Radiated Immunity Test Systems Test Equipment, Systems & Solutions
-
AR AS01018 Electromagnetic Field Immunity Test System
SKU: sku-2177
Generic Standards: IEC 61000-6-1, IEC 61000-6-2Test Standards: IEC 61000-4-3Frequency Range: 80 MHz - 6 GHzField Strength: up to 30 V/mTypically In Stock -
AR 1 GHz Radio Frequency Immunity Test Rack
SKU: sku-2176
Test Standards: IEC 61000-4-3Frequency Range: 80 MHz - 1 GHzField Strength: up to 100 V/mGeneric Standards: IEC 61000-6-1, IEC 61000-6-2In Stock -
Radiated Immunity Test System
SKU: 10019
Frequency Range: 80 MHz - 18 GHzCW Field Strength Levels (@ 3m): 60V/m (30 V/m w/ 80% AM)CW Field Strength Levels (@ 1m): 200 V/mTest Standards: IEC/EN 61000-4-3,MIL-STD 461 RS103, DO-160 Section 20, ISO 11452-2Applications: Radiated Immunity & SusceptibilityShipping: Setup and Configured in 1-2 WeeksGeneric Standards: IEC 61000-6-1, IEC 61000-6-24-6 Weeks -
Narda PMM Rad-IS RF Radiated Immunity System for IEC/EN 61000-4-3
SKU: sku-419
Application/Test Type: Compliance verification as for Standard IEC/EN 61000-4-3Connector: BNC Input, Output Type N(f)Frequency Range: 9 kHz to 3 GHzImpedance: 50 OhmsInput: 115/230 V 50/60 HzStandards Met: IEC 61000-4-3 -
Radiated Immunity Test System for IEC 61000-4-20 TEM Waveguides
SKU: sku-393
Application/Test Type: IEC 61000-4-20Frequency Range: 30 to 1000 MHzMax Radiated Field Strength: Lowest field strength: 1 V/m at 600 mm septum height* Highest field strength: approx. 18 V/m at 600 mm septum height*Maximum Continuous Power: Lowest forward power: 15 dBm* Highest forward power: 41 dBm* -
EFG-40G High-Frequency E-Field Generator
SKU: sku-1750-1
Top End Frequency: 40.0 GHzBottom End Frequency: 26.5 GHzGain: 35 dBTest Standards: MIL-STD-461 RS103, DO-160Output Power: 50 V/m at 1 meterInput Voltage: 100 - 240 VAC ±10% 50/60 HzReturn Loss: 10 dBStandards: MIL-STD-461Rentals Ship Today -
Teseq ITS 6006 Radiated Immunity Test System
SKU: sku-1290
Frequency Range: 80 MHz to 6 GHzInput: External AM input: BNC socket, impedance more than 10 kΩ External PM input: BNC socket, TTLOutput: Generator outputs: 4x N sockets 50 Ω, 80 MHz to 6 GHz Interlock outputs: 4x BNC sockets External PM output: BNC socket, TTL, impedance more than 1.2 kΩ 10 MHz reference output: BNC socket, approx. 0 dBm/50 ΩReference frequency: 10 MHzMax. adjustment deviation: ±50 Hz$18,000.00In Stock -
-
Teseq ITS 6006B Radiated Immunity Test System 80 MHz to 6 GHz
SKU: sku-498
Frequency Range: 80 MHz to 6 GHzInput: External AM input: BNC socket, impedance more than 10 kΩ External PM input: BNC socket, TTLOutput: Generator outputs: 4x N sockets 50 Ω, 80 MHz to 6 GHz Interlock outputs: 4x BNC sockets External PM output: BNC socket, TTL, impedance more than 1.2 kΩ 10 MHz reference output: BNC socket, approx. 0 dBm/50 Ω -