Voltage Dips & Interrupts Generators Test Equipment, Systems & Solutions
-
Noiseken VDS-2002 Voltage Dip and Swell Simulator
SKU: NO-VDS-2002
Compliant Standard: IEC 61000-4-11 (1994) 、IEC 61000-4-11 (2004) at Output voltage 0 to 100%Input voltage from EUT: AC100〜240V±10% 50/60HzInterface: Optical interface Optional optical converter RS-232 or USB selectionOperating temperature: 15〜35℃Operating humidity: 25〜75%R.H.External dimensions / Weight: (W)430 x (H)745 x (D)600mm(excluding protrusions) / approx.150kgPower consumption: 120VA (AC100〜240V 50/60Hz) -
3ctest PFS 2216SD Power Fail Simulator for EN/IEC 61000-4-11
SKU: sku-590
Test Standards: IEC/EN 61000-4-11, IEC/EN 61000-4-29Mains & EUT Connections: 4mm banana lineOutput Current: 16A AC/DC continuous current; 20A continuous 5s 40Acontinuous 3sPeak inrush current capability: 500 AmpsApplications: EMC Precompliance Testing, Conducted ImmunityRise time: 1-5us(100Ω load)Test duration: 50ms-50000msTest Voltage: 250V AC,300V DCTrigger: BNC,5V TTLInquire for Availability -
3ctest PFS 6030A Power Failure Simulator for Voltage Dips & Drops,60 V / 30 A
SKU: sku-588
Test voltage: Voltage drop: 1V max@30AWeight: 20 kgDimensions: 19" / 4 UOutput: DUT voltage monitoring output: BNC,10:1 coaxial terminal output DUT current monitoring output: BNC,10A:1V coaxial terminal outputPeak current: 60A duration time 500 msPulse duration: Drop duration time td 1us - 10 sRepetition rate: 100 ms - 999sSource Impedance: High resistance or low resistanceTest Voltage: 0–60 VTrigger: External trigger signal by oscilloscope, BNC,5V TTLTrigger of bursts: Automatic, manual, external -
Haefely PLINE 1610 Voltage Failure Simulator
SKU: 10503
Test Standards: IEC/EN 61000-4-11, IEC/EN 61000-4-29Voltage Range: 0 - 264 VoltsFrequency Range: 48 to 62 HzCurrent Range: up to 16A rms continuous, 20A @ 80%, 23A @ 70%, 40A @ 40%(rms for 5s)Phase synchronization: Synchronous 0 to 360 resolution, AsynchronousTest duration: 1s to 100 hoursTrigger: Auto, Manual, External$1,275.00 - $19,750.00Typically In Stock -
Teseq INA 6501 Manual Step Transformer for AC Dips & Interruptions
SKU: sku-116
Accuracy: ±5%Input voltage UIN: 0 to 250 VAC, 50/60 HzOutput voltage UVAR: 4 steps: 0% - 40% - 70% - 80% of UINVoltage change with load: 00% output, 0 to 16 A less than 5%; 80% output, 0 to 20 A less than 5%; 70% output, 0 to 23 A less than 5%; 40% output, 0 to 40 A less than 5%$2,060.00 -
Haefely DIP 116 Automatic Dips Transformer 16 Amps 40/70/80%
SKU: HAE-DIP116
Test Standards: IEC 61000-4-11Typically In Stock -
3ctest APS 40C20 Voltage Drop Simulator
SKU: sku-1684
Applications: Automotive EMCMax EUT DC Voltage (W/ Built In CDN): 40 VoltsMax EUT DC Current (W/ Built In CDN): 20 AmpsIN STOCK -
EM Test PFS 200N30 Simulator for DC Voltage Drops & Micro-interruptions
SKU: 2806
Applications: Automotive Power Fail Simulator For Voltage Dips and InterruptionsStandards Met: ISO 16750-2OEM Standards Met: BMW GS 95003-2, Fiat 9.90110, Ford EMC-CS-2009.1, GMW 3172, Hyundai Kia ES, IVECO 16-2103, Mack Trucks 606GS15, Mitsubishi ES-X82010, PSA B21 7110, Volvo STD 515-003, Ford FMC 1278, BMW GS 95024-2-2, Jaguar JLR-EMC-CS, Tesla TS-0000425-05Max EUT DC Voltage (W/ Built In CDN): 80 VoltsMax EUT DC Current (W/ Built In CDN): 30 AmpsPeak Inrush Current Capability: 70 Amps$459.00 - $1,095.00IN STOCK -
EM Test VDS 200N30 Voltage Drop Simulator
SKU: sku-1844
Applications: EMC Testing on EV Electric Vehicles Batteries & Charging Stations, Automotive Electrical DisturbancesStandards Met: ISO 7637 , FMC1278, & MoreMax EUT DC Voltage (W/ Built In CDN): 60 VoltsMax EUT DC Current (W/ Built In CDN): 30 AmpsRental Only -
3ctest PFS 6050A Automotive Power Failure Simulator
SKU: 3C-PFS6050A
Voltage Handling: 0 to 60 VTest Standards: LV 124, VW80000, GMW 3172, BMW GS 95003-2, Chrysler PF-9326, Cummins 14269(982022-026), DaimierChrysler DC-10842, Fiat 9.90110, Ford EMC-CS-2009.1, DaimlerChrysler PF-10541, Hyundai/Kia ES 96100-02, Hyundai ES 39110-00Peak current: 60A duration time 500 msApplications: Automotive EMC Testing$975.00 - $4,975.00In Stock -
AE Techron 4301 DC Voltage Variations and Telecom Transients Test System
SKU: 44557
Test Standards: GR-1089 Section 10 and ATIS-0600315.2007Maximum Continuous DC Current (±50 VDC): 60-240 Amps (model dependent)Maximum Pulse DC Current (up to ±100 VDC): 200-800 Amps (model dependent)Voltage Gain: 20Maximum Input Voltage: ±10V, unbalancedInquire for Availability -