EM Test
SKU: sku-2169
EM Test Surge, EFT, PQF, Ring Wave Immunity System for 3 Phase, 100 Amp EUT
Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts, Ring WaveStandards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-12 IEC/EN 61000-4-29Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITMax EUT AC Voltage (w/ Built in CDN): 480 VoltsMax EUT AC Current (w/ Built in CDN): 100 Amps (Per Phase)Max EUT DC Voltage (w/ Built in CDN): 1000 VoltsMax EUT DC Current (w/ Built in CDN): 100 AmpsPeak inrush current capability: 500 AmpsEFT/Burst Pulse Output Capability: 5.5 kVCombination/Wave Surge Output Capability: 6.6 kVExternal Coupling: Data Lines (EFT & Surge)Dips & Interrupts: 40%, 70%, 80%; Interrupts - 0% (short and open)Ring Wave: 100 kHz, 6 kV$0.00RENTAL ONLY -
SKU: sku-1918
3 Phase Harmonics & Flicker Test System IEC 61000-3-11 and 3-12
Standards Met: IEC 61000-3-11, IEC 61000-3-12, IEC 61000-3-2, IEC 61000-3-2, IEC 61000-3-3, IEC 61000-4-7, IEC 60601-1-2 and more$0.00 -
EM Test
SKU: sku-1917
EM Test AIF 503N32.1 3-Phase Flicker Impedance Network
Standards Met: IEC 61000-3-11, IEC 61000-3-12, IEC 61000-3-2, IEC 61000-3-3, IEC 61000-4-7 and moreApplication/Test Type: Medical Device EMC TestingBuilt-in Power Analyzer: EM Test DPA 503NCurrent Handling: 32 Amps per phase$0.00RENTAL ONLY -
EM Test
SKU: sku-1292
EM Test PFS 500 Power Fail Simulator for EN/IEC 61000-4-11
Weight: app. 28kg;Current Rating: Max. 16 AmpsDimensions: 19"/6 HUDips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29Peak current: 500 Amps inrushPhase synchronization: phase angle 0° - 360° (1 Degree Resolution)Repetition rate: 0 - 99s, 16-500 HzSupply Voltage: 115V/230V; +10/-15%$0.00 -
EM Test
SKU: sku-1195
Complete IEC/EN Test Rack for CE Marking and Conducted Immunity Certification
Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & VariationsStandards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-29Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITMax EUT AC Voltage (w/ Built in CDN): 264 VoltsMax EUT AC Current (w/ Built in CDN): 16 AmpsMax EUT DC Voltage (w/ Built in CDN): 220 VoltsMax EUT DC Current (w/ Built in CDN): 10 AmpsPeak inrush current capability: 500 A (at 230 V)EFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kACombination/Wave Surge Output Capability: ±200 V to 4.4 kV (in 1 V steps)External Coupling: Data Lines (EFT & Surge), 3PH EUT$0.00 -
Was:$48,000.00$14,400.00
-
EM Test
SKU: sku-921
Monthly Rental EM Test CWS 500N Continuous Wave Simulator for IEC 61000-4-6
Weight: 17 kg (37.5 Pounds)Application/Test Type: Create and output RF currents as well as measure input for CDN and clamp calibration as well as current monitor for clamp applicationsDimensions: 19"/3 HUFrequency Range: Sinus (CW) 100kHz to 300MHz Frequency bands 100kHz to 9.999MHz 10MHz to 99.99MHz 100MHz to 300MHzImpedance: 50 OhmsInput: 115 V to 230 V +10/-15 %, 50/60 Hz (380 Watts Max)Maximum Continuous Power: 80W (nominal)Standards Met: IEC 61000-4-6Test Routines: Quick Start, User Test Routines, Standards Test Routines (IEC/EN 61000-4-6), Cal Procedure, ServiceVoltage Rating: 1 V to 30 Volts Max$0.00 -
EM Test
SKU: sku-817
EM Test LD 200N Load Dump Generator for ISO 16750-2
Output: +/- output Safety laboratory connectors Coupling To the battery +lineDecoupling Via diodeDUT supply Max. 80V/30AFreestyle Mode Micropulses: Rise time 1us 10us - 90us with 10us steps 100us - 900us with 100us steps 1ms - 10ms with 1ms steps Pulse duration 10ms - 1,200ms Int. resistor 0.5ohm - 38ohm, in steps of 0.1ohmTest Standards: ISO 7637-2 Pulse 5b for 12V and 24V, ISO/WD 16750 Pulse 5b, and much moreTest Routines: Quick Start, User Defines Routines, Standards Test Routines Service$1,690.00 - $2,290.00Typically In Stock -
EM Test
SKU: sku-776
Rent EM Test TSS 500M2F Telecom Surge Simulator for FCC Part 68
Weight: approx. 35kgApplication/Test Type: Test levels as per FCC part 68Coupling: Telecom ports: Tip to Ground, Ring to Ground, Tip and Ring to Ground Power ports 250V/16A: L toN, L to PE, N to PE , L+N to PEDimensions: 19“ / 6HU,Output Current: 64A – 1,000A (power line) 20 – 200A per wire (surge A)Outputs: 4 mm banana socketPolarity: pos / neg / alternateRise time: Less than 2 usTelecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendationsTest Voltage: 160V – 2,500V ± 10% (power line) 160V – 1,500V ± 10% (surge A)Trigger of bursts: Automatic pulse release$0.00 -
EM Test
SKU: sku-549
EM Test PFS 503N32 Power Fail Simulator, 3-phase 3x480V AC (p-p) max. 32A
Weight: app. 28kg;Current Rating: Max. 32ADimensions: 19"/6 HUDips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29Frequency: 50Hz/60Hz, Single phase applicationOutput: 3-phase application L1, L2, L3, N and PE on the rear panel. 1-phase application L, N and PE on the front panelPeak current: Better than 500ARepetition rate: 0.01s to 9,999sRise time: Between 1us and 5us for abrupt changes, generator loaded with resistive loadSupply Voltage: 115V/230V; +10/-15%Test Voltage: 3x480V AC resp. 3x690V AC (L-L) 277V AC resp. 400V AC 360V DC resp. 600V DC (L-N)Trigger of bursts: Automatic$0.00 -
EM Test
SKU: sku-547
EM Test NX5 Compact EMC Generator for EFT/Burst, Surge & Power Fail up to 5.5 kV
Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & VariationsStandards Met: IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11Applications: Conducted Immunity Testing, CE Marking, Medical DevicesMax EUT Voltage (w/ Built in CDN): 300 VoltsMax EUT Current (w/ Built in CDN): 16 AmpsPeak inrush current capability: 500 Amps (up to 2.5 kA)EFT/Burst Pulse Output Capability: 5.5 kVCombination/Wave Surge Output Capability: 5 kVExternal Coupling: Data Lines (EFT & Surge), 3PH EUTDips, Interrupts & Variations: 16 Hz - 500 Hz and DCVideos: Voltage Dips, EFT Burst Testing$0.00INQUIRE -
EM Test
SKU: sku-479
EM Test PFM 200N100.1 Automotive Power Fail Simulator for Power Supply and Data Lines
Test Standards: LV 124/LV 148, LV 123$0.00INQUIRE