sku: sku-2132 EMIC-35 Current Injection Clamp for RF Conducted Immunity Testing Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive coupling Frequency Range: 10 kHz to 1000 MHz Maximum Continuous Power: 0.15 to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 5 min; 230 to 1000 MHz: 50 W for 3 min Standards Met: IEC/EN 61000-4-6; CISPR 24; EN 61000-6-1; EN 61000-6-2; IEC 60533; IEC 60601-1-2; IEC 61326 Add to Cart
EM Test | sku: sku-1881 EM Test / Luthi EM 101 EM Injection Clamp for IEC/EN 61000-4-6 Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive coupling Frequency Range: 10 kHz to 1000 MHz Maximum Continuous Power: 0.01 to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 3 min; 230 to 1000 MHz: 50 W for 3 min Standards Met: IEC/EN 61000-4-6; CISPR 24; EN 61000-6-1; EN 61000-6-2; IEC 60533; IEC 60601-1-2; IEC 61326 Add to Cart
Teseq | sku: sku-1038 Montly Rental TESEQ AMZ 41 Absorbing Clamp for CISPR 13 & 14, w/ LE 210 RF Cable Add to Cart
FCC | sku: sku-726 Fischer Custom Communications F-203I-A-23MM, 10kHz - 1GHz, 100 Watts CW Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive coupling Frequency Range: 10kHz - 1GHz Maximum Continuous Power: 100 watts CW for 15 minutes Standards Met: IEC/EN 61000-4-6; Add to Cart
Teseq | sku: sku-673 Teseq FT 801 Ferrit Tube EM Decoupling Clamp, 150 kHz to 1 GHz, 35 mm Cable Diameter Application/Test Type: decoupling network (ferrite tube) for immunity test according to IEC / EN 61000-4-6 Frequency Range: 150 kHz to 1000 MHz Standards Met: IEC/EN 61000-4-6 CISPR 24 EN 61000-6-1 EN 61000-6-2 IEC 60533 IEC 60601-1-2 IEC 61326 Add to Cart
Teseq | sku: sku-559 Teseq MDS 21B EMC Absorbing Clamp for Disturbance Power Measuring, w/ 6 dB Attenuator & RF Cable Frequency Range: 30 MHz to 1000 MHz Add to Cart
Schloder | sku: sku-525 Schloder CDN-EMCL-35 Current Injection Clamp for RF Conducted Immunity Testing Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive coupling Frequency Range: 10 kHz to 1000 MHz Maximum Continuous Power: 0.15 to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 5 min; 230 to 1000 MHz: 50 W for 3 min Standards Met: IEC/EN 61000-4-6; CISPR 24; EN 61000-6-1; EN 61000-6-2; IEC 60533; IEC 60601-1-2; IEC 61326 Add to Cart
sku: sku-524 EMIC-20 EM Injection Clamp for IEC/EN 61000-4-6 Immunity Test Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive coupling Frequency Range: 10 kHz to 1000 MHz Maximum Continuous Power: 0.15 to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 5 min; 230 to 1000 MHz: 50 W for 3 min Standards Met: IEC/EN 61000-4-6; CISPR 24; EN 61000-6-1; EN 61000-6-2; IEC 60533; IEC 60601-1-2; IEC 61326 Add to Cart
sku: sku-266 Com-Power CLA-150 32mm Absorbing Clamp Aperture: 34.9 mm (1.37 inches) Application/Test Type: Measurement of direct field strength from EUT supply cables Frequency Range: 30 MHz to 1000 MHz Standards Met: CISPR 14 Choose Options
Teseq | sku: sku-1038 Montly Rental TESEQ AMZ 41 Absorbing Clamp for CISPR 13 & 14, w/ LE 210 RF Cable View Details
FCC | sku: sku-726 Fischer Custom Communications F-203I-A-23MM, 10kHz - 1GHz, 100 Watts CW View Details
Teseq | sku: sku-673 Teseq FT 801 Ferrit Tube EM Decoupling Clamp, 150 kHz to 1 GHz, 35 mm Cable Diameter View Details
Teseq | sku: sku-559 Teseq MDS 21B EMC Absorbing Clamp for Disturbance Power Measuring, w/ 6 dB Attenuator & RF Cable View Details
Schloder | sku: sku-525 Schloder CDN-EMCL-35 Current Injection Clamp for RF Conducted Immunity Testing View Details