Description
The FT 801 is recommended as an additional decoupling network (ferrite tube) for immunity test according to IEC / EN 61000-4-6 when using the clamp injection method. It shall be inserted on all the cables between EUT and AE except the cable under test. The FT 801 prevents, that the test signal applied to the EUT affects other devices, equipment or systems, which are not under test and improves the reproducibility of the test results.
The large inner diameter of the FT 801 allows threading of cables with connectors.
Specifications:
- Frequency range 150 kHz to 1000 MHz
- Insertion loss see graph
- Maximum cable diameter 35 mm
- Dimension (LxWxH) 670 mm x 70 mm x 80 mm
- Weight approx. 8 kg
Standards Met:
- IEC/EN 61000-4-6
- CISPR 24
- EN 61000-6-1
- EN 61000-6-2
- IEC 60533
- IEC 60601-1-2
- IEC 61326
Videos
Custom Field
Weight approx. 8 kg
Application/Test Type decoupling network (ferrite tube) for immunity test according to IEC / EN 61000-4-6
Dimensions 670 mm x 70 mm x 80 mm
Frequency Range 150 kHz to 1000 MHz
Max. Cable Diameter 35 mm
Standards Met IEC/EN 61000-4-6
CISPR 24
EN 61000-6-1
EN 61000-6-2
IEC 60533
IEC 60601-1-2
IEC 61326