61000-6-2; IEC 60533; IEC 60601-1-2; IEC 61326 -
Fischer Custom Communications F-203I-A-23MM, 10kHz - 1GHz, 100 Watts CW
SKU: sku-726
Weight: approx. 7 kgApplication/Test Type: Injects the disturbance signal through a combination of inductive and capacitive couplingConnector: N-type femaleDimensions: 610 x 75 x 135 mmFrequency Range: 10kHz - 1GHzMax. Cable Diameter: 23 mmMaximum Continuous Power: 100 watts CW for 15 minutesStandards Met: IEC/EN 61000-4-6; -
Teseq FT 801 Ferrit Tube EM Decoupling Clamp, 150 kHz to 1 GHz, 35 mm Cable Diameter
SKU: sku-673
Weight: approx. 8 kgApplication/Test Type: decoupling network (ferrite tube) for immunity test according to IECā/āEN 61000-4-6Dimensions: 670 mm x 70 mm x 80 mmFrequency Range: 150 kHz to 1000 MHzMax. Cable Diameter: 35 mmStandards Met: IEC/EN 61000-4-6 CISPR 24 EN 61000-6-1 EN 61000-6-2 IEC 60533 IEC 60601-1-2 IEC 61326 -
Teseq MDS 21B EMC Absorbing Clamp for Disturbance Power Measuring, w/ 6 dB Attenuator & RF Cable
SKU: sku-559
Weight: approx. 6.3 kgCurrent Rating: 30 ADimensions: 610 mm x 115 mm x 80 mmFrequency Range: 30 MHz to 1000 MHzImpedance: 50 Ī©RF Connector: N, female -
Com-Power CLA-150 32mm Absorbing Clamp
SKU: sku-266
Weight: 21 lbs (9.5 Kg)Aperture: 34.9 mm (1.37 inches)Application/Test Type: Measurement of direct field strength from EUT supply cablesClamp factor (CF): -3 dB to +4 dBDimensions: 627 x 114 x 165 mm (24.7 x .4.5 x 6.5 inches)Frequency Range: 30 MHz to 1000 MHzIsolated lines under test: Power supply lines and other connecting linesMax. Cable Diameter: 32 mm (1.26 inches)Min. site attenuation: 14 dB to 21 dBRF Connector: BNC (f), 50 OhmsStandards Met: CISPR 14 -
Com-Power CLA-050 10mm Absorbing Clamp
SKU: sku-265
Weight: 5 kg (11.5 lbs)Aperture: 12.7 mm (0.5 inches)Application/Test Type: Measurement of direct field strength from EUT supply cablesClamp factor (CF): -3 dB to +4 dBDimensions: 627 x 114 x 144 mm (24.7 x .4.5 x 5.7 inches)Frequency Range: 30 MHz to 1000 MHzIsolated lines under test: Power supply lines and other connecting linesMax. Cable Diameter: 10 mm (0.39 inches)Min. site attenuation: 14 dB to 21 dBRF Connector: BNC (f), 50 OhmsStandards Met: CISPR 14 -
Teseq KEMA 801A RF Attenuation Clamp/Decoupling Network for IEC 61000-4-6
SKU: sku-122
Weight: approx. 5.5 kgDimensions: 670 mm x 100 mm x 79 mmFrequency Range: 150 kHz to 1000 MHzMax. Cable Diameter: 20 mmStandards Met: IEC/EN 61000-4-6; CISPR 24; EN 61000-6-1; EN 61000-6-2; IEC 60533; IEC 60601-1-2; IEC 61326 -
Teseq (Schaffner) KEMZ 801A EM Clamp Conform with IEC/EN 61000-4-6
SKU: sku-119
Weight: approx. 7 kgApplication/Test Type: Injects the disturbance signal through a combination of inductive and capacitive couplingClamp factor (CF): Max (0.15 to 400 MHz): 4 dB (50 Ī© system) and 13.5 dB (150 Ī© system)Connector: N-type femaleDimensions: 647 mm x 130 mm x 105 mmFrequency Range: 10 kHz to 1000 MHzImpedance: 50 OhmsMax. Cable Diameter: 20 mmMaximum Continuous Power: 0.01 to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 3 min; 230 to 1000 MHz: 50 W for 3 minStandards Met: IEC/EN 61000-4-6; CISPR 24; EN 61000-6-1; EN 61000-6-2; IEC 60533; IEC 60601-1-2; IEC 61326 -
INQUIRE
-
EMIC-20 EM Injection Clamp for IEC/EN 61000-4-6 Immunity Test
SKU: 7851
Standards: EN/IEC 61000-4-6Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive couplingClamp factor (CF): -.5 dB at 100 kHz to -4 dB at 1 GHz (Min -7 dB at 700 MHzConnector: N-type femaleDimensions: 632 mm x 120 mm x 80 mmFrequency Range: 10 kHz to 1000 MHzMax. Cable Diameter: 20 mmMaximum Continuous Power: 0.15 to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 5 min; 230 to 1000 MHz: 50 W for 3 min$595.00Typically In Stock -
Com-Power CLEM-6146 RF Injection Device for Conducted Immunity
SKU: sku-524-1
Standards: EN/IEC 61000-4-6NOTE: Our price includes CLEMA-6146 calibration adapters (150 Ohm to 50 Ohm)Frequency Range: 10 kHz to 1000 MHzMax. Cable Diameter: 0.75"Maximum Continuous Power: 10 kHz to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 5 min; 230 to 1000 MHz: 50 W for 3 min$11,780.00Inquire for Lead Time -
EMIC-35 Current Injection Clamp for RF Conducted Immunity Testing
SKU: sku-2132
Weight: approx. 14 kgApplication/Test Type: Injects the disturbance signal through a combination of inductive and capacitive couplingClamp factor (CF): -.6 dB at 100 kHz to -2.2 dB at 1 GHz (Min -4 dB at 700 MHzConnector: N-type femaleDimensions: 666 mm x 135 mm x 120 mmFrequency Range: 10 kHz to 1000 MHzImpedance: 50 OhmsMax. Cable Diameter: 35 mmMaximum Continuous Power: 0.15 to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 5 min; 230 to 1000 MHz: 50 W for 3 minStandards Met: IEC/EN 61000-4-6; CISPR 24; EN 61000-6-1; EN 61000-6-2; IEC 60533; IEC 60601-1-2; IEC 61326